Design of supersensitive and selective ZnO-nanofiber-based sensors for H2 gas sensing by electron-beam irradiation
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In the present study, ZnO nanofibers (NFs) were synthesized by the simple electrospinning technique for gas sensing studies. ZnO NFs were irradiated with a high-energy (1 MeV) electron beam (e-beam) at different doses (50, 100, and 150 kGy) to study the effect of the e-beam dose on the sensing performance of the synthesized ZnO NFs. H2 sensing studies showed that the sensing properties of the unirradiated and 50 kGy-irradiated sensors were similar, which indicates that this e-beam dose was insufficient. However, the sensing characteristics improved with an increase in the irradiation dose to 100 and 150 kGy. The response of the optimal sensor (150-kGy-irradiated) to 10 ppm H2 was much higher than that to other (interfering) gases (e.g., C2H5OH, C6H6, C7H8, and CO). The observed high gas response of the 150 kGy-irradiated sensor was attributed to its high surface area resulting from the one-dimensional nature of the ZnO NFs, the grain size of ZnO, and the formation of surface defects by e-beam irradiation. The high selectivity of the ZnO NFs toward H2 gas was related mainly to the metallization of ZnO and the concentration gradient of carfbon across the NF surfaces. Overall, the findings demonstrate the effectiveness of high-energy irradiation in enhancing the sensing performance of ZnO NFs. We believe that this approach can be extended to other metal oxides for the enhancement of sensing performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cleaning the air and improving health with hydrogen fuel-cell vehicles
Jacobson, M. Z., Colella, W. G., & Golden, D. M. (2005) · Science · doi:10.1126/science.1109157 · Cited by 1,023
Cited by
Sensing advancement towards safety assessment of hydrogen fuel cell vehicles
Foorginezhad, S., Mohseni-Dargah, M., Falahati, Z., Abbassi, R., Razmjou, A., & Asadnia, M. (2021) · Journal of Power Sources · doi:10.1016/j.jpowsour.2021.229450 · Cited by 177
Down to ppb level NO2 detection by ZnO/rGO heterojunction based chemiresistive sensors
Cao, P., Cai, Y., Pawar, D., Navale, S. T., Rao, C. N., Han, S., Xu, W., Fang, M., Liu, X., Zeng, Y., et al. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.125491 · Cited by 159
Lee, J.-H., Kim, J.-H., Kim, J.-Y., Mirzaei, A., Kim, H. W., & Kim, S. S. (2019) · Sensors · doi:10.3390/s19194276 · Cited by 73
Self-citation
Metadata
- Authors
- Kim, J.-H., Mirzaei, A., Woo Kim, H., Wu, P., & Kim, S. S.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 293
- Pages
- 210-223
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W2943726244
- Cited by
- 158
- References
- 1
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.