Surface plasmon resonance biosensor for the detection of tau-amyloid β complex
The DOI matches its Crossref record.
Abstract
The development of methods advancing the understanding of molecular processes related to Alzheimer’s disease (AD) and detection of biomarkers of AD presents an important research goal. We present a new biosensor-based method for the detection of a prospective biomarker of AD, the complex of protein tau and amyloid β (tau-Aβ). The detection method combines a new sandwich assay incorporating functionalized gold nanoparticles (AuNPs) with a surface plasmon resonance (SPR) biosensor. We optimize the assay with respect to the functionalization of the sensor surface and the choice of AuNPs and show that the sensor allows for the detection of the tau-Aβ complex in cerebrospinal fluid (CSF) with the limit of detection of 1 pM. We also present the results of a preliminary study in which we use the method to detect tau-Aβ complex in CSF samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical Applications of Functionalized Gold Nanoparticles: A Review
Nejati, K., Dadashpour, M., Gharibi, T., Mellatyar, H., & Akbarzadeh, A. (2022) · Journal of Cluster Science · doi:10.1007/s10876-020-01955-9 · Cited by 286
Gold nanoparticles (AuNPs): A versatile material for biosensor application
Kumalasari, M. R., Alfanaar, R., & Andreani, A. S. (2024) · Talanta Open · doi:10.1016/j.talo.2024.100327 · Cited by 244
Lopes, L. C., Santos, A., & Bueno, P. R. (2022) · Sensors and Actuators Reports · doi:10.1016/j.snr.2022.100087 · Cited by 91
Current trends in blood biomarker detection and imaging for Alzheimer’s disease
Hu, S., Yang, C., & Luo, H. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114278 · Cited by 84
Moorthy, H., & Govindaraju, T. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01319 · Cited by 64
Metadata
- Authors
- Špringer, T., Hemmerová, E., Finocchiaro, G., Krištofiková, Z., Vyhnálek, M., & Homola, J.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 316
- Pages
- 128146
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3017790492
- Cited by
- 61
- References
- 0
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface plasmon resonance biosensor for the detection of tau-amyloid β complex. https://app.cochat.ai/papers/10.1016/j.snb.2020.128146
- The paper
- Špringer, T., Hemmerová, E., Finocchiaro, G., Krištofiková, Z., Vyhnálek, M., & Homola, J. (2020). Surface plasmon resonance biosensor for the detection of tau-amyloid β complex. Sensors and Actuators B: Chemical. https://doi.org/10.1016/j.snb.2020.128146
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.