An outlook on electrochemical approaches for molecular diagnostics assays and discussions on the limitations of miniaturized technologies for point-of-care devices
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The detection of specific biomarkers for health monitoring, i.e., molecular diagnostics, can be classified as early or emergency diagnostics. Emergency diagnostics is related to those diseases which is necessary a rapid patient intervention, such as stroke and cardiac attack, in addition to the detection of infectious diseases to monitor and control outbreaks and epidemics, and early diagnosis requires the highly sensitive quantification of the biomarkers related to, specially, degenerative and cancer diseases for a successful treatment. Herein, the challenges of designing improved point-of-care (PoC) molecular diagnostic devices were reviewed, and the limitations of standard technologies were discussed. Despite their high sensitivities, precisions, and reliabilities, standard technologies are still limited by their requirements for expensive reagents and equipment, as well as laborious and time-consuming sample pretreatments, elaborate protocols, and qualified personnel, which highly impact their applications in loco and affordability. PoC assays exhibiting high selectivity and portability have been demonstrated feasibility in biosensing technologies. To explore the biosensor application regarding the limitations of achieving the commercialization of these technologies, the strategies for developing label-based and label-free biosensors will be discussed as they relate to the types of bioreceptor and the signal transduction methods. Electrochemical biosensors will especially be focused on because of their advantages, such as scalability, miniaturization, and sensitivity (with some electrochemical biosensing setups not requiring complex steps, such as sample pretreatment, to complete the diagnostics, thus availing reliable PoC analysis). Further, the challenges of developing reliable commercial PoC devices will be discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Specific Enzymatic Amplification of DNA In Vitro: The Polymerase Chain Reaction
Mullis, K., Faloona, F., Scharf, S., Saiki, R., Horn, G., & Erlich, H. (1986) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1986.051.01.032 · Cited by 3,558
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
A dielectric-modulated field-effect transistor for biosensing
Im, H., Huang, X.-J., Gu, B., & Choi, Y.-K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.180 · Cited by 635
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results
Tonyushkina, K., & Nichols, J. H. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300446 · Cited by 406
C-reactive protein and Hypertension
Hage, F. G. (2014) · Journal of Human Hypertension · doi:10.1038/jhh.2013.111 · Cited by 205
Avan, A., Tavakoly Sany, S. B., Ghayour‐Mobarhan, M., Rahimi, H. R., Tajfard, M., & Ferns, G. (2018) · Journal of Cellular Physiology · doi:10.1002/jcp.26791 · Cited by 182
Futuristic biosensors for cardiac health care: an artificial intelligence approach
Vashistha, R., Dangi, A. K., Kumar, A., Chhabra, D., & Shukla, P. (2018) · 3 Biotech · doi:10.1007/s13205-018-1368-y · Cited by 113
Research works printed but not linked: 149
- Castillo, 2004, Biosensors for life quality: design, development and applications, Sens. Actuators B, 102, 179, 10.1016/j.snb.2004.04.084 · DOI · Paper page
- Sankaran, 2010, A review of advanced techniques for detecting plant diseases, Comput. Electron. Agric., 72, 1, 10.1016/j.compag.2010.02.007 · DOI
- Uyttendaele, 2016, Food safety, a global challenge, Int. J. Environ. Res. Public Health, 13, 67, 10.3390/ijerph13010067 · DOI · Paper page
- Sidhu, 2019, Toxicity, monitoring and biodegradation of organophosphate pesticides: a review, Crit. Rev. Environ. Sci. Technol., 49, 1135, 10.1080/10643389.2019.1565554 · DOI · Paper page
- Hussain, 2013, Economic impact of food safety outbreaks on food businesses, Foods, 2, 585, 10.3390/foods2040585 · DOI · Paper page
- Qureshi, 2012, Biosensors for cardiac biomarkers detection: a review, Sens. Actuators B, 171–172, 62, 10.1016/j.snb.2012.05.077 · DOI · Paper page
- Group, 2001, Biomarkers and surrogate endpoints: Preferred definitions and conceptual framework, Clin. Pharmacol. Ther., 69, 89, 10.1067/mcp.2001.113989 · DOI · Paper page
- Pejcic, 2006, The role of biosensors in the detection of emerging infectious diseases, Analyst, 131, 1079, 10.1039/b603402k · DOI · Paper page
- Spinelli, 2020, COVID-19 pandemic: perspectives on an unfolding crisis, BJS Br. J. Surg., 10.1002/bjs.11627 · DOI · Paper page
- Peng, 2021, An electrochemical biosensor for sensitive analysis of the SARS-CoV-2 RNA, Biosens. Bioelectron., 186, 10.1016/j.bios.2021.113309 · DOI
- Chu, 2021, Recent advances and challenges of biosensing in point-of-care molecular diagnosis, Sens. Actuators B Chem., 348, 10.1016/j.snb.2021.130708 · DOI
- Oellerich, 1980, Enzyme immunoassays in clinical chemistry: present status and trends, Clin. Chem. Lab. Med. (CCLM), 18, 197, 10.1515/cclm.1980.18.4.197 · DOI · Paper page
- Wilson, 2006, The novel role of C-reactive protein in cardiovascular disease: risk marker or pathogen, Int. J. Cardiol., 106, 291, 10.1016/j.ijcard.2005.01.068 · DOI · Paper page
- Turner, 1999, In vitro diagnostics in diabetes: meeting the challenge, Clin. Chem., 45, 1596, 10.1093/clinchem/45.9.1596 · DOI · Paper page
- Khan, 1996, Design of a stable charge transfer complex electrode for a third-generation amperometric glucose sensor, Anal. Chem., 68, 2939, 10.1021/ac9510393 · DOI · Paper page
- Kirsch, 2013, Biosensor technology: recent advances in threat agent detection and medicine, Chem. Soc. Rev., 42, 8733, 10.1039/c3cs60141b · DOI · Paper page
- Zhang, 2016, Biosensors and bioelectronics on smartphone for portable biochemical detection, Biosens. Bioelectron., 75, 273, 10.1016/j.bios.2015.08.037 · DOI · Paper page
- Pingarrón, 2008, Gold nanoparticle-based electrochemical biosensors, Electrochim. Acta, 53, 5848, 10.1016/j.electacta.2008.03.005 · DOI · Paper page
- Syahir, 2015, Label and label-free detection techniques for protein microarrays, Microarrays, 4, 228, 10.3390/microarrays4020228 · DOI · Paper page
- Wang, 2006, Electrochemical biosensors: Towards point-of-care cancer diagnostics, Biosens. Bioelectron., 21, 1887, 10.1016/j.bios.2005.10.027 · DOI · Paper page
- Tkac, 2009, Chapter 7 label-free field effect protein sensing, 193
- Perumal, 2014, Advances in biosensors: Principle, architecture and applications, J. Appl. Biomed., 12, 1, 10.1016/j.jab.2013.02.001 · DOI · Paper page
- Li, 2008, Electrochemical impedance spectroscopy for study of aptamer–thrombin interfacial interactions, Biosens. Bioelectron., 23, 1624, 10.1016/j.bios.2008.01.029 · DOI · Paper page
- Ronkainen, 2010, Electrochemical biosensors, Chem. Soc. Rev., 39, 1747, 10.1039/b714449k · DOI · Paper page
- Florea, 2019, Electrochemical biosensors as potential diagnostic devices for autoimmune diseases, Biosensors, 9, 38, 10.3390/bios9010038 · doi:10.3390/bios9010038
- Chen, 2020, Optical biosensors: an exhaustive and comprehensive review, Analyst, 145, 1605, 10.1039/C9AN01998G · DOI · Paper page
- Liu, 2015, Surface plasmon resonance biosensor based on smart phone platforms, Sci. Rep., 5, 12864, 10.1038/srep12864 · doi:10.1038/srep12864
- Singh, 2016, Historical Perspectives and current challenges, Sens. Actuators B, 229, 110, 10.1016/j.snb.2016.01.118 · DOI · Paper page
- Zhao, 2019, Current status of optical fiber biosensor based on surface plasmon resonance, Biosens. Bioelectron., 142, 10.1016/j.bios.2019.111505 · DOI · Paper page
- Speight, 2012, A survey of the 2010 quartz crystal microbalance literature, J. Mol. Recognit., 25, 451, 10.1002/jmr.2209 · DOI
- Länge, 2019, Bulk and surface acoustic wave sensor arrays for multi-analyte detection: a review, Sensors, 19, 5382, 10.3390/s19245382 · DOI
- Pohanka, 2018, Overview of piezoelectric biosensors, immunosensors and DNA sensors and their applications, Materials, 11, 448, 10.3390/ma11030448 · DOI · Paper page
- Zhang, 2004, Calorimetric biosensors with integrated microfluidic channels, Biosens. Bioelectron., 19, 1733, 10.1016/j.bios.2004.01.009 · doi:10.1016/j.bios.2004.01.009
- Mehrvar, 2004, Recent developments, characteristics, and potential applications of electrochemical biosensors, Anal. Sci. Int. J. Jpn. Soc. Anal. Chem., 20, 1113, 10.2116/analsci.20.1113 · DOI · Paper page
- Spink, 1976, Calorimetry as an analytical tool in biochemistry and biology, Methods Biochem Anal, 23, 1
- Gaudin, 2016, Advances in biosensor development for the screening of antibiotic residues in food products of animal origin – a comprehensive review, Biosens. Bioelectron., 90
- Ramanathan, 1999, The development and applications of thermal biosensors for bioprocess monitoring, Trends Biotechnol., 17, 499, 10.1016/S0167-7799(99)01378-5 · DOI
- Szakmany, 2014, Single-metal nanoscale thermocouples, IEEE Trans. Nanotechnol., 13, 1234, 10.1109/TNANO.2014.2358532 · doi:10.1109/tnano.2014.2358532
- Wang, 2018, Manufacturing and characterization of simple cantilever thermal biosensor with Si-Metal thermocouple structure for enzymatic reaction detection, Thermochim. Acta, 668, 110, 10.1016/j.tca.2018.08.020 · doi:10.1016/j.tca.2018.08.020
- Zhang, 2019, Chapter 6 - mechanical transducers: cantilevers, acoustic wave sensors, and thermal sensors, 311
- Mattiasson, 1977, Thermometric enzyme linked immunosorbent assay: TELISA, Biochim. Biophys. Acta, 483, 221, 10.1016/0005-2744(77)90050-X · doi:10.1016/0005-2744(77)90050-x
- Xu, 2017, Pretreatment-free detection of diazepam in beverages based on a thermometric biosensor, Sens. Actuators B, 241, 504, 10.1016/j.snb.2016.10.081 · DOI
- Zourob M. “Recognition receptors in Biosensors” ISBN 978-1-4419-0918-3. Springer science+ business media; 2010.
- Khan, 2014, Luminol-based chemiluminescent signals: clinical and non-clinical application and future uses, Appl. Biochem. Biotechnol., 173, 333, 10.1007/s12010-014-0850-1 · DOI · Paper page
- Baeyens, 1998, Chemiluminescence-based detection: principles and analytical applications in flowing streams and in immunoassays, J. Pharm. Biomed. Anal., 17, 941, 10.1016/S0731-7085(98)00062-4 · doi:10.1016/s0731-7085(98)00062-4
- Lin, 2018, A turn-on chemiluminescence biosensor for selective and sensitive detection of adenosine based on HKUST-1 and QDs-luminol-aptamer conjugates, Talanta, 182
- Costa, 2018, Microfluidic chemiluminescence system with yeast saccharomyces cerevisiae for rapid biochemical oxygen demand measurement, ACS Sustain. Chem. Eng., 6
- Cinquanta, 2017, Chemiluminescent immunoassay technology: what does it change in autoantibody detection?, Auto Immun. Highlights, 8
- Kricka, 2003, Clinical applications of chemiluminescence, Anal. Chim. Acta, 500, 279, 10.1016/S0003-2670(03)00809-2 · DOI · Paper page
- Al Mughairy, 2020, Recent analytical advancements in microfluidics using chemiluminescence detection systems for food analysis, TrAC Trends Anal. Chem., 124, 10.1016/j.trac.2019.115802 · DOI
- Sauerbrey, 1959, Verwendung von schwingquarzen zur wägung dünner schichten und zur mikrowägung, Z. Physik, 155, 206, 10.1007/BF01337937 · DOI · Paper page
- Uludag, 2012, Cancer biomarker detection in serum samples using surface plasmon resonance and quartz crystal microbalance sensors with nanoparticle signal amplification, Anal. Chem., 84, 5898, 10.1021/ac300278p · DOI · Paper page
- Pesquero, 2010, Real-time monitoring and kinetic parameter estimation of the affinity interaction of jArtinM and rArtinM with peroxidaseglycoprotein by the electrogravimetric technique, Biosens. Bioelectron., 26, 36, 10.1016/j.bios.2010.04.047 · doi:10.1016/j.bios.2010.04.047
- Li, 2019, Advances in molecularly imprinting technology for bioanalytical applications, Sensors, 19, 177, 10.3390/s19010177 · doi:10.3390/s19010177
- Tai, 2006, Artificial receptors in serologic tests for the early diagnosis of dengue virus infection, Clin. Chem., 52, 1486, 10.1373/clinchem.2005.064501 · doi:10.1373/clinchem.2005.064501
- Peduru Hewa, 2009, The detection of influenza A and B viruses in clinical specimens using a quartz crystal microbalance, J. Virol. Methods, 162, 14, 10.1016/j.jviromet.2009.07.001 · doi:10.1016/j.jviromet.2009.07.001
- Dotis, 2009, H1N1 influenza A infection, Hippokratia, 13, 135
- Zuo, 2004, Piezoelectric immunosensor for SARS-associated coronavirus in sputum, Anal. Chem., 76, 3536, 10.1021/ac035367b · DOI
- Abdul Rasheed, 2016, Quartz crystal microbalance genosensor for sequence specific detection of attomolar DNA targets, Anal. Chim. Acta, 905, 134, 10.1016/j.aca.2015.11.033 · DOI
- Long, 2013, Recent advances in optical biosensors for environmental monitoring and early warning, Sensors, 13, 10.3390/s131013928 · DOI · Paper page
- Masson, 2017, Surface plasmon resonance clinical biosensors for medical diagnostics, ACS Sens., 2, 16, 10.1021/acssensors.6b00763 · DOI · Paper page
- Safina, 2011, Surface plasmon resonance for real-time study of lectin–carbohydrate interactions for the differentiation and identification of glycoproteins, Talanta, 84, 1284, 10.1016/j.talanta.2011.01.030 · doi:10.1016/j.talanta.2011.01.030
- Campbell, 2007, SPR microscopy and its applications to high-throughput analyses of biomolecular binding events and their kinetics, Biomaterials, 28, 2380, 10.1016/j.biomaterials.2007.01.047 · DOI · Paper page
- Sharma, 2021, Surface plasmon resonance sensing of Ebola virus: a biological threat, Anal. Bioanal.Chem., 12
- Abdulhalim, 2008, Surface plasmon resonance for biosensing: a mini-review, Electromagnetics, 28, 214, 10.1080/02726340801921650 · DOI · Paper page
- Mayer, 2011, Localized surface plasmon resonance sensors, Chem. Rev., 111, 3828, 10.1021/cr100313v · DOI · Paper page
- Špringer, 2014, Enhancing sensitivity of surface plasmon resonance biosensors by functionalized gold nanoparticles: size matters, Anal. Chem., 86, 10350, 10.1021/ac502637u · DOI · Paper page
- Vashist, 2015, Surface plasmon resonance-based immunoassay for human C-reactive protein, Analyst, 140, 4445, 10.1039/C5AN00690B · DOI
- Liu, 2011, Surface plasmon resonance biosensor with high anti-fouling ability for the detection of cardiac marker troponin T, Anal. Chim. Acta, 703, 80, 10.1016/j.aca.2011.07.019 · DOI
- Špringer, 2020, Surface plasmon resonance biosensor for the detection of tau-amyloid β complex, Sens. Actuators B, 316, 10.1016/j.snb.2020.128146 · DOI · Paper page
- Wang, 2016, Surface plasmon resonance biosensor for enzyme-free amplified microRNA detection based on gold nanoparticles and DNA supersandwich, Sens. Actuators B, 223, 613, 10.1016/j.snb.2015.09.152 · DOI
- Wang, 2021, Recent progress of surface plasmon resonance in the development of coronavirus disease-2019 drug candidates, Eur. J. Med. Chem. Rep., 1
- Chillawar, 2015, Voltammetric techniques at chemically modified electrodes, J. Anal. Chem., 70, 399, 10.1134/S1061934815040152 · doi:10.1134/s1061934815040152
- Ramaley, 1969, Theory of square wave voltammetry, Anal. Chem., 41, 1362, 10.1021/ac60280a005 · doi:10.1021/ac60280a005
- Chen, 2013, Electrochemical sensing and biosensing based on square wave voltammetry, Anal. Methods, 5, 2158, 10.1039/c3ay40155c · DOI · Paper page
- Mahari, 2020, eCovSens-ultrasensitive novel in-house built printed circuit board based electrochemical device for rapid detection of nCOVID-19 antigen, a spike protein domain 1 of SARS-CoV-2, bioRxiv
- Rezaei, 2019, Chapter 2 - electrochemical detection techniques in biosensor applications, 11
- Johnson, 2014, Understanding enzymatic acceleration at nanoparticle interfaces: approaches and challenges, Nano Today, 9, 102, 10.1016/j.nantod.2014.02.005 · DOI · Paper page
- Pisoschi, 2014, Biosensors as bio-based materials in chemical analysis: a review, ChemInform, 45
- Yunus, 2011, A method to probe electrochemically active material state in portable sensor applications, Sens. Actuators B, 156, 35, 10.1016/j.snb.2011.03.070 · doi:10.1016/j.snb.2011.03.070
- Pohanka, 2008, Electrochemical biosensors - principles and applications, J. Appl. Biomed., 6, 57, 10.32725/jab.2008.008 · DOI · Paper page
- Laboria, 2010, Amperometric Immunosensor for carcinoembryonic antigen in colon cancer samples based on monolayers of dendritic bipodal scaffolds, Anal. Chem., 82, 1712, 10.1021/ac902162e · DOI
- Mathur, 2013, Development of a biosensor for detection of pleural mesothelioma cancer biomarker using surface imprinting, PLoS One, 8, 10.1371/journal.pone.0057681 · DOI
- Chen, 2011, Silicon nanowire field-effect transistor-based biosensors for biomedical diagnosis and cellular recording investigation, Nano Today, 6, 131, 10.1016/j.nantod.2011.02.001 · DOI · Paper page
- Goda, 2013, Label-free and reagent-less protein biosensing using aptamer-modified extended-gate field-effect transistors, Biosens. Bioelectron., 45, 89, 10.1016/j.bios.2013.01.053 · DOI
- Kim, 2013, CRP detection from serum for chip-based point-of-care testing system, Biosens. Bioelectron., 41, 322, 10.1016/j.bios.2012.08.047 · DOI
- Huang, 2013, Real-time and label-free detection of the prostate-specific antigen in human serum by a polycrystalline silicon nanowire field-effect transistor biosensor, Anal. Chem., 85, 7912, 10.1021/ac401610s · DOI
- Vu, 2019, Field-effect transistor biosensors for biomedical applications: recent advances and future prospects, Sensors, 19, 4214, 10.3390/s19194214 · DOI · Paper page
- Seo, 2020, Rapid detection of COVID-19 causative virus (SARS-CoV-2) in human nasopharyngeal swab specimens using field-effect transistor-based biosensor, ACS Nano, 14, 5135, 10.1021/acsnano.0c02823 · DOI · Paper page
- Esteban, 1991, On the application of the Kramers-Kronig relations to evaluate the consistency of electrochemical impedance data, J. Electrochem. Soc., 138, 67, 10.1149/1.2085580 · doi:10.1149/1.2085580
- Liu, 2016, Biosensors based on modularly designed synthetic peptides for recognition, detection and live/dead differentiation of pathogenic bacteria, Biosens. Bioelectron., 80, 9, 10.1016/j.bios.2016.01.041 · DOI
- Janek, 1998, Impedance spectroscopy of self-assembled monolayers on Au(111): sodium ferrocyanide charge transfer at modified electrodes, Langmuir, 14, 3011, 10.1021/la970980+ · doi:10.1021/la970980+
- Hou, 2005, Study of mixed Langmuir-Blodgett films of immunoglobulin G/amphiphile and their application for immunosensor engineering, Biosens. Bioelectron., 20, 1126, 10.1016/j.bios.2004.05.017 · doi:10.1016/j.bios.2004.05.017
- Tuteja, 2016, A label-free electrochemical immunosensor for the detection of cardiac marker using graphene quantum dots (GQDs), Biosens. Bioelectron., 86, 548, 10.1016/j.bios.2016.07.052 · DOI · Paper page
- Luo, 2013, Electrical biosensors and the label free detection of protein disease biomarkers, Chem. Soc. Rev., 42, 5944, 10.1039/c3cs60077g · DOI · Paper page
- Daniels, 2007, Label-free impedance biosensors: opportunities and challenges, Electroanalysis, 19, 1239, 10.1002/elan.200603855 · DOI · Paper page
- Lisdat, 2008, The use of electrochemical impedance spectroscopy for biosensing, Anal. Bioanal.Chem., 391, 1555, 10.1007/s00216-008-1970-7 · DOI · Paper page
- K'Owino, 2005, Impedance spectroscopy: a powerful tool for rapid biomolecular screening and cell culture monitoring, Electroanalysis, 17, 2101, 10.1002/elan.200503371 · DOI · Paper page
- Santos, 2014, Fundamentals and applications of impedimetric and redox capacitive biosensors, J. Anal. Bioanal. Tech., 0
- Contreras Jiménez, 2015, Aptamer-based label-free impedimetric biosensor for detection of progesterone, Anal. Chem., 87, 1075, 10.1021/ac503639s · DOI
- Johnson, 2012, Sensitive affimer and antibody based impedimetric label-free assays for C-reactive protein, Anal. Chem., 84, 6553, 10.1021/ac300835b · DOI
- Khan, 2020, Ultrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art, Biosens. Bioelectron., 166, 10.1016/j.bios.2020.112431 · DOI · Paper page
- Loeffelholz, 2020, Laboratory diagnosis of emerging human coronavirus infections — the state of the art, Emerg. Microb. Infect., 9, 1, 10.1080/22221751.2020.1745095 · DOI · Paper page
- Berggren, 2001, Capacitive biosensors, Electroanalysis, 13, 173, 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO;2-B · doi:10.1002/1521-4109(200103)13:3<173::aid-elan173>3.0.co;2-b
- Goes, 2012, A dielectric model of self-assembled monolayer interfaces by capacitive spectroscopy, Langmuir, 28, 9689, 10.1021/la301281y · doi:10.1021/la301281y
- Garrote, 2019, Perspectives on and precautions for the uses of electric spectroscopic methods in label-free biosensing applications, ACS Sens, 4, 2216, 10.1021/acssensors.9b01177 · DOI
- Fernandes, 2014, Comparing label free electrochemical impedimetric and capacitive biosensing architectures, Biosens. Bioelectron., 57, 96, 10.1016/j.bios.2014.01.044 · DOI
- Bryan, 2013, An optimised electrochemical biosensor for the label-free detection of C-reactive protein in blood, Biosens. Bioelectron., 39, 94, 10.1016/j.bios.2012.06.051 · DOI · Paper page
- Piccoli, 2016, The self-assembly of redox active peptides: Synthesis and electrochemical capacitive behavior, Pept. Sci., 106, 357, 10.1002/bip.22815 · doi:10.1002/bip.22815
- Bueno, 2014, Measuring Quantum capacitance in energetically addressable molecular layers, Anal. Chem., 86, 1337, 10.1021/ac403135b · doi:10.1021/ac403135b
- Fernandes, 2013, Label free redox capacitive biosensing, Biosens. Bioelectron., 50, 437, 10.1016/j.bios.2013.06.043 · DOI
- Schöning, 2018, Label-free biosensing: advanced materials, Devices Appl.
- Liu, 2017, Label and label-free based surface-enhanced Raman scattering for pathogen bacteria detection: a review, Biosens. Bioelectron., 94, 131, 10.1016/j.bios.2017.02.032 · DOI · Paper page
- Bahadır, 2015, Applications of commercial biosensors in clinical, food, environmental, and biothreat/biowarfare analyses, Anal. Biochem., 478, 107, 10.1016/j.ab.2015.03.011 · DOI · Paper page
- Ho, 2010, Diagnostic detection of human lung cancer-associated antigen using a gold nanoparticle-based electrochemical immunosensor, Anal. Chem., 82, 5944, 10.1021/ac1001959 · doi:10.1021/ac1001959
- Zhou, 2014, An ultrasensitive electrochemical immunosensor for carcinoembryonic antigen detection based on staphylococcal protein A—Au nanoparticle modified gold electrode, Sens. Actuators B, 197, 220, 10.1016/j.snb.2014.02.009 · doi:10.1016/j.snb.2014.02.009
- Wang, 2010, Potentiometric sensors based on surface molecular imprinting: detection of cancer biomarkers and viruses, Sens. Actuators B, 146, 381, 10.1016/j.snb.2010.02.032 · DOI · Paper page
- Chua, 2009, Label-free electrical detection of cardiac biomarker with complementary metal-oxide semiconductor-compatible silicon nanowire sensor arrays, Anal. Chem., 81, 6266, 10.1021/ac901157x · DOI · Paper page
- Karimian, 2013, An ultrasensitive molecularly-imprinted human cardiac troponin sensor, Biosens. Bioelectron., 50, 492, 10.1016/j.bios.2013.07.013 · doi:10.1016/j.bios.2013.07.013
- Qureshi, 2010, Label-free capacitive biosensor for sensitive detection of multiple biomarkers using gold interdigitated capacitor arrays, Biosens. Bioelectron., 25, 2318, 10.1016/j.bios.2010.03.018 · doi:10.1016/j.bios.2010.03.018
- Gupta, 2014, Label-free detection of C-reactive protein using a carbon nanofiber based biosensor, Biosens. Bioelectron., 59, 112, 10.1016/j.bios.2014.03.027 · DOI
- Bourigua, 2010, Impedimetric immunosensor based on SWCNT-COOH modified gold microelectrodes for label-free detection of deep venous thrombosis biomarker, Biosens. Bioelectron., 26, 1278, 10.1016/j.bios.2010.07.004 · doi:10.1016/j.bios.2010.07.004
- Ahammad, 2011, Electrochemical detection of cardiac biomarker troponin I at gold nanoparticle-modified ITO electrode by using open circuit potential, Int. J. Electrochem. Sci., 6, 1906, 10.1016/S1452-3981(23)18155-7 · doi:10.1016/s1452-3981(23)18155-7
- Chaocharoen, 2015, Electrochemical detection of the disease marker human chitinase-3-like protein 1 by matching antibody-modified gold electrodes as label-free immunosensors, Bioelectrochemistry, 101, 106, 10.1016/j.bioelechem.2014.07.006 · doi:10.1016/j.bioelechem.2014.07.006
- Luo, 2011, Ultrasensitive protein detection using an aptamer-functionalized single polyaniline nanowire, Chem. Commun., 47, 6368, 10.1039/c1cc11353d · DOI
- Luo, 2013, Ultrasensitive label free electrical detection of insulin in neat blood serum, Anal. Chem., 85, 4129, 10.1021/ac4002657 · DOI · Paper page
- Yang, 2013, An electrochemical impedance sensor for the label-free ultrasensitive detection of interleukin-6 antigen, Sens. Actuators B, 178, 310, 10.1016/j.snb.2012.12.107 · DOI
- Taleat, 2014, Electrochemical immunoassay based on aptamer–protein interaction and functionalized polymer for cancer biomarker detection, J. Electroanal. Chem., 717–718, 119, 10.1016/j.jelechem.2014.01.015 · doi:10.1016/j.jelechem.2014.01.015
- Elshafey, 2013, Label-free impedimetric immunosensor for ultrasensitive detection of cancer marker Murine double minute 2 in brain tissue, Biosens. Bioelectron., 39, 220, 10.1016/j.bios.2012.07.049 · DOI
- Rajesh, 2010, Electrochemical impedance immunosensor for the detection of cardiac biomarker Myogobin (Mb) in aqueous solution, Thin Solid. Films, 519, 1167, 10.1016/j.tsf.2010.08.063 · doi:10.1016/j.tsf.2010.08.063
- Lee, 2011, Highly sensitive single polyaniline nanowire biosensor for the detection of immunoglobulin G and myoglobin, Biosens. Bioelectron., 26, 3297, 10.1016/j.bios.2011.01.001 · doi:10.1016/j.bios.2011.01.001
- Moreira, 2011, Myoglobin-biomimetic electroactive materials made by surface molecular imprinting on silica beads and their use as ionophores in polymeric membranes for potentiometric transduction, Biosens. Bioelectron., 26, 4760, 10.1016/j.bios.2011.05.045 · doi:10.1016/j.bios.2011.05.045
- Barton, 2008, Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol, Anal. Chem., 80, 6198, 10.1021/ac800491m · DOI
- Okuno, 2007, Label-free immunosensor for prostate-specific antigen based on single-walled carbon nanotube array-modified microelectrodes, Biosens. Bioelectron., 22, 2377, 10.1016/j.bios.2006.09.038 · DOI · Paper page
- Ahmed, 2013, Novel impedimetric immunosensor for detection of pathogenic bacteria streptococcus pyogenes in human saliva, Anal. Chem., 85, 12118, 10.1021/ac403253j · DOI · Paper page
- Yan, 2011, Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine, Sens. Actuators B, 160, 1380, 10.1016/j.snb.2011.09.081 · DOI
- May, 2005, Vascular endothelial growth factor as a biomarker for the early detection of cancer using a whole cell-based biosensor, Anal. Bioanal.Chem., 382, 1010, 10.1007/s00216-005-3224-2 · DOI
- Sun, 2019, Point-of-care smartphone-based electrochemical biosensing, Electroanalysis, 31, 2, 10.1002/elan.201800474 · DOI · Paper page
- Broeders, 2013, Mobile Application for impedance-based biomimetic sensor readout, IEEE Sensors J., 13, 2659, 10.1109/JSEN.2013.2256346 · doi:10.1109/jsen.2013.2256346
- Zhang, 2016, Protein detecting with smartphone-controlled electrochemical impedance spectroscopy for point-of-care applications, Sens. Actuators B, 222, 994, 10.1016/j.snb.2015.09.041 · DOI
- Chandra, 2020, Miniaturized label-free smartphone assisted electrochemical sensing approach for personalized COVID-19 diagnosis, Sens. Int., 1
- da Silva, 2017, Electrochemical biosensors in point-of-care devices: recent advances and future trends, ChemElectroChem, 4, 778, 10.1002/celc.201600758 · DOI · Paper page
- Yılmaz, 2018, Chapter 8 - lab-on-a-chip technology and its applications, 145
- Ahmed, 2016, Paper-based chemical and biological sensors: engineering aspects, Biosens. Bioelectron., 77, 249, 10.1016/j.bios.2015.09.038 · DOI · Paper page
- Taleat, 2014, Screen-printed electrodes for biosensing: a review (2008–2013), Microchim. Acta, 181, 865, 10.1007/s00604-014-1181-1 · DOI · Paper page
- Li, 2018, Multiplex electrochemical aptasensor for detecting multiple antibiotics residues based on carbon fiber and mesoporous carbon-gold nanoparticles, Sens. Actuators B, 265, 217, 10.1016/j.snb.2018.03.042 · doi:10.1016/j.snb.2018.03.042
- Schackart, 2021, Machine learning enhances the performance of bioreceptor-free biosensors, Sensors, 21, 5519, 10.3390/s21165519 · DOI
- Paulovich, 2011, Information visualization techniques for sensing and biosensing, Analyst, 136, 1344, 10.1039/c0an00822b · DOI
- Bhalla, 2016, Introduction to biosensors, Essays Biochem., 60, 1
Metadata
- Authors
- Lopes, L. C., Santos, A., & Bueno, P. R.
- Venue
- Sensors and Actuators Reports
- Publisher
- Elsevier BV
- Published
- 2022-11
- Volume
- 4
- Pages
- 100087
- ISSN
- 2666-0539
- Cited by
- 91
- References
- 10
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Funders
- Fundação de Amparo à Pesquisa do Estado de São Paulo (2017\u2013248390, 2018/23577\u20135, 248390)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (88887.463447/2019, 88887.463447/2019\u201300)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An outlook on electrochemical approaches for molecular diagnostics assays and discussions on the limitations of miniaturized technologies for point-of-care devices. https://app.cochat.ai/papers/10.1016/j.snr.2022.100087
- The paper
- Lopes, L. C., Santos, A., & Bueno, P. R. (2022). An outlook on electrochemical approaches for molecular diagnostics assays and discussions on the limitations of miniaturized technologies for point-of-care devices. Sensors and Actuators Reports. https://doi.org/10.1016/j.snr.2022.100087
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.