The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
PANI nanofibers-supported Nb2CTx nanosheets-enabled selective NH3 detection driven by TENG at room temperature
Abstract
As a new member of the MXene family, two dimensional (2D) niobium carbide MXene (Nb2CTx) holds a promising potential in gas detection due to the abundant surface terminated groups and large specific surface area. In this work, a selective NH3 sensor based on polyaniline (PANI) nanofibers-supported Nb2CTx nanosheets (Nb2CTx/PANI) directly driven by a facile triboelectric nanogenerator (TENG) is proposed to provide a possible method for enhancing the NH3-sensing response. In addition, the gas sensing properties have been optimized by regulating different spray volumes of Nb2CTx nanosheets. Test results demonstrate that the NH3-sensing response and the response speed of the Nb2CTx/PANI-2 sensor have been evidently improved, indicating a good linear response toward a wide sensing range of 1–100 ppm NH3 at room temperature (∼25℃) under 87.1 % relative humidity (RH). Moreover, the influence of high humidity on gas sensing response of the Nb2CTx/PANI-2 sensor has been efficiently reduced due to the occupied active sites for water adsorption caused by intermolecular hydrogen bonds between PANI and Nb2CTx. Finally, mechanism of the enhanced gas sensing properties has been further investigated, which should be mainly attributed to the gas sensing improvement effect of p-n junction. This work is expected to offer a useful reference for the development of high-performance Nb2CTx/polymer-based gas sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metallic Ti3C2T x MXene Gas Sensors with Ultrahigh Signal-to-Noise Ratio
Kim, S. J., Koh, H.-J., Ren, C. E., Kwon, O., Maleski, K., Cho, S.-Y., Anasori, B., Kim, C.-K., Choi, Y.-K., Kim, J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07460 · Cited by 1,699
Room Temperature Gas Sensing of Two-Dimensional Titanium Carbide (MXene)
Lee, E., VahidMohammadi, A., Prorok, B. C., Yoon, Y. S., Beidaghi, M., & Kim, D.-J. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b11055 · Cited by 878
Evolution of breath analysis based on humidity and gas sensors: Potential and challenges
Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128104 · Cited by 412
Self-citation
Cited by
Zhang, D., Yu, S., Wang, X., Huang, J., Pan, W., Zhang, J., Meteku, B. E., & Zeng, J. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.127160 · Cited by 424
Chaudhary, V., Kaushik, A., Furukawa, H., & Khosla, A. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac5ac6 · Cited by 386
Triboelectric Nanogenerator‐Based Sensor Systems for Chemical or Biological Detection
Zhou, Q., Pan, J., Deng, S., Xia, F., & Kim, T. (2021) · Advanced Materials · doi:10.1002/adma.202008276 · Cited by 259
Metadata
- Authors
- Wang, S., Liu, B., Duan, Z., Zhao, Q., Zhang, Y., Xie, G., Jiang, Y., Li, S., & Tai, H.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 327
- Pages
- 128923
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3087154236
- Cited by
- 196
- References
- 3
- FWCI
- 7.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.