Paper-based microfluidics: Simplified fabrication and assay methods
Open accessThe DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Abstract
Paper-based microfluidics is the branch of microfluidics involving devices made out of paper, or other porous membranes, that wick fluids by capillary action. Paper-based microfluidic devices have several advantages over conventional microfluidic devices including simpler fabrication, lower cost, easier disposal, and the ability to operate without pumps or other supporting equipment. The most common application of paper-based microfluidic devices is in the development of point-of-care (POC) diagnostic devices, which could eliminate the need for costly and time-consuming laboratory-based analytical procedures. This review provides an overview of current methods of fabricating paper-based microfluidic devices, examples of applications of these devices, a discussion of their current limitations, and an outlook on their future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Dynamics of Capillary Flow
Washburn, E. W. (1921) · Physical Review · doi:10.1103/physrev.17.273 · Cited by 7,141
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
Self-citationCRISPR–Cas12-based detection of SARS-CoV-2
Broughton, J. P., Deng, X., Yu, G., Fasching, C. L., Servellita, V., Singh, J., Miao, X., Streithorst, J. A., Granados, A., Sotomayor-Gonzalez, A., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0513-4 · Cited by 2,717
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Self-citationThe innovator's solution: creating and sustaining successful growth
(2014) · Choice Reviews Online · doi:10.5860/choice.51-5108 · Cited by 2,002
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Li, Z., Yi, Y., Luo, X., Xiong, N., Liu, Y., Li, S., Sun, R., Wang, Y., Hu, B., Chen, W., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25727 · Cited by 1,771
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Self-citationMartinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,443
Self-citation
Cited by
Saravanan, P., Saravanan, V., Rajeshkannan, R., Arnica, G., Rajasimman, M., Baskar, G., & Pugazhendhi, A. (2024) · Environmental Research · doi:10.1016/j.envres.2024.119440 · Cited by 377
RetractedMicrofluidic Devices: A Tool for Nanoparticle Synthesis and Performance Evaluation
Gimondi, S., Ferreira, H., Reis, R. L., & Neves, N. M. (2023) · ACS Nano · doi:10.1021/acsnano.3c01117 · Cited by 376
Metadata
- Authors
- Nishat, S., Jafry, A. T., Martinez, A. W., & Awan, F. R.
- Venue
- Sensors and Actuators B: Chemical
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 336
- Pages
- 129681
- ISSN
- 0925-4005 (ISSN-L)
- OpenAlex
- W3132554978
- Cited by
- 392
- References
- 101
- FWCI
- 18.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.