The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Comparison of the energy saving potential of adaptive and controllable smart windows: A state-of-the-art review and simulation studies of thermochromic, photochromic and electrochromic technologies
Open accessAbstract
Abstract Windows play a huge role in today's buildings, allowing for outside view and providing occupants with daylight. However, windows are also often considered to be one of the weakest building components with respect to high thermal losses and are in addition often the reason for overheating and glare issues. In comparison to traditional static windows, dynamic solutions like adaptive and controllable smart windows have the ability to adjust their optical properties in response to changing boundary conditions and hence have the potential to improve the energy performance and the user comfort of buildings. The objective of this work is twofold: (1) To collect and present the state-of-the-art of commercially available smart windows from manufacturers, both adaptive and controllable products, i.e. thermochromic, photochromic and electrochromic smart windows. This collection provides the reader with valuable information about window properties such as the U-value, g-value, solar transmittance (Tsol) and visible solar transmittance (Tvis). However, it is currently difficult to obtain all the desired information about the products from the manufacturers' websites and other open channels. (2) To conduct building energy performance simulations on selected products from each technology. These products are also simulated using the same U-values as the reference window, and in addition, two theoretical cases have been simulated to investigate the theoretical potential of different smart windows. Here, the optical parameters take on fictitious values between 10 and 90% and between 0 and 100% transmittance, respectively. All cases are simulated at three different locations, i.e. Trondheim (Norway), Madrid (Spain) and Nairobi (Kenya), and are compared to a reference static window. In total, 63 cases are simulated using the simulation software package IDA Indoor Climate and Energy (IDA ICE). The results shows that the electrochromic window controlled by operative temperature has the highest potential in lowering the energy demand for all cases and locations. The study also highlights the importance of having the right control strategy and control levels for each specific case.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Baetens, R., Jelle, B. P., & Gustavsen, A. (2009) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2009.08.021 · Cited by 1,322
Self-citationElectrochromic organic and polymeric materials for display applications
Mortimer, R. J., Dyer, A. L., & Reynolds, J. R. (2006) · Displays · doi:10.1016/j.displa.2005.03.003 · Cited by 1,100
Climate adaptive building shells: State-of-the-art and future challenges
Loonen, R. C. G. M., Trčka, M., Cóstola, D., & Hensen, J. L. M. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.016 · Cited by 637
Self-citationElectrochromic materials and devices for energy efficient windows
Lampert, C. M. (1984) · Solar Energy Materials · doi:10.1016/0165-1633(84)90024-8 · Cited by 575
Fenestration of today and tomorrow: A state-of-the-art review and future research opportunities
Jelle, B. P., Hynd, A., Gustavsen, A., Arasteh, D., Goudey, H., & Hart, R. (2012) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2011.08.010 · Cited by 551
Self-citationOxide electrochromics: An introduction to devices and materials
Granqvist, C. G. (2012) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2011.08.021 · Cited by 440
Active dynamic windows for buildings: A review
Casini, M. (2018) · Renewable Energy · doi:10.1016/j.renene.2017.12.049 · Cited by 406
Monitoring manual control of electric lighting and blinds
Reinhart, C., & Voss, K. (2003) · Lighting Research & Technology · doi:10.1191/1365782803li064oa · Cited by 344
Smart switchable glazing for solar energy and daylight control
Lampert, C. M. (1998) · Solar Energy Materials and Solar Cells · doi:10.1016/s0927-0248(97)00279-1 · Cited by 307
Loonen, R. C. G. M., Favoino, F., Hensen, J. L. M., & Overend, M. (2017) · Journal of Building Performance Simulation · doi:10.1080/19401493.2016.1152303 · Cited by 259
Self-citationAdvances in chromogenic materials and devices
Granqvist, C., Green, S. V., Niklasson, G. A., Mlyuka, N. R., von Kraemer, S., & Georén, P. (2009) · Thin Solid Films · doi:10.1016/j.tsf.2009.08.058 · Cited by 223
Current trends and future challenges in the performance assessment of adaptive façade systems
Attia, S., Bilir, S., Safy, T., Struck, C., Loonen, R., & Goia, F. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.09.017 · Cited by 211
Self-citationElectrochromic materials and devices
Mortimer, R. J., Rosseinsky, D. R., & Monk, P. (2015) · Cited by 195
Jelle, B. P. (2013) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2013.04.032 · Cited by 193
Self-citationDeForest, N., Shehabi, A., O'Donnell, J., Garcia, G., Greenblatt, J., Lee, E. S., Selkowitz, S., & Milliron, D. J. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.021 · Cited by 172
DeForest, N., Shehabi, A., Selkowitz, S. E., & Milliron, D. J. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.02.007 · Cited by 166
Hoffmann, S., Lee, E. S., & Clavero, C. (2014) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2013.12.017 · Cited by 143
Dussault, J.-M., & Gosselin, L. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.07.046 · Cited by 130
Jelle, B. P., & Hagen, G. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2221126 · Cited by 127
Self-citationHoffmann, S., Lee, E. S., McNeil, A., et al. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.12.009 · Cited by 88
Piccolo, A., Marino, C., Nucara, A., & Pietrafesa, M. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.12.049 · Cited by 81
Lee, E. S., Pang, X., Hoffmann, S., Goudey, H., & Thanachareonkit, A. (2013) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2013.03.043 · Cited by 77
Jelle, B. P., Gustavsen, A., Nilsen, T.-N., & Jacobsen, T. (2006) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2006.10.017 · Cited by 70
Self-citationControl algorithms for dynamic windows for residential buildings
Firląg, S., Yazdanian, M., Curcija, C. D., Köhler, C., Vidanovic, S., Hart, R., & Czarnecki, S. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.09.069 · Cited by 61
Jelle, B. P., Hagen, G., & Birketveit, Ø. (1998) · Journal of Applied Electrochemistry · doi:10.1023/a:1003213110819 · Cited by 39
Self-citationReduction factor for polyaniline films on ito from cyclic voltammetry and visible absorption spectra
Jelle, B. P., Hagen, G., Hesjevik, S. M., & Ødegård, R. (1993) · Electrochimica Acta · doi:10.1016/0013-4686(93)85054-3 · Cited by 34
Self-citationWang, T., Ward, G. J., & Lee, E. S. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.06.022 · Cited by 31
Cited by
Alkhatib, H., Lemarchand, P., Norton, B., & O'Sullivan, D. T. J. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116331 · Cited by 126
Metadata
- Authors
- Tällberg, R., Jelle, B. P., Loonen, R., Gao, T., & Hamdy, M.
- Venue
- Solar Energy Materials and Solar Cells
- Publisher
- Elsevier BV
- Published
- 2019-09
- Volume
- 200
- Pages
- 109828
- ISSN
- 0927-0248 (ISSN-L)
- OpenAlex
- W2896337664
- Cited by
- 310
- References
- 27
- FWCI
- 23.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.