The DOI matches its Crossref record.
Monitoring manual control of electric lighting and blinds
Open accessAbstract
This paper reviews, validates and extends present knowledge of the degree and kind of manual control strategies of blinds and electric lighting systems that are used in private and two-person offices. A new monitoring setup was applied from March to December 2000 in 10 daylit offices in Germany that featured manually operated electric lighting and automatically controlled external venetian blinds with manual override. The data shows that individuals consistently followed the same control strategy for their electric lighting and blinds. Groups of individuals tended to activate their electric lighting according to Hunt’s probability function, although there was a large spread between individual control levels. All subjects used their blinds to avoid direct sunlight above 50 W/m 2, and incoming solar gains above 50 klux (~450 W/m 2). They also were more willing to accept automatic blind opening than closing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Occupant behavior modeling for building performance simulation: Current state and future challenges
Yan, D., O’Brien, W., Hong, T., Feng, X., Burak Gunay, H., Tahmasebi, F., & Mahdavi, A. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.08.032 · Cited by 894
Galasiu, A. D., & Veitch, J. A. (2006) · Energy and Buildings · doi:10.1016/j.enbuild.2006.03.001 · Cited by 631
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
Yan, D., Hong, T., Dong, B., Mahdavi, A., D’Oca, S., Gaetani, I., & Feng, X. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.09.084 · Cited by 508
Dubois, M.-C., & Blomsterberg, Å. (2011) · Energy and Buildings · doi:10.1016/j.enbuild.2011.07.001 · Cited by 361
Valitabar, M., GhaffarianHoseini, A., GhaffarianHoseini, A., & Attia, S. (2022) · Architectural Engineering and Design Management · doi:10.1080/17452007.2022.2032576 · Cited by 35
Metadata
- Authors
- Reinhart, C., & Voss, K.
- Venue
- Lighting Research & Technology
- Publisher
- SAGE Publications
- Published
- 2003-09
- Volume
- 35
- Issue
- 3
- Pages
- 243-258
- ISSN
- 0024-3426 (ISSN-L)
- 1477-1535
- 1477-0938
- OpenAlex
- W2031327648
- Cited by
- 344
- References
- 0
- FWCI
- 19.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring manual control of electric lighting and blinds. https://app.cochat.ai/papers/10.1191/1365782803li064oa
- The paper
- Reinhart, C., & Voss, K. (2003). Monitoring manual control of electric lighting and blinds. Lighting Research & Technology. https://doi.org/10.1191/1365782803li064oa
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.