Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 185 of the 187 references it cites were found in a registry or an index; none of the 130 sources its claims cite is checked for support yet.

Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies

Open access
Kocman, Vojč, Di Mauro, Giacomo M., Veglia, Gianluigi, Ramamoorthy, Ayyalusamy · 2019 · Solid State Nuclear Magnetic Resonance

Abstract

NMR spectroscopy is a powerful experimental technique to study biological systems at the atomic resolution. However, its intrinsic low sensitivity results in long acquisition times that in extreme cases lasts for days (or even weeks) often exceeding the lifetime of the sample under investigation. Different paramagnetic agents have been used in an effort to decrease the spin-lattice (T1) relaxation times of the studied nuclei, which are the main cause for long acquisition times necessary for signal averaging to enhance the signal-to-noise ratio of NMR spectra. Consequently, most of the experimental time is “wasted” in waiting for the magnetization to recover between successive scans. In this review, we discuss how to set up an optimal paramagnetic relaxation enhancement (PRE) system to effectively reduce the T1 relaxation times avoiding significant broadening of NMR signals. Additionally, we describe how PRE-agents can be used to provide structural and dynamic information and can even be used to follow the intermediates of chemical reactions and to speed-up data acquisition. We also describe the unique challenges and benefits associated with the application of PRE to solid-state NMR spectroscopy, explaining how the use of PREs is more complex for membrane mimetic systems as PREs can also be exploited to change the alignment of oriented membrane systems. Functionalization of membrane mimetics, such as bicelles, can provide a controlled region of paramagnetic effect that has the potential, together with the desired alignment, to provide crucial biologically relevant structural information. And finally, we discuss how paramagnetic metals can be utilized to further increase the dynamic nuclear polarization (DNP) effects and how to preserve the enhancements when dissolution DNP is implemented.

Overview

CoChat Summary

TL;DR

This review describes how paramagnetic relaxation enhancement (PRE) agents can shorten T1 relaxation times to accelerate NMR data acquisition while minimizing T2 broadening, and how the same paramagnetic systems provide structural and dynamic information in solution and solid-state NMR. It also covers applications to membrane mimetics, magnetically aligned systems, and dynamic nuclear polarization (DNP).

Key findings

  • Paramagnetic probes—nitroxide radicals, linear and macrocyclic metal chelators, and paramagnetic metal ions—can reduce T1 and shorten recycle delays; optimal systems minimize T2 broadening. For example, Ni(DO2A) significantly decreased proton T1 with negligible line broadening, whereas Ni(EDTA)2− caused severe line broadening with no observable 1H-15N HSQC signals.
  • PRE effects depend on distance with an r−6 dependence, and metal ions can affect nuclei up to 35 Å; the region closest to the paramagnetic center is a “blind zone.” Solvent PRE and tagged lipids can identify solvent-exposed versus transmembrane residues and report on membrane orientation.
  • In solid-state NMR, paramagnetic doping shortened 1H T1 and enabled CP-MAS natural-abundance 13C measurements on bone; Cu2+ quenching indicated glycine, proline, and alanine near the bone mineral surface. In X-Cu(II)-HY zeolite, T1 measurements identified Cu2+ binding sites and the reaction pathway of acetone conversion.
  • DNP applications: stable radicals can increase polarization by as much as 10,000 times and more at ~1–2 K; trace paramagnetic additives enhanced solid-state 13C DNP signals by 100–250%; Mn2+ and Gd3+ dopants polarized 7Li in LTO particles with enhancement factors of 3 to 14.

Methods

  • Design: review article; it does not report new primary experimental data.
  • Data or sample: published literature on paramagnetic relaxation enhancement, paramagnetic tags and chelators, membrane mimetics (bicelles, nanodiscs, liposomes), solid-state NMR, and DNP.
  • Main analysis: thematic synthesis of reported approaches for selecting and positioning paramagnetic systems to reduce T1, obtain structural/dynamic information, and enhance DNP.

Limitations

  • The paper states that using paramagnetism in solid-state NMR is challenging for membrane mimetics and magnetically aligned samples because paramagnetic agents can also magnetically align and alter the alignment direction of membrane-mimicking systems; RF-induced heating can denature isotope-labeled membrane proteins or damage probes.
  • The paper states that, to the authors’ knowledge, there is no report in the literature about PRE studies using aligned macro-nanodiscs; proposed approaches remain untested.
  • Evident from the text: as a review, it provides no new experimental validation and relies on cited studies; it also notes that high salt can have undesired effects on protein–lipid interactions, and that the paramagnetic center must be chosen to reduce T1 without significantly affecting T2.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1016/j.ssnmr.2019.07.002

Cites

185 of 185 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 0 Not valid · 59 Not checked · 32 Own results and interpretations

52 more claims

Create a free account to see all 91 claims and to verify the 128 references still open.

See all claims — free account
  • Probably not a substantial claim. 10
  • It may state two separate claims as one. 26

Create a free account to see these claims.

Citations

Cites

Show all 187 references

Research works printed but not linked: 3

  1. Ravula, 2019, Magnetic-alignment of polymer macro-nanodiscs enable residual dipo- lar couplings based high-resolution structural studies by NMR, BioRxiv, 1
  2. Lilly Thankamony, 2017, Dynamic nuclear polarization for sensitivity enhancement in modern solid-state NMR, Prog. Nucl. Magn. Reson. Spectrosc., 102–103, 120, 10.1016/j.pnmrs.2017.06.002 · DOI · Paper page
  3. Niedbalski, 2017, 13C dynamic nuclear polarization using a trimeric Gd3+ complex as an additive, J. Phys. Chem. A, 121, 5127, 10.1021/acs.jpca.7b03869 · DOI · Paper page

Cited by

See all 45

Metadata

Authors
Kocman, V., Di Mauro, G. M., Veglia, G., & Ramamoorthy, A.
Affiliations
  • University of Michigan (US)
  • University of Minnesota (US)
Corresponding author
Ramamoorthy, Ayyalusamy
Venue
Solid State Nuclear Magnetic Resonance
Publisher
Elsevier BV
Published
2019-10
Volume
102
Pages
36-46
ISSN
0926-2040 (ISSN-L)
OpenAlex
W2958017326
Cited by
45
References
187
Citations by year
2026: 4 · 2025: 10 · 2024: 7 · 2023: 4 · 2022: 7 · 2021: 3 · 2020: 6 · 2019: 4
FWCI
0.42
Type
journal article
Language
en
Open access
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Locations
  • Solid State Nuclear Magnetic Resonance (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institutes of Health (GM084018, GM64742)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
  • Physical Sciences › Materials Science › Materials Chemistry › Lanthanide and Transition Metal Complexes
Keywords
paramagnetic relaxation enhancement, spin-lattice relaxation, signal-to-noise ratio, solid-state NMR, membrane mimetics, bicelles, dynamic nuclear polarization, dissolution dynamic nuclear polarization, paramagnetic metals, reaction intermediates
MeSH terms
Data Analysis, Cell Membrane, Micelles, Magnetic Resonance Spectroscopy, Time Factors, Magnetic Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-18, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-18 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies. https://app.cochat.ai/papers/10.1016/j.ssnmr.2019.07.002
The paper
Kocman, V., Di Mauro, G. M., Veglia, G., & Ramamoorthy, A. (2019). Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies. Solid State Nuclear Magnetic Resonance. https://doi.org/10.1016/j.ssnmr.2019.07.002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.