Bilayer-Mediated Structural Transitions Control Mechanosensitivity of the TREK-2 K2P Channel
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
channels (TREK-1, TREK-2, and TRAAK) are important for mechanical and thermal nociception. However, the mechanisms underlying their gating by membrane stretch remain controversial. Here we use molecular dynamics simulations to examine their behavior in a lipid bilayer. We show that TREK-2 moves from the "down" to "up" conformation in direct response to membrane stretch, and examine the role of the transmembrane pressure profile in this process. Furthermore, we show how state-dependent interactions with lipids affect the movement of TREK-2, and how stretch influences both the inner pore and selectivity filter. Finally, we present functional studies that demonstrate why direct pore block by lipid tails does not represent the principal mechanism of mechanogating. Overall, this study provides a dynamic structural insight into K2P channel mechanosensitivity and illustrates how the structure of a eukaryotic mechanosensitive ion channel responds to changes in forces within the bilayer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
‘Improved parameters for the Martini coarse-grained protein force field’
de Jong, D. H., Singh, G., Bennett, W. F. D., Arnarez, C., Wassenaar, T. A., Schäfer, L. V., Periole, X., Tieleman, D. P., & Marrink, S. J. (2013) · Journal of Chemical Theory and Computation · doi:10.1021/ct300646g · Cited by 1,486
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
Cited by
Discoveries in structure and physiology of mechanically activated ion channels
Kefauver, J. M., Ward, A. B., & Patapoutian, A. (2020) · Nature · doi:10.1038/s41586-020-2933-1 · Cited by 604
Muller, M. P., Jiang, T., Sun, C., Lihan, M., Pant, S., Mahinthichaichan, P., Trifan, A., & Tajkhorshid, E. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00608 · Cited by 282
Mechanosensitive Ion Channels: Structural Features Relevant to Mechanotransduction Mechanisms
Jin, P., Jan, L. Y., & Jan, Y.-N. (2020) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-070918-050509 · Cited by 274
Mammalian Mechanoelectrical Transduction: Structure and Function of Force-Gated Ion Channels
Douguet, D., & Honoré, E. (2019) · Cell · doi:10.1016/j.cell.2019.08.049 · Cited by 217
Duncan, A. L., Song, W., & Sansom, M. S. P. (2020) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010919-023411 · Cited by 158
Self-citation
Metadata
- Authors
- Aryal, P., Jarerattanachat, V., Clausen, M. V., Schewe, M., McClenaghan, C., Argent, L., Conrad, L. J., Dong, Y. Y., Pike, A. C. W., Carpenter, E. P., Baukrowitz, T., Sansom, M. S. P., & Tucker, S. J.
- Venue
- Structure
- Publisher
- Elsevier BV
- Published
- 2017-05
- Volume
- 25
- Issue
- 5
- Pages
- 708-718.e2
- ISSN
- 0969-2126 (ISSN-L)
- OpenAlex
- W2604628994
- Cited by
- 82
- References
- 2
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bilayer-Mediated Structural Transitions Control Mechanosensitivity of the TREK-2 K2P Channel. https://app.cochat.ai/papers/10.1016/j.str.2017.03.006
- The paper
- Aryal, P., Jarerattanachat, V., Clausen, M. V., Schewe, M., McClenaghan, C., Argent, L., Conrad, L. J., Dong, Y. Y., Pike, A. C. W., Carpenter, E. P., Baukrowitz, T., Sansom, M. S. P., & Tucker, S. J. (2017). Bilayer-Mediated Structural Transitions Control Mechanosensitivity of the TREK-2 K2P Channel. Structure. https://doi.org/10.1016/j.str.2017.03.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.