The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Determination of copper and nickel in vegetable oils by direct sampling graphite furnace atomic absorption spectrometry
Abstract
The quality of food products has been receiving great attention due to its influence on human nutrition and health. In this sense, the determination of trace metals in foods has turned an important field on food analysis. Concerning vegetable oils, its metal trace composition is an important criterion for the assessment of their quality once it is known that trace metals affect their rate of oxidation, influencing freshness, keeping properties as well as storage. In the present work an analytical method which enables the direct determination of Cu and Ni in vegetable oils by graphite furnace atomic absorption spectrometry (GFAAS), using a "solid" sample strategy is presented: in nature, samples are directly weighed on the graphite platform boat and inserted in the graphite tube. An adequate temperature program permitted the calibration by external aqueous analytical curves. Good concordance between the proposed procedure and EPA procedures was found in the analysis of real samples. Limits of detection of 0.001 and 0.002mugg(-1) were found for Cu and Ni, respectively, in the original samples, and they were comfortably below the concentrations found.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Direct determination of trace metals in oils by atomic spectroscopic techniques is difficult due to high viscosity and high organic contents of oils.
“However, direct determination of trace metals in oils by AS is dif fi cult due to high viscosity and high organic contents of oils [13,14].”
Citations
Cites
Ashing techniques in the determination of iron and copper in palm oil
Saleh, M. I., Murray, R. S., & Chin, C. N. (1988) · Journal of the American Oil Chemists' Society · doi:10.1007/bf02542378 · Cited by 20
Flagged first, then by citations
Cited by
Sorted by citations
Karimi, M., Dadfarnia, S., Shabani, A. M. H., Tamaddon, F., & Azadi, D. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.021 · Cited by 182
López-García, I., Vicente-Martínez, Y., & Hernández-Córdoba, M. (2014) · Talanta · doi:10.1016/j.talanta.2014.02.011 · Cited by 87
Metadata
- Authors
- Matos Reyes, M. N., & Campos, R. C.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2006-12-15
- Volume
- 70
- Issue
- 5
- Pages
- 929-932
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2037703160
- Cited by
- 79
- References
- 1
- Citations by year
- 2023: 3 · 2022: 5 · 2021: 3 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 3 · 2015: 11 · 2014: 6 · 2013: 1 · 2012: 11
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Organic Chemistry › Edible Oils Quality and Analysis
- Physical Sciences › Chemistry › Spectroscopy › Laser-induced spectroscopy and plasma
- Keywords
- copper determination, nickel determination, vegetable oils, direct sampling, trace metals in food, food quality, oil oxidation, detection limit
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review