The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ratiometric and turn-on monitoring for heavy and transition metal ions in aqueous solution with a fluorescent peptide sensor
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hazards of heavy metal contamination
Järup, L. (2003) · British Medical Bulletin · doi:10.1093/bmb/ldg032 · Cited by 6,508
Cited by
Colorimetric Detection of Mercury Ions Based on Plasmonic Nanoparticles
Du, J., Jiang, L., Shao, Q., Liu, X., Marks, R. S., Ma, J., & Chen, X. (2013) · Small · doi:10.1002/smll.201200811 · Cited by 289
Liu, Q., Wang, J., & Boyd, B. J. (2015) · Talanta · doi:10.1016/j.talanta.2014.12.020 · Cited by 277
Metadata
- Authors
- Joshi, B. P., Park, J., Lee, W. I., & Lee, K. H.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2009-05-15
- Volume
- 78
- Issue
- 3
- Pages
- 903-909
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W1986140374
- Cited by
- 202
- References
- 1
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ratiometric and turn-on monitoring for heavy and transition metal ions in aqueous solution with a fluorescent peptide sensor. https://app.cochat.ai/papers/10.1016/j.talanta.2008.12.062
- The paper
- Joshi, B. P., Park, J., Lee, W. I., & Lee, K. H. (2009). Ratiometric and turn-on monitoring for heavy and transition metal ions in aqueous solution with a fluorescent peptide sensor. Talanta. https://doi.org/10.1016/j.talanta.2008.12.062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.