The DOI matches its Crossref record.
Separation/preconcentration and determination of cadmium ions by solidification of floating organic drop microextraction and FI-AAS
Abstract
A simple and selective method for the separation and preconcentration of cadmium in water samples based on solidified floating organic drop microextraction (SFODME) was developed. The cadmium ion in aqueous solution was converted to CdI(4)(2-) and was then extracted with 160 microL of 1-undecanol containing cationic surfactant of methyltrioctylammonium chloride (0.2 mol/L). When the extraction was completed, the sample vial was cooled in an ice bath for 5 min. The solidified extract was transferred into a conical vial where it melted immediately. It was then diluted to 250 microL upon addition of ethanol, and 100 microL of it was analyzed by flow injection flame atomic absorption spectrometry (FI-FAAS). Factors that influence the extraction and ion pair formation, such as pH, concentration of iodide and methyltrioctylammonium chloride, extraction time, sample volume, and ionic strength were optimized. Under the optimized conditions, a preconcentration factor of 640, detection limit of 0.0079 microg/L and good relative standard deviation of +/-5.4% at 5 microg/L were obtained. The procedure was applied to tap water, well water, and sea water; and accuracy was assessed through recovery experiment and independent analysis by graphite atomic absorption spectrometry. The accuracy was also evaluated through analyses of certified reference ore.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dadfarnia et al. [36] proposed a LPME-SFO method for preconcentration and extraction of cadmium ions in different water samples (tap water, well water, and sea water).
“Dadfarnia et al. [36] proposed a LPME-SFO method for preconcentration and extraction of cadmium ions in different water samples (tap water, well water, and sea water).”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [36]
For the LPME-SFO-FI-FAAS determination of cadmium ions in water samples, the LOD was 0.0079 μg L-1.
“The LOD was 0.0079 μ g L -1”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [36]
For the LPME-SFO-FI-FAAS determination of cadmium ions in water samples, the RSD was less than 5.4% at 5 μg L-1.
“with a good RSD less than 5.4% at 5 μ g L -1 .”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [36]
Citations
Cited by
Sorted by citations
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Self-citationTrends in liquid-phase microextraction, and its application to environmental and biological samples
Han, D., & Row, K. H. (2012) · Microchimica Acta · doi:10.1007/s00604-011-0678-0 · Cited by 175
Karimi, M., Shabani, A. M. H., & Dadfarnia, S. (2016) · Microchimica Acta · doi:10.1007/s00604-015-1671-9 · Cited by 94
Self-citationRivas, R. E., López-García, I., & Hernández-Córdoba, M. (2010) · Analytical Methods · doi:10.1039/b9ay00237e · Cited by 47
Soylak, M., & Yilmaz, E. (2015) · Analytical Letters · doi:10.1080/00032719.2014.949732 · Cited by 42
Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop
WANG, Y.-Y., ZHAO, G.-Y., CHANG, Q.-Y., ZANG, X.-H., WANG, C., & WANG, Z. (2010) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(09)60073-6 · Cited by 31
Pourbakhshi, Y., Heidari, M., Yahaei, E., Ghiyasi, S., Ebrahimi-Najafabadi, H., & Bozorgzadeh, E. (2021) · Journal of Analytical Chemistry · doi:10.1134/s1061934821060083 · Cited by 10
Metadata
- Authors
- Dadfarnia, S., Haji Shabani, A. M., & Kamranzadeh, E.
- Affiliations
- Yazd University (IR)
- Corresponding author
- Dadfarnia, Shayessteh
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2009-09-15
- Volume
- 79
- Issue
- 4
- Pages
- 1061-1065
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W1970398745
- Cited by
- 97
- References
- 0
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2022: 4 · 2021: 4 · 2020: 3 · 2019: 5 · 2018: 4 · 2017: 4 · 2016: 8 · 2015: 9 · 2014: 6 · 2013: 7 · 2012: 10
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemical Engineering › Filtration and Separation › Chemical and Physical Properties in Aqueous Solutions
- Keywords
- cadmium, preconcentration, Aliquat 336, cationic surfactants, ion pairing, 1-undecanol, water samples, tap water, well water, seawater
- MeSH terms
- Absorption, Quaternary Ammonium Compounds, Cadmium, Hydrogen-Ion Concentration, Iodides, Organic Chemicals, Solvents, Spectrophotometry, Atomic, Time Factors, Water, Water Pollutants, Chemical, Flow Injection Analysis, Cadmium Compounds, Solid Phase Microextraction, Analytic Sample Preparation Methods
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review