CoChat

Dispersive Liquid–Liquid Microextraction Followed by Solidified Floating Organic Drop for Hexavalent Chromium Determination: a Method for Occupational and Environmental Exposure Monitoring for Heavy Metals

Pourbakhshi, Yasaman, Heidari, Mahmoud, Yahaei, Elham, Ghiyasi, Samira, Ebrahimi-Najafabadi, Heshmatollah, Bozorgzadeh, Elahe · 2021 · Journal of Analytical Chemistry

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Abstract Dispersive liquid−liquid microextraction solidified floating organic drop (SFOD−DLLME) technique was used for sample treatment and extraction of hexavalent chromium from spiked and real samples of workplace ambient air and urine of chromium electroplating workers. Validation of the SFOD−DLLME technique with three solvents, namely, 1-undecanol, 2-dodecanol and n-hexadecane, showed that pH 4, stirring rates of 600 rpm for 1-undecanol and 2-dodecanol and 800 rpm for n-hexadecane, extraction times of 10 min for 1-undecanol and 2-dodecanol and 15 min for n-hexadecane were the conditions allowing to reach the highest extraction efficiency. The maximum acquired enrichment factor was 211 and LODs were in the range of 0.015–0.05 µg/L, and the calibration curves were linear in the range of 0.5–30 µg/L. The results showed that SFOD−DLLME coupled with atomic absorption spectroscopy is a precise and sensitive technique for the determination of hexavalent chromium for biological monitoring of occupational/environmental samples.

Overview

Integrity signals

Registry

Crossref · 10.1134/s1061934821060083

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 29 references

Research works printed but not linked: 3

  1. Environmental Protection Agency, Toxicological review of trivalent chromium (CAS no. 16065-83-1), in Support of Summery Information on the Integrated Risk System (IRIS), Washington, DC: US Environmental Protection Agency, 1998.
  2. Agents Classified by the IARC Monographs, vol. 1–120, 2012. http://monographs.iarc.fr/ENG/Classification/ClassificationsAlphaOrder.pdf. Accessed December 20, 2017.
  3. Ahmadi, S.H., Haji Shabani, A.M., Dadfarnia, S., and Taei, M., Turk. J. Chem., 2007, vol. 31, p, 191.

Cited by

See all 10

Metadata

Authors
Pourbakhshi, Y., Heidari, M., Yahaei, E., Ghiyasi, S., Ebrahimi-Najafabadi, H., & Bozorgzadeh, E.
Affiliations
  • Guilan University of Medical Sciences (IR)
  • Islamic Azad University, Tehran (IR)
Corresponding author
Heidari, Mahmoud
Venue
Journal of Analytical Chemistry
Published
2021-06
Volume
76
Issue
6
Pages
714-720
ISSN
  • 0021-8766 (ISSN-L)
  • 1061-9348
  • 1608-3199
OpenAlex
W3167390430
Cited by
10
References
29
Citations by year
2026: 2 · 2024: 3 · 2023: 1 · 2022: 4
FWCI
1.00
Type
journal article
Language
en
Open access
closed
Licence
Locations
Journal of Analytical Chemistry (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
Keywords
hexavalent chromium, dispersive liquid-liquid microextraction, urine, occupational exposure, environmental exposure, biomonitoring, heavy metals, extraction solvent optimization, enrichment factor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dispersive Liquid–Liquid Microextraction Followed by Solidified Floating Organic Drop for Hexavalent Chromium Determination: a Method for Occupational and Environmental Exposure Monitoring for Heavy Metals. https://app.cochat.ai/papers/10.1134/s1061934821060083
The paper
Pourbakhshi, Y., Heidari, M., Yahaei, E., Ghiyasi, S., Ebrahimi-Najafabadi, H., & Bozorgzadeh, E. (2021). Dispersive Liquid–Liquid Microextraction Followed by Solidified Floating Organic Drop for Hexavalent Chromium Determination: a Method for Occupational and Environmental Exposure Monitoring for Heavy Metals. Journal of Analytical Chemistry. https://doi.org/10.1134/s1061934821060083

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.