Ultrasound-assisted emulsification–microextraction combined with flame atomic absorption spectrometry for determination of trace cadmium in water samples
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The process of ultrasound-assisted emulsification-microextraction (USAEME) was successfully applied for the first time for the extraction and pre-concentration of trace cadmium from water samples, followed by flame atomic absorption spectrometry (FAAS). In the proposed approach, sodium diethyldithiocarbamate trihydrate solution (NaDDTC.3H(2)O) was used as a chelating agent and carbon tetrachloride was selected as extraction solvent. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters included extraction solvent type as well as extraction volume, time, temperature, and pH, the amount of the chelating agent, and salt effect. Under optimum conditions, an enrichment factor of 95 was obtained from only 5.0 mL of water sample. The calibration graph was linear in the range of 10-600 microg L(-1) with a detection limit of 0.91 microg L(-1). The relative standard deviation (R.S.D) for ten replicate measurements of 50 and 500 microg L(-1) of cadmium were 2.56 and 1.62%. This proposed method was successfully applied in the analysis of four real environmental water samples and good spiked recoveries over the range of 96.5-101.7% were obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.03.005 · Cited by 258
Ozcan, S., Tor, A., & Aydin, M. E. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.06.037 · Cited by 113
Cited by
Zounr, R. A., Tuzen, M., Deligonul, N., & Khuhawar, M. Y. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.01.167 · Cited by 127
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Mandlate, J. S., Soares, B. M., Seeger, T. S., Vecchia, P. D., Mello, P. A., Flores, E. M. M., & Duarte, F. A. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2016.11.075 · Cited by 72
Metal applications of liquid-phase microextraction
Aguirre, M. Á., Baile, P., Vidal, L., & Canals, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.032 · Cited by 67
Soylak, M., & Yilmaz, E. (2015) · Analytical Letters · doi:10.1080/00032719.2014.949732 · Cited by 42
“…print=1532-236X online DOI: 10.1080/00032719.2014.949732 464 levels in samples that may be below the instrumental detection limit (Dadfarnia et al. 2009; Rojas, Ojeda, and Pavon 2011; J. J. Ma et al. 2009; Massanyi et al. 2014; Narin and Soylak 2003; Soylak and Yilmaz 2010; Tuzen et al. 2009).”
BackgroundMethodInfluential
Metadata
- Authors
- Ma, J. J., Du, X., Zhang, J. W., Li, J. C., & Wang, L. Z.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2009-12-15
- Volume
- 80
- Issue
- 2
- Pages
- 980-984
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W1969435070
- Cited by
- 92
- References
- 4
- FWCI
- 7.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-assisted emulsification–microextraction combined with flame atomic absorption spectrometry for determination of trace cadmium in water samples. https://app.cochat.ai/papers/10.1016/j.talanta.2009.08.029
- The paper
- Ma, J. J., Du, X., Zhang, J. W., Li, J. C., & Wang, L. Z. (2009). Ultrasound-assisted emulsification–microextraction combined with flame atomic absorption spectrometry for determination of trace cadmium in water samples. Talanta. https://doi.org/10.1016/j.talanta.2009.08.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.