The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A novel solidified floating organic drop microextraction based on ultrasound-dispersion for separation and preconcentration of palladium in aqueous samples
Abstract
A new method of solidified floating organic drop microextraction, based on ultrasound-dispersion prior to flame atomic absorption spectrometry was successfully used for separation and enrichment of trace amounts of palladium in aqueous samples. In this method, palladium (II) was extracted into the fine droplets of 1-undecanol after chelate formation with the water soluble ligand, ammonium pyrrolidinedithiocarbamate. The fine droplets of 1-undecanol were made and dispersed as a cloud in the aqueous sample with the help of ultrasonic waves. Several variable factors that influence the extraction and complex formation, such as pH, concentration of ammonium pyrrolidinedithiocarbamate, sonication time, centrifuging time, type and volume of the extracting solvent were optimized. Under the optimized conditions, a detection limit of 0.60 ng mL(-1) and a good relative standard deviation of +/-2% at 10 ng mL(-1) were obtained (n=7). The proposed method was applied to well water, tap water, wastewater and synthetic samples and spiked recoveries were in the range of 97-105%. The results showed that solidified floating organic drop microextraction based on ultrasound-dispersion combined with flame atomic absorption spectrometry was a rapid, simple, sensitive, low cost, minimum organic solvent consumption and efficient analytical method for the separation and determination of trace amounts of palladium ion.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Mohamadi et al [37] proposed a ultrasound-assisted emulsification-microextraction (USAEME) method based on solidified floating organic drop microextraction for the analysis of palladium in aqueous samples by FAAS.”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [37]
In the citing paper
“recoveries were in the range of 97%-105%.”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [37]
In the citing paper
“the LOD was 0.6 μ g L -1”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [37]
In the citing paper
“The analytical curve was linear in a concentration range of 2.0-400 μ g L -1”
From Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop (2010) · cites this paper as [37]
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Cited by
Sorted by citations
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Developments in Liquid-phase Microextraction Method Based on Solidification of Floating Organic Drop
WANG, Y.-Y., ZHAO, G.-Y., CHANG, Q.-Y., ZANG, X.-H., WANG, C., & WANG, Z. (2010) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(09)60073-6 · Cited by 31
Metadata
- Authors
- Mohamadi, M., & Mostafavi, A.
- Affiliations
- Shahid Bahonar University of Kerman (IR)
- Corresponding author
- Mostafavi, A.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2010-04-15
- Volume
- 81
- Issue
- 1-2
- Pages
- 309-313
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W1965409153
- Cited by
- 91
- References
- 1
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 2 · 2018: 3 · 2017: 9 · 2016: 6 · 2015: 9 · 2014: 7 · 2013: 14 · 2012: 11
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Inorganic Chemistry › Radioactive element chemistry and processing
- Keywords
- solidified floating organic drop microextraction, ultrasonic dispersion, palladium determination, trace metal preconcentration, pyrrolidine dithiocarbamate, 1-undecanol, aqueous sample, wastewater, well water, tap water, flame atomic absorption spectrometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review