Cited by 91Analytical chemistry methods developmentElectrochemical Analysis and ApplicationsRadioactive element chemistry and processing

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A novel solidified floating organic drop microextraction based on ultrasound-dispersion for separation and preconcentration of palladium in aqueous samples

Mohamadi, M., Mostafavi, A.·2010·Talanta

Abstract

A new method of solidified floating organic drop microextraction, based on ultrasound-dispersion prior to flame atomic absorption spectrometry was successfully used for separation and enrichment of trace amounts of palladium in aqueous samples. In this method, palladium (II) was extracted into the fine droplets of 1-undecanol after chelate formation with the water soluble ligand, ammonium pyrrolidinedithiocarbamate. The fine droplets of 1-undecanol were made and dispersed as a cloud in the aqueous sample with the help of ultrasonic waves. Several variable factors that influence the extraction and complex formation, such as pH, concentration of ammonium pyrrolidinedithiocarbamate, sonication time, centrifuging time, type and volume of the extracting solvent were optimized. Under the optimized conditions, a detection limit of 0.60 ng mL(-1) and a good relative standard deviation of +/-2% at 10 ng mL(-1) were obtained (n=7). The proposed method was applied to well water, tap water, wastewater and synthetic samples and spiked recoveries were in the range of 97-105%. The results showed that solidified floating organic drop microextraction based on ultrasound-dispersion combined with flame atomic absorption spectrometry was a rapid, simple, sensitive, low cost, minimum organic solvent consumption and efficient analytical method for the separation and determination of trace amounts of palladium ion.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2009.12.004

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

Sorted by citations

See all 91

Metadata

Authors
Mohamadi, M., & Mostafavi, A.
Affiliations
Shahid Bahonar University of Kerman (IR)
Corresponding author
Mostafavi, A.
Venue
Talanta
Publisher
Elsevier BV
Published
2010-04-15
Volume
81
Issue
1-2
Pages
309-313
ISSN
0039-9140 (ISSN-L)
OpenAlex
W1965409153
Cited by
91
References
1
Citations by year
2026: 1 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 2 · 2018: 3 · 2017: 9 · 2016: 6 · 2015: 9 · 2014: 7 · 2013: 14 · 2012: 11
FWCI
8.44
Type
journal article
Language
en
Open access
closed
Locations
  • Talanta (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Chemistry › Inorganic Chemistry › Radioactive element chemistry and processing
Keywords
solidified floating organic drop microextraction, ultrasonic dispersion, palladium determination, trace metal preconcentration, pyrrolidine dithiocarbamate, 1-undecanol, aqueous sample, wastewater, well water, tap water, flame atomic absorption spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review