Directly suspended droplet microextraction combined with single drop back-extraction as a new approach for sample preparation compatible with capillary electrophoresis
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A simple and novel method of directly suspended droplet microextraction (DSDME) combined with single drop back-extraction prior to capillary electrophoresis (CE) measurement is developed. In this technique, DSDME was firstly carried out under the maximum stirring rate for a desired time. Then, an aqueous droplet as back-extractive phase suspended at the needle tip was immersed in droplet of organic phase for back-extracted. After extraction, the aqueous droplet was transferred into a suitable vial and injected into CE for analysis. Three alkaloids were selected as model compounds for developing and evaluating the method performance. Under the optimum conditions, the enrichment factors ranged from 231 to 524. The relative standard deviations for five replicates were in the range of 4.8-8.1%. The calibration graph was linear in the range of 20-1000 ng mL(-1) yielding correlation coefficients higher than 0.9983. The limit of detections varied from 8.1 to 14.1 ng mL(-1). Human urine samples were spiked with three alkaloids standard to assess the matrix effects and satisfactory results were obtained. The advantages of this method are simplicity of operation, rapid detection, low cost, high enrichment factor and little solvent consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Cited by
Advances in solvent-microextraction techniques
Kokosa, J. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.09.020 · Cited by 225
Trends in liquid-phase microextraction, and its application to environmental and biological samples
Han, D., & Row, K. H. (2012) · Microchimica Acta · doi:10.1007/s00604-011-0678-0 · Cited by 175
“DSDME also can be combined with CE for analyzing three alkaloids [135].”
BackgroundRecent achievements in solidified floating organic drop microextraction
Viñas, P., Campillo, N., & Andruch, V. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.02.005 · Cited by 99
Metadata
- Authors
- Gao, W., Chen, G., Chen, T., Zhang, X., Chen, Y., & Hu, Z.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2011-02
- Volume
- 83
- Issue
- 5
- Pages
- 1673-1679
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2086995324
- Cited by
- 35
- References
- 3
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Directly suspended droplet microextraction combined with single drop back-extraction as a new approach for sample preparation compatible with capillary electrophoresis. https://app.cochat.ai/papers/10.1016/j.talanta.2010.11.066
- The paper
- Gao, W., Chen, G., Chen, T., Zhang, X., Chen, Y., & Hu, Z. (2011). Directly suspended droplet microextraction combined with single drop back-extraction as a new approach for sample preparation compatible with capillary electrophoresis. Talanta. https://doi.org/10.1016/j.talanta.2010.11.066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.