Dispersive liquid–liquid microextraction and preconcentration of thallium species in water samples by two ionic liquids applied as ion-pairing reagent and extractant phase
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In the present work, a simple and highly sensitive analytical methodology for determination of Tl(+) and Tl(3+) species, based on the use of modern and non-volatile solvents, such as ionic liquids (ILs), was developed. Initially, Tl(+) was complexed by iodide ion at pH 1 in diluted sulfuric acid solution. Then, tetradecyl(trihexyl)phosphonium chloride ionic liquid (CYPHOS(®) IL 101) was used as ion-pairing reagent and a dispersive liquid-liquid microextraction (DLLME) procedure was developed by dispersing 60 mg of 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6) mim][PF(6)] with 500 μL of ethanol in the aqueous solution. After the microextraction procedure was finished, the final IL phase was solubilized in methanol and directly injected into the graphite furnace of an electrothermal atomic absorption spectrometer (ETAAS). An extraction efficiency of 77% and a sensitivity enhancement factor of 100 were obtained with only 5.00 mL of sample. The limit of detection (LOD) was 3.3 ng L(-1) Tl while the relative standard deviation (RSD) was 5.3% (at 0.4 μg L(-1) Tl and n=10), calculated from the peak height of absorbance signals. The method was finally applied to determine Tl species in tap and river water samples after separation of Tl(3+) species. To the best of our knowledge, this work reports the first application of ILs for Tl extraction and separation in the analytical field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Chen, Y., Guo, Z., Wang, X., & Qiu, C. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.10.026 · Cited by 316
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Cited by
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
“It is a remarkable that a significant number of works regarding metals utilize certified reference materials to validate their ILDLLME methods [43,46,47,50,65,67,91,93,94,97].”
BackgroundBelzile, N., & Chen, Y.-W. (2017) · Applied Geochemistry · doi:10.1016/j.apgeochem.2017.06.013 · Cited by 258
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Metadata
- Authors
- Escudero, L. B., Berton, P., Martinis, E. M., Olsina, R. A., & Wuilloud, R. G.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2012-01
- Volume
- 88
- Pages
- 277-283
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2072460301
- Cited by
- 59
- References
- 3
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.