Automatic determination of copper by in-syringe dispersive liquid–liquid microextraction of its bathocuproine-complex using long path-length spectrophotometric detection
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The recently proposed concept of automatic in-syringe dispersive liquid-liquid microextraction was successfully applied to the determination of copper in environmental water samples. Bathocuproine was added to the organic phase as a selective reagent, resulting in the formation of a complex with copper. Dispersion was achieved by aspiration of the organic phase and then the watery phase into the syringe as rapidly as possible. After aggregation of the solvent droplets at the head of the syringe, the organic phase was pushed into a liquid waveguide capillary cell for highly sensitive spectrophotometric detection. The entire analytical procedure was carried out automatically on a multisyringe flow-injection analysis platform and a copper determination was accomplished in less than 220 s. A limit of detection of 5 nmol L(-1) was achieved at an extraction efficiency >90% and a preconcentration factor of 30. A linear working range for concentrations of up to 500 nmol L(-1) and an average standard deviation of 7% in peak height were found. The method proved to be well-suited for the determination of copper in water samples, with an average analyte recovery of 100.6%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Solvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Developments in hollow fibre-based, liquid-phase microextraction
Rasmussen, K. E., & Pedersen-Bjergaard, S. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(04)00105-0 · Cited by 520
Anthemidis, A. N., & Ioannou, K.-I. G. (2009) · Talanta · doi:10.1016/j.talanta.2009.03.005 · Cited by 258
One-step in-syringe ionic liquid-based dispersive liquid–liquid microextraction
Cruz-Vera, M., Lucena, R., Cárdenas, S., & Valcárcel, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.07.040 · Cited by 154
Automated on-line dispersive liquid–liquid microextraction based on a sequential injection system
Andruch, V., Acebal, C. C., Škrlíková, J., Sklenářová, H., Solich, P., Balogh, I. S., Billes, F., & Kocúrová, L. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.09.006 · Cited by 115
Self-citation
Cited by
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
“The same extraction system combined with spectrophotometric detection for the determination of phenol index and copper was applied [188, 190].”
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Self-citationMetal applications of liquid-phase microextraction
Aguirre, M. Á., Baile, P., Vidal, L., & Canals, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.032 · Cited by 67
Guo, L., Tan, S., Li, X., & Lee, H. K. (2016) · Journal of Chromatography A · doi:10.1016/j.chroma.2016.02.008 · Cited by 64
Metadata
- Authors
- Horstkotte, B., Alexovič, M., Maya, F., Duarte, C. M., Andruch, V., & Cerdá, V.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2012-09
- Volume
- 99
- Pages
- 349-356
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2000680634
- Cited by
- 79
- References
- 6
- FWCI
- 10.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic determination of copper by in-syringe dispersive liquid–liquid microextraction of its bathocuproine-complex using long path-length spectrophotometric detection. https://app.cochat.ai/papers/10.1016/j.talanta.2012.05.063
- The paper
- Horstkotte, B., Alexovič, M., Maya, F., Duarte, C. M., Andruch, V., & Cerdá, V. (2012). Automatic determination of copper by in-syringe dispersive liquid–liquid microextraction of its bathocuproine-complex using long path-length spectrophotometric detection. Talanta. https://doi.org/10.1016/j.talanta.2012.05.063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.