Screen-printed electrode based electrochemical detector coupled with ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction for determination of mercury in water samples
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
A novel approach is presented, whereby gold nanostructured screen-printed carbon electrodes (SPCnAuEs) are combined with in-situ ionic liquid formation dispersive liquid-liquid microextraction (in-situ IL-DLLME) and microvolume back-extraction for the determination of mercury in water samples. In-situ IL-DLLME is based on a simple metathesis reaction between a water-miscible IL and a salt to form a water-immiscible IL into sample solution. Mercury complex with ammonium pyrrolidinedithiocarbamate is extracted from sample solution into the water-immiscible IL formed in-situ. Then, an ultrasound-assisted procedure is employed to back-extract the mercury into 10 µL of a 4 M HCl aqueous solution, which is finally analyzed using SPCnAuEs. Sample preparation methodology was optimized using a multivariate optimization strategy. Under optimized conditions, a linear range between 0.5 and 10 µg L(-1) was obtained with a correlation coefficient of 0.997 for six calibration points. The limit of detection obtained was 0.2 µg L(-1), which is lower than the threshold value established by the Environmental Protection Agency and European Union (i.e., 2 µg L(-1) and 1 µg L(-1), respectively). The repeatability of the proposed method was evaluated at two different spiking levels (3 and 10 µg L(-1)) and a coefficient of variation of 13% was obtained in both cases. The performance of the proposed methodology was evaluated in real-world water samples including tap water, bottled water, river water and industrial wastewater. Relative recoveries between 95% and 108% were obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · cited 2×
“One of the most popular LPME technique is dispersive liquid-liquid microextraction (DLLME) [19] which has”
MethodIonic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256 · cited 1×
“Numerous modifications of the original DLLME procedure [19] have been reported up to now [21] including the use of new extractant solvents such as ionic liquids (ILs) [22].”
MethodLiquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221 · cited 1×
“Liquid-phase microextraction (LPME) [18] appeared in the latest nineties offering undoubted advantages as miniaturized extraction techniques, such as simplicity, easiness to handle, low sample and solvent consumptions, and an important reduction of residues generated.”
BackgroundYao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204 · cited 2×
“Within the use of ILs, a novel methodology called in-situ IL formation dispersive liquid-liquid microextraction (in-situ IL-DLLME) [23,24] has recently been developed.”
MethodPena-Pereira, F., Lavilla, I., Bendicho, C., Vidal, L., & Canals, A. (2009) · Talanta · doi:10.1016/j.talanta.2008.12.003 · Cited by 143 · cited 2×
“Different LPME techniques including single-drop microextraction [25,26], DLLME [27–29], in-situ IL-DLLME [23] and task-specific IL ultrasound-assisted DLLME [30] have been employed for the determination and speciation of mercury in water samples.”
BackgroundMethodSelf-citationGao, Z., & Ma, X. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.019 · Cited by 119 · cited 2×
“Different LPME techniques including single-drop microextraction [25,26], DLLME [27–29], in-situ IL-DLLME [23] and task-specific IL ultrasound-assisted DLLME [30] have been employed for the determination and speciation of mercury in water samples.”
BackgroundMethodJia, X., Han, Y., Liu, X., Duan, T., & Chen, H. (2011) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2010.12.003 · Cited by 119
Research works printed but not linked: 22
- Leopold, 2009, TrAC Trends Anal. Chem., 28, 426, 10.1016/j.trac.2009.02.004 · DOI
- Gao, 2013, TrAC Trends Anal. Chem., 51, 1, 10.1016/j.trac.2013.05.010 · doi:10.1016/j.trac.2013.05.010
- Martín-Yerga, 2013, Talanta, 116, 1091, 10.1016/j.talanta.2013.07.056 · DOI · Paper page
- Bernalte, 2011, Anal. Chim. Acta, 689, 60, 10.1016/j.aca.2011.01.042 · DOI
- Arduini, 2011, Electrochim. Acta, 56, 4209, 10.1016/j.electacta.2011.01.094 · doi:10.1016/j.electacta.2011.01.094
- Niu, 2011, Anal. Sci., 27, 1237, 10.2116/analsci.27.1237 · doi:10.2116/analsci.27.1237
- Aragay, 2011, J. Mater. Chem., 21, 4326, 10.1039/c0jm03751f · DOI
- Mandil, 2010, Microchim. Acta, 170, 299, 10.1007/s00604-010-0329-x · doi:10.1007/s00604-010-0329-x
- Laschi, 2006, Sens. Actuators B, 114, 460, 10.1016/j.snb.2005.05.028 · DOI
- Martín-Yerga, 2012, Sens. Actuators B, 165, 143, 10.1016/j.snb.2012.02.031 · DOI
- Bernalte, 2012, Sens. Actuators B, 161, 669, 10.1016/j.snb.2011.10.088 · doi:10.1016/j.snb.2011.10.088
- Khaled, 2010, Int. J. Electrochem. Sci., 5, 158, 10.1016/S1452-3981(23)15274-6 · doi:10.1016/s1452-3981(23)15274-6
- Campbell, 2010, Anal. Bioanal. Chem., 396, 241, 10.1007/s00216-009-3063-7 · DOI · Paper page
- Kokosa, 2013, TrAC Trends Anal. Chem., 43, 2, 10.1016/j.trac.2012.09.020 · DOI · Paper page
- Baghdadi, 2009, Anal. Chim. Acta, 634, 186, 10.1016/j.aca.2008.12.017 · DOI · Paper page
- Bagheri, 2009, J. Hazard. Mater., 165, 353, 10.1016/j.jhazmat.2008.09.128 · DOI
- Li, 2011, Microchim. Acta, 175, 301, 10.1007/s00604-011-0679-z · DOI
- Stanisz, 2013, Microchem. J., 110, 28, 10.1016/j.microc.2013.01.006 · DOI
- Fernández, 2014, Anal. Bioanal. Chem., 406, 2197, 10.1007/s00216-013-7415-y · DOI
- Martínez-Paredes, 2009, Electrochim. Acta, 54, 4801, 10.1016/j.electacta.2009.03.085 · doi:10.1016/j.electacta.2009.03.085
- Heyden, 1995, Anal. Chim. Acta, 316, 15, 10.1016/0003-2670(95)00349-5 · DOI
- Fabre, 2000, J. Chromatogr. A, 897, 329, 10.1016/S0021-9673(00)00794-9 · DOI
Cited by
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“When the obtained enriched phase is not compatible with the instrumentation used in the analysis, an additional step must be included in the whole procedure; for example, BE for liquid chromatography (LC) (244, 246, 259, 277, 446, 595, 994, 1123), capillary electrophoresis (CE) (330, 468, 771, 989, 1425), inductively…”
BackgroundMethodMetal applications of liquid-phase microextraction
Aguirre, M. Á., Baile, P., Vidal, L., & Canals, A. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.032 · Cited by 67
Self-citationShishov, A., Volodina, N., Nechaeva, D., Gagarinova, S., & Bulatov, A. (2018) · RSC Advances · doi:10.1039/c8ra07300g · Cited by 63
Metadata
- Authors
- Fernández, E., Vidal, L., Martín-Yerga, D., Blanco, M. D. C., Canals, A., & Costa-García, A.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2015-04
- Volume
- 135
- Pages
- 34-40
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2024028819
- Cited by
- 46
- References
- 8
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- Spanish Ministry of Science and Innovation (CTQ2011-23968, CTQ2011-24560)
- Generalitat Valenciana (Spain) (ACOMP/2013/072, PROMETEO/2013/038, GV/2014/096)
- University of Alicante (Spain) (GRE12-45)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Screen-printed electrode based electrochemical detector coupled with ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction for determination of mercury in water samples. https://app.cochat.ai/papers/10.1016/j.talanta.2014.11.069
- The paper
- Fernández, E., Vidal, L., Martín-Yerga, D., Blanco, M. D. C., Canals, A., & Costa-García, A. (2015). Screen-printed electrode based electrochemical detector coupled with ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction for determination of mercury in water samples. Talanta. https://doi.org/10.1016/j.talanta.2014.11.069
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.