Cited by 53Microfluidic and Capillary Electrophoresis ApplicationsAdvanced Proteomics Techniques and ApplicationsMass Spectrometry Techniques and Applications

Integrated strong cation-exchange hybrid monolith coupled with capillary zone electrophoresis and simultaneous dynamic pH junction for large-volume proteomic analysis by mass spectrometry

Open access
Zhang, Zhenbin, Sun, Liangliang, Zhu, Guijie, Yan, Xiaojing, Dovichi, Norman J.·2015·Talanta

Abstract

A sulfonate-silica hybrid strong cation-exchange (SCX) monolith was synthesized at the proximal end of a capillary zone electrophoresis column and used for on-line solid-phase extraction (SPE) sample preconcentration. Sample was prepared in an acidic buffer and deposited onto the SCX-SPE monolith and eluted using a basic buffer. Electrophoresis was performed in an acidic buffer. This combination of buffers results in formation of a dynamic pH junction, which allows use of relatively large elution buffer volume while maintaining peak efficiency and resolution. All experiments were performed with a 50 µm ID capillary, a 1cm long SCX-SPE monolith, a 60cm long separation capillary, and a electrokinetically pumped nanospray interface. The volume of the capillary is 1.1 µL. By loading 21 µL of a 1×10(-7) M angiotensin II solution, an enrichment factor of 3000 compared to standard electrokinetic injection was achieved on this platform while retaining efficient electrophoretic performance (N=44,000 plates). The loading capacity of the sulfonate SCX hybrid monolith was determined to be ~15 pmol by frontal analysis with 10(-5) M angiotensin II. The system was also applied to the analysis of a 10(-4) mg/mL bovine serum albumin tryptic digest; the protein coverage was 12% and 11 peptides were identified. Finally, by loading 5.5 µL of a 10(-3) mg/mL E. coli digest, 109 proteins and 271 peptides were identified in a 20 min separation; the median separation efficiency generated by these peptides was 25,000 theoretical plates.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.talanta.2015.01.040

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • On-line SPE preconcentration with a sulfonate-silica hybrid SCX monolith and dynamic pH junction enabled microliter-level injections with separation efficiency over 25,000 theoretical plates.

    “This approach enabled injections at μL levels with a separation efficiency of over 25,000 theoretical plates.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 38 · Cited by 53

Authors
Zhang, Z., Sun, L., Zhu, G., Yan, X., & Dovichi, N. J.
Affiliations
University of Notre Dame (US)
Venue
Talanta
Publisher
Elsevier BV
Published
2015-06
Volume
138
Pages
117-122
ISSN
0039-9140 (ISSN-L)
OpenAlex
W2050985492
Cited by
53
References
38
Citations by year
2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 9 · 2017: 10 · 2016: 10 · 2015: 8 · 2013: 1
FWCI
6.13
Type
journal article
Language
en
Open access
Locations
  • Talanta (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institutes of Health (R01GM096767)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
Keywords
capillary zone electrophoresis, dynamic pH junction, on-line solid-phase extraction, preconcentration, electrokinetic injection, proteomics, angiotensin II, bovine serum albumin, peptide identification
MeSH terms
Animals, Cation Exchange Resins, Cattle, Chromatography, Ion Exchange, Hydrogen-Ion Concentration, Peptide Fragments, Serum Albumin, Bovine, Silicon Dioxide, Sulfhydryl Compounds, Electrophoresis, Capillary, Spectrometry, Mass, Electrospray Ionization, Escherichia coli Proteins, Proteomics, Solid Phase Extraction, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review