In situ generation of hydrophobic magnetic ionic liquids in stir bar dispersive liquid-liquid microextraction coupled with headspace gas chromatography
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
For the first time, an in situ stir bar dispersive liquid-liquid microextraction approach has been developed and coupled with headspace gas chromatography-mass spectrometry for the determination of a group of organic pollutants. The method exploits a new generation of magnetic ionic liquids (MILs) that contain paramagnetic cations based on Ni2+ or Co2+ metal centers coordinated with either N-butylimidazole or N-octylimidazole ligands and chloride anions. The reactants are added to an aqueous solution containing a high field neodymium rod magnet, followed by the addition of the bis[(trifluoromethyl)sulfonyl]imide anion that promotes a metathesis reaction for the in situ generation of a hydrophobic MIL. Concurrently, a high stirring rate is maintained to exceed the magnetic field of the rod magnet and disperse the generated MIL in the sample solution. When stirring is stopped, the MIL coats the rod magnet due to its paramagnetic nature, facilitating the MIL transfer and subsequent desorption and analysis. Under optimum conditions, the method required a 2.5-18% (w/v) aqueous solution of sodium chloride, 10 mL of sample, 20 or 30 mg of MIL, the addition of a small volume of dispersive solvent, and stirring for 5-7.5 min, depending on the MIL. The method provided limits of detection (LODs) down to 10 μg L-1, adequate reproducibility (with relative standard deviation values lower than 10% for a spiked level of 80 μg L-1), and relative recoveries between 72.5% and 102%. Furthermore, the method was successfully applied in the analysis of tap and mineral water.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances of ionic liquids in analytical Chemistry
Trujillo-Rodríguez, M. J., Nan, H., Varona, M., Emaus, M. N., Souza, I. D., & Anderson, J. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04710 · Cited by 248
Self-citationBeyond dispersive liquid–liquid microextraction
Leong, M.-I., Fuh, M.-R., & Huang, S.-D. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.02.021 · Cited by 241
Magnetic ionic liquids in analytical chemistry: A review
Clark, K. D., Nacham, O., Purslow, J. A., Pierson, S. A., & Anderson, J. L. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.011 · Cited by 222
Self-citationYao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Self-citationBenedé, J. L., Chisvert, A., Giokas, D. L., & Salvador, A. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.08.024 · Cited by 133
Magnetic ionic liquids as extraction solvents in vacuum headspace single-drop microextraction
Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Talanta · doi:10.1016/j.talanta.2017.05.021 · Cited by 81
Self-citation
Cited by
Recent advances of ionic liquids in sample preparation
Feng, J., Loussala, H. M., Han, S., Ji, X., Li, C., & Sun, M. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115833 · Cited by 164
Ionic liquids in the microextraction techniques: The influence of ILs structure and properties
Yavir, K., Konieczna, K., Marcinkowski, Ł., & Kloskowski, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.115994 · Cited by 134
Pacheco-Fernández, I., González-Martín, R., e Silva, F. A., Freire, M. G., & Pino, V. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.08.022 · Cited by 69
“When dealing with GC coupled with different detectors, mainly MS, the analytes were thermally desorbed from the hydrophobic IL using a headspace sampler [161,167,178] or a thermal desorption unit [159].”
BackgroundMethod
Metadata
- Authors
- Trujillo-Rodríguez, M. J., & Anderson, J. L.
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2019-05
- Volume
- 196
- Pages
- 420-428
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W2907502501
- Cited by
- 41
- References
- 6
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In situ generation of hydrophobic magnetic ionic liquids in stir bar dispersive liquid-liquid microextraction coupled with headspace gas chromatography. https://app.cochat.ai/papers/10.1016/j.talanta.2018.12.071
- The paper
- Trujillo-Rodríguez, M. J., & Anderson, J. L. (2019). In situ generation of hydrophobic magnetic ionic liquids in stir bar dispersive liquid-liquid microextraction coupled with headspace gas chromatography. Talanta. https://doi.org/10.1016/j.talanta.2018.12.071
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.