The DOI matches its Crossref record; 211 of the 211 references it cites were found in a registry or an index.
Electrochemical vitamin sensors: A critical review
Abstract
This paper reviews the recent development of electrochemical sensors for the detection of vitamins over the past three years. Vitamins present in natural foodstuffs are a group of organic compounds that are indispensable to maintain human health. While they are only present in minute amounts, they still play a significant role in healthy metabolism. The deficiency of vitamins in the human body often leads to numerous diseases. Because the human body cannot synthesize most vitamins, it is necessary to obtain them from dietary sources. For these reasons, the detection of vitamins has gained widespread attention in recent years. As it is well known, almost all vitamins are electrochemically active. Based on the electrochemical oxidation or reduction reaction of the vitamins in an electrolyte, electrochemical sensors can obtain the concentration of the vitamins by measurement of the current at the working electrode. Electrochemical sensors for detecting water-soluble vitamins, such as vitamin B 1, vitamin B 2, vitamin B 6, vitamin B 9, vitamin B 12, and vitamin C are discussed in detail. A comprehensive overview of electrochemical sensors for detecting fat-soluble vitamins, such as vitamin A, vitamin D, vitamin E, and vitamin K, is also provided. Furthermore, the strategies employed and the performance of the electrochemical sensors for detecting vitamins are described. Finally, current challenges and future prospects of electrochemical sensors for the detection of vitamins are discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the recent innovations in electrode nanomaterials improved both sensitivity and selectivity [239] and yielded one of the most sensitive techniques for L-ascorbic acid detection in biological materials.”
From Vitamin C-Sources, Physiological Role, Kinetics, Deficiency, Use, Toxicity, and Determination (2021) · cites this paper as [239]
In the citing paper
“Moreover, the recent innovations in electrode nanomaterials improved both sensitivity and selectivity [239] and yielded one of the most sensitive techniques for L-ascorbic acid detection in biological materials.”
From Vitamin C-Sources, Physiological Role, Kinetics, Deficiency, Use, Toxicity, and Determination (2021) · cites this paper as [239]
Citations
Cites
2014 International Conference on Computational Science
Abramson, D., Lees, M., Krzhizhanovskaya, V. V., Dongarra, J. J., & Sloot, P. M. A. (2014) · UvA-DARE (University of Amsterdam) · Cited by 1,013
Vitamin D for skeletal and non-skeletal health: What we should know
Charoenngam, N., Shirvani, A., & Holick, M. F. (2019) · Journal of Clinical Orthopaedics and Trauma · doi:10.1016/j.jcot.2019.07.004 · Cited by 329
Alginate/chitosan nanoparticles for encapsulation and controlled release of vitamin B2
Azevedo, M. A., Bourbon, A. I., Vicente, A. A., & Cerqueira, M. Â. (2014) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2014.05.036 · Cited by 267
Sikkens, E. C. M., Cahen, D. L., Koch, A. D., Braat, H., Poley, J., Kuipers, E. J., & Bruno, M. J. (2013) · Pancreatology · doi:10.1016/j.pan.2013.02.008 · Cited by 198
Ji, D., Liu, Z. L., Liu, L., Low, S. S., Lu, Y., Yu, X., Zhu, L., Li, C., & Liu, Q. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.07.074 · Cited by 191
Jamali, T., Karimi‐Maleh, H., & Khalilzadeh, M. A. (2014) · LWT · doi:10.1016/j.lwt.2014.01.023 · Cited by 170
Sequential determination of fat- and water-soluble vitamins in green leafy vegetables during storage
Santos, J., Mendiola, J. A., Oliveira, M. B. P. P., et al. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.04.067 · Cited by 163
Madhuvilakku, R., Alagar, S., Mariappan, R., & Piraman, S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.06.126 · Cited by 152
Şavk, A., Özdil, B., Demirkan, B., et al. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.01.113 · Cited by 147
Taguchi, K., Fukusaki, E., & Bamba, T. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.08.003 · Cited by 145
Rapid determination of vitamin B2 (riboflavin) in plasma by HPLC
Petteys, B. J., & Frank, E. L. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.08.037 · Cited by 138
Carbon dots-modified chitosan based electrochemical biosensing platform for detection of vitamin D
Sarkar, T., Bohidar, H. B., & Solanki, P. R. (2017) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2017.12.122 · Cited by 126
Tığ, G. A. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.11.008 · Cited by 123
Manna, P., & Kalita, J. (2016) · Nutrition · doi:10.1016/j.nut.2016.01.011 · Cited by 118
Simultaneous monitoring of glucose and uric acid on a single test strip with dual channels
Guo, J., & Ma, X. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.026 · Cited by 118
Self-citationPinheiro-Sant'Ana, H. M., Guinazi, M., Oliveira, D. D. S., et al. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.09.067 · Cited by 117
Kumar, M., Swamy, B. E. K., Reddy, S., et al. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.01.019 · Cited by 116
Sá, É. S., Silva, P. S., Jost, C. L., et al. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.11.136 · Cited by 115
Effect of vitamin K2 on type 2 diabetes mellitus: A review
Li, Y., Chen, J. P., Duan, L., & Li, S. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.11.020 · Cited by 106
Hu, B., Liu, Y., Wang, Z., Song, Y., Wang, M., Zhang, Z., & Liu, C. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.02.093 · Cited by 105
Wong, A., Santos, A. M., Silva, T. A., et al. (2018) · Talanta · doi:10.1016/j.talanta.2018.02.066 · Cited by 103
Hashemi, S. A., Mousavi, S. M., Bahrani, S., et al. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.02.018 · Cited by 103
Smartphone-Powered Electrochemical Biosensing Dongle for Emerging Medical IoTs Application
Guo, J. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2777145 · Cited by 102
Self-citationChauhan, D., Gupta, P. K., & Solanki, P. R. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.07.036 · Cited by 101
Ensafi, A. A., Heydari‐Bafrooei, E., & Amini, M. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.050 · Cited by 100
Deficiency of fat-soluble vitamins in chronic pancreatitis: A systematic review and meta-analysis
Martínez-Moneo, E., Stigliano, S., Hedström, A., Kaczka, A., Malvik, M., Waldthaler, A., Maisonneuve, P., Simon, P., & Capurso, G. (2016) · Pancreatology · doi:10.1016/j.pan.2016.09.008 · Cited by 99
Ganesan, M., Rajkumar, C., Chen, S.-M., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.10.145 · Cited by 98
Markopoulou, C. K., Kagkadis, K. A., & Koundourellis, J. E. (2002) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/s0731-7085(02)00456-9 · Cited by 97
Roushani, M., & Shahdost-fard, F. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.10.131 · Cited by 96
Li, C., Yang, Q., Wang, X., et al. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2020.126575 · Cited by 96
Mazloum‐Ardakani, M., Sheikh‐Mohseni, M. A., Abdollahi‐Alibeik, M., & Benvidi, A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.04.071 · Cited by 95
A novel ratiometric electrochemical biosensor for sensitive detection of ascorbic acid
Wang, L., Gong, C., Shen, Y., et al. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.11.100 · Cited by 95
Voltammetric sensing of biomolecules at carbon based electrode interfaces: A review
Dhanjai, D., Sinha, A., Lu, X., et al. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.11.010 · Cited by 95
Zou, C., Zhong, J., Li, S., Wang, H., Wang, J., Yan, B., & Du, Y. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.10.020 · Cited by 92
Hussain, S., Zaidi, S. A., Vikraman, D., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111330 · Cited by 92
Arabali, V., Ebrahimi, M., Abbasghorbani, M., Gupta, V. K., Farsi, M., Ganjali, M. R., & Karimi, F. (2015) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2015.10.001 · Cited by 91
Nezamzadeh‐Ejhieh, A., & Pouladsaz, P. (2013) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2013.09.044 · Cited by 91
Bioinspired carbon quantum dots for sensitive fluorescent detection of vitamin B12 in cell system
Wang, M., Liu, Y., Ren, G., et al. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.057 · Cited by 91
Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
Mehmeti, E., Stanković, D. M., Chaiyo, S., et al. (2016) · Microchimica Acta · doi:10.1007/s00604-016-1789-4 · Cited by 90
Advanced analytical techniques for fat-soluble vitamin analysis
Fanali, C., D’Orazio, G., Fanali, S., & Gentili, A. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.12.001 · Cited by 90
Vidović, S., Jančić–Stojanović, B., Veljković, J., et al. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.06.039 · Cited by 89
Electrochemical determination of folic acid: A short review
Akbar, S., Anwar, A. W., & Kanwal, Q. (2016) · Analytical Biochemistry · doi:10.1016/j.ab.2016.07.002 · Cited by 89
Tigari, G., & Manjunatha, J. G. (2019) · Journal of Analysis and Testing · doi:10.1007/s41664-019-00116-w · Cited by 87
Carlucci, L., Favero, G., Tortolini, C., et al. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.077 · Cited by 84
Nie, T., Xu, J.-K., Lu, L.-M., et al. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.06.057 · Cited by 83
Beitollahi, H., Ivari, S. G., & Torkzadeh‐Mahani, M. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.06.064 · Cited by 83
Determination of Riboflavin at Carbon Nanotube Paste Electrodes Modified with an Anionic Surfactant
Tigari, G., Manjunatha, J. G., Raril, C., et al. (2019) · ChemistrySelect · doi:10.1002/slct.201803191 · Cited by 81
Hareesha, N., & Manjunatha, J. G. (2020) · Journal of the Iranian Chemical Society · doi:10.1007/s13738-020-01876-4 · Cited by 81
Radu, A. I., Kuellmer, M., Giese, B., et al. (2016) · Talanta · doi:10.1016/j.talanta.2016.07.027 · Cited by 80
Chauhan, D., Kumar, R., Panda, A. K., & Solanki, P. R. (2019) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2019.09.017 · Cited by 79
Wang, Q., Si, H., Zhang, L., et al. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.01.012 · Cited by 79
Shahamirifard, S. A., & Ghaedi, M. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111474 · Cited by 76
Isolation and analysis of vitamin B12 from plant samples
Nakos, M., Pepelanova, I., Beutel, S., et al. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.08.037 · Cited by 75
Wang, H., Shou, Y., Zhu, X., et al. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.10.033 · Cited by 74
Anusha, T., Bhavani, K. S., Kumar, J. V. S., et al. (2020) · Diamond and Related Materials · doi:10.1016/j.diamond.2020.107761 · Cited by 74
Au-CuO core-shell nanoparticles design and development for the selective determination of Vitamin B6
Kumar, D. R., Manoj, D., Santhanalakshmi, J., et al. (2015) · Electrochimica Acta · doi:10.1016/j.electacta.2015.07.034 · Cited by 72
Arvand, M., & Dehsaraei, M. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.04.037 · Cited by 71
Recent trends in analytical methods for water-soluble vitamins
Fatima, Z., Jin, X., Zou, Y., et al. (2019) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.05.025 · Cited by 71
Ding, L., Yang, H., Ge, S., & Yu, J. (2017) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.12.015 · Cited by 69
Dinesh, B., Saraswathi, R., & Kumar, A. S. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.02.139 · Cited by 68
Hsu, S.-C., Cheng, H.-T., Wu, P., et al. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.04.021 · Cited by 68
Brahman, P. K., Dar, R. A., & Pitre, K. S. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.11.073 · Cited by 67
Shao, L., Wang, X., Yang, B.-Q., Wang, Q., Tian, Q., Ji, Z., & Zhang, J. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.09.178 · Cited by 67
Rapid diagnostic testing platform for iron and vitamin A deficiency
Lu, Z., O’Dell, D., Srinivasan, B., Rey, E. G., Wang, R., Vemulapati, S., Mehta, S., & Erickson, D. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1711464114 · Cited by 65
Yin, S., Yang, Y., Wu, L., Li, Y., & Sun, C. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.008 · Cited by 65
Revin, S. B., & John, S. A. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.056 · Cited by 64
Recent advances in vitamins analysis by capillary electrophoresis
Wang, X., Li, K., Yao, L., Wang, C., & Schepdael, A. V. (2017) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.07.030 · Cited by 64
Parvin, M. H., Azizi, E., Arjomandi, J., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.168 · Cited by 63
Kuzmanović, D., Khan, M., Mehmeti, E., et al. (2016) · Diamond and Related Materials · doi:10.1016/j.diamond.2016.02.018 · Cited by 61
Sensitive amperometric detection of riboflavin with a whole-cell electrochemical sensor
Yu, Y., Wang, J., Si, R.-W., et al. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.06.053 · Cited by 61
Borah, P. K., Sarkar, A., & Duary, R. K. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2019.03.022 · Cited by 61
Wiring Bacterial Electron Flow for Sensitive Whole-Cell Amperometric Detection of Riboflavin
Si, R.-W., Yang, Y. Z., Yu, Y., et al. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03538 · Cited by 59
Melfi, M. T., Nardiello, D., Cicco, N., et al. (2018) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2018.04.002 · Cited by 59
Vitamin D assays in clinical laboratory: Past, present and future challenges
Atef, S. H. (2017) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2017.02.011 · Cited by 58
Tukimin, N., Abdullah, J., & Sulaiman, Y. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.04.065 · Cited by 58
Puangjan, A., Chaiyasith, S., Taweeporngitgul, W., et al. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.03.040 · Cited by 56
Zhang, Z., Xu, J., Wen, Y., & Wang, T. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.06.029 · Cited by 56
Xun, P., Lin, H., Wang, R., et al. (2019) · Aquaculture · doi:10.1016/j.aquaculture.2019.03.017 · Cited by 54
Sonkar, P. K., Ganesan, V., Gupta, S. K. S., et al. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.11.050 · Cited by 53
Field-amplified sample stacking–sweeping of vitamins B determination in capillary electrophoresis
Dziomba, S., Kowalski, P., & Bączek, T. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.07.068 · Cited by 52
Alpar, N., Pınar, P. T., Yardım, Y., et al. (2017) · Electroanalysis · doi:10.1002/elan.201700077 · Cited by 52
Alonso‐Lomillo, M. A., Domínguez‐Renedo, O., Saldaña-Botín, A., et al. (2017) · Talanta · doi:10.1016/j.talanta.2017.07.015 · Cited by 51
Yan, S., Xi, L., Li, X., et al. (2016) · Microchimica Acta · doi:10.1007/s00604-016-1776-9 · Cited by 50
Porto, L. S., da Silva, D. N., Silva, M. C., et al. (2019) · Electroanalysis · doi:10.1002/elan.201800789 · Cited by 50
Mollaei, M., Ghoreishi, S. M., & Khoobi, A. (2019) · Measurement · doi:10.1016/j.measurement.2019.05.064 · Cited by 50
Asaikkutti, A., Bhavan, P. S., & Vimala, K. (2016) · Aquaculture · doi:10.1016/j.aquaculture.2016.06.014 · Cited by 49
Manoj, D., Rajendran, S., Qin, J., et al. (2019) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2019.01.118 · Cited by 49
Kumar, A., Furtado, V. L., Gonçalves, J. M., et al. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.10.022 · Cited by 49
Tabassum, R., & Gupta, B. D. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.06.030 · Cited by 48
Sangamithirai, D., Munusamy, S., Narayanan, V., et al. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.05.070 · Cited by 48
Liu, S., Jiang, X., & Yang, M. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3562-y · Cited by 48
CdTe quantum dot as a fluorescence probe for vitamin B12 in dosage form
Vaishnavi, E., & Renganathan, R. (2013) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2013.06.068 · Cited by 47
Zhu, Q., Bao, J., Huo, D., et al. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.07.004 · Cited by 47
Ashoka, N. B., Swamy, B. E. K., Jayadevappa, H. P., et al. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.113819 · Cited by 46
Selvarajan, S., Suganthi, A., & Rajarajan, M. (2017) · Surfaces and Interfaces · doi:10.1016/j.surfin.2017.03.008 · Cited by 45
Ejaz, A., & Jeon, S. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.05.193 · Cited by 45
Wong, Y. F., Makahleh, A., Saad, B., et al. (2014) · Talanta · doi:10.1016/j.talanta.2014.07.021 · Cited by 44
Shadjou, N., Hasanzadeh, M., & Omari, A. (2017) · Analytical Biochemistry · doi:10.1016/j.ab.2017.10.011 · Cited by 44
Abellán-Llobregat, A., Vidal, L., Rodríguez‐Amaro, R., et al. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.08.007 · Cited by 43
Kumar, M. A., Lakshminarayanan, V., & Ramamurthy, S. S. (2018) · Comptes Rendus Chimie · doi:10.1016/j.crci.2018.09.015 · Cited by 43
Atta, N. F., Galal, A. M., El-Ads, E. H., et al. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.1981713jes · Cited by 42
Free‐standing and Flexible MoS2/rGO Paper Electrode for Amperometric Detection of Folic Acid
Kıranşan, K. D., & Topç̧u, E. (2018) · Electroanalysis · doi:10.1002/elan.201700778 · Cited by 42
Electrochemical quantification of pyridoxine (VB6) in human blood from other water-soluble vitamins
Rejithamol, R., & Beena, S. (2020) · Chemical Papers · doi:10.1007/s11696-019-01049-5 · Cited by 42
Sýs, M., Švecová, B., Švancara, I., et al. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2017.02.068 · Cited by 41
Selvarajan, S., Suganthi, A., & Rajarajan, M. (2018) · Journal of Physics and Chemistry of Solids · doi:10.1016/j.jpcs.2018.06.005 · Cited by 41
Hei, Y., Li, X., Zhou, X. L., Liu, J., Hassan, M., Zhang, S., Yang, Y. J., Bo, X., Wang, H., & Zhou, M. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.041 · Cited by 40
Zhang, Y., Bala, V., Mao, Z., Chhonker, Y. S., & Murry, D. J. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.03.006 · Cited by 40
Ahmed, S., & Mahmoud, A. M. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.007 · Cited by 39
Li, Y., Jia, Y. F., Zeng, Q., Jiang, X., & Cheng, Z. (2018) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2018.12.002 · Cited by 39
Sangili, A., Veerakumar, P., Chen, S., et al. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3396-7 · Cited by 39
In situ fabrication of CuO nanowire film for high-sensitive ascorbic acid recognition
You, Q., Liu, T., Pang, J., et al. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.05.094 · Cited by 39
Electrochemical Detection of Vitamin D2 and D3 Based on a AuPd Modified Glassy Carbon Electrode
Men, K., Chen, Y., Liu, J., et al. (2017) · International Journal of Electrochemical Science · doi:10.20964/2017.10.15 · Cited by 38
Pereira, D. F., Santana, E. R., Piovesan, J. V., et al. (2020) · Diamond and Related Materials · doi:10.1016/j.diamond.2020.107793 · Cited by 38
Yang, Y., Jo, A., Lee, Y.-M., et al. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.08.089 · Cited by 37
Nigović, B., Mornar, A., Brusač, E., et al. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113450 · Cited by 37
Kumar, D. R., Manoj, D., & Santhanalakshmi, J. (2013) · Analytical Methods · doi:10.1039/c3ay41810c · Cited by 36
Graphene-ceramic hybrid nanofibers for ultrasensitive electrochemical determination of ascorbic acid
Taleb, M., Ivanov, R., Bereznev, S., et al. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2085-7 · Cited by 36
New rotating disk hematite film electrode for riboflavin detection
Gribat, L. C., Babauta, J. T., Beyenal, H., & Wall, N. A. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.05.008 · Cited by 36
Yang, K., Wang, Y., Lu, C., et al. (2017) · Journal of Luminescence · doi:10.1016/j.jlumin.2017.12.038 · Cited by 36
Gao, X., Yue, H., Huang, S., et al. (2017) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2017.12.017 · Cited by 35
Scremin, J., Barbosa, E. C. M., Salamanca‐Neto, C. A. R., Camargo, P. H. C., & Sartori, E. R. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2785-7 · Cited by 35
Mohammadi, S. Z., Beitollahi, H., Dehghan, Z., et al. (2018) · Applied Organometallic Chemistry · doi:10.1002/aoc.4551 · Cited by 35
de Oliveira, G. C., Pereira, L. C., Silva, A. L., et al. (2018) · Journal of Solid State Electrochemistry · doi:10.1007/s10008-018-3897-z · Cited by 34
Lazzarino, G., Longo, S., Amorini, A. M., Di Pietro, V., D’Urso, S., Lazzarino, G., Belli, A., & Tavazzi, B. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.10.053 · Cited by 33
Đurović, A. D., Stojanović, Z. S., Kravić, S., et al. (2019) · Electroanalysis · doi:10.1002/elan.201900532 · Cited by 33
Amini, R., & Asadpour‐Zeynali, K. (2020) · Electroanalysis · doi:10.1002/elan.201900600 · Cited by 33
Shao, L., Zhu, X., Yang, Y., et al. (2016) · Aquaculture · doi:10.1016/j.aquaculture.2016.03.054 · Cited by 32
Raveendran, J., Krishnan, R. G., Nair, B. G., et al. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2391-0 · Cited by 32
Sriramprabha, R., Divagar, M., Ponpandian, N., et al. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0761811jes · Cited by 32
Zhao, Y., Qin, J., Xu, H. F., et al. (2018) · Microchimica Acta · doi:10.1007/s00604-018-3138-2 · Cited by 32
Dokur, E., Gorduk, O., & Şahin, Y. (2020) · Analytical Letters · doi:10.1080/00032719.2020.1728540 · Cited by 32
Woollard, D. C., Bensch, A., Indyk, H. E., & McMahon, A. (2015) · Food Chemistry · doi:10.1016/j.foodchem.2015.10.077 · Cited by 30
Tayade, A. B., Dhar, P., Kumar, J., et al. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.05.062 · Cited by 30
Sánchez‐Hernández, D., Anderson, G. H., Poon, A. N., Pannia, E., Cho, C. E., Huot, P. S. P., & Kubant, R. (2016) · Nutrition Research · doi:10.1016/j.nutres.2016.09.009 · Cited by 30
Behpour, M., Attaran, A. M., Sadiany, M. M., et al. (2015) · Measurement · doi:10.1016/j.measurement.2015.09.009 · Cited by 29
Haldorai, Y., Choe, S. R., Huh, Y. S., et al. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2669-x · Cited by 29
Oberson, J., Campos-Giménez, E., Rivière, J., et al. (2018) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.04.017 · Cited by 29
A Novel Electrochemical Sensor Based on Plastic Antibodies for Vitamin D3 Detection in Real Samples
Kia, S., Bahar, S., & Bohlooli, S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2903090 · Cited by 29
Karthika, A., Suganthi, A., & Rajarajan, M. (2019) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2019.12.009 · Cited by 29
Recent Advances in Electroanalysis of Vitamins
Brunetti, B. (2016) · Electroanalysis · doi:10.1002/elan.201600097 · Cited by 28
γ-Al2O3 nanoparticle catalyst mediated polyaniline gold electrode biosensor for vitamin E
Parvin, M. H., Arjomandi, J., & Lee, J. Y. (2018) · Catalysis Communications · doi:10.1016/j.catcom.2018.03.009 · Cited by 28
Diniz, M. E. R., Dias, N., de Andrade, F. V., Paulo, B. F., & Ferreira, A. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.03.001 · Cited by 28
Kuceki, M., de Oliveira, F. M., Segatelli, M. G., et al. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.04.043 · Cited by 27
Yu, L., Zhao, J., Tricard, S., Wang, Q., & Fang, J. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.134712 · Cited by 27
Konieczna, L., Kaźmierska, K., Roszkowska, A., Szlagatys‐Sidorkiewicz, A., & Bączek, T. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.03.021 · Cited by 26
Rocchi, S., Caretti, F., Gentili, A., et al. (2016) · Food Chemistry · doi:10.1016/j.foodchem.2016.05.066 · Cited by 26
Selective and sensitive electrochemical device for direct VB2 determination in real products
Kowalczyk, A., Sadowska, M., Krasnodębska‐Ostręga, B., & Nowicka, A. M. (2016) · Talanta · doi:10.1016/j.talanta.2016.10.087 · Cited by 26
Farag, A. S., Pravcová, K., Česlová, L., et al. (2019) · Electroanalysis · doi:10.1002/elan.201800646 · Cited by 26
Khaloo, S. S., Mozaffari, S., Alimohammadi, P., et al. (2016) · International Journal of Food Properties · doi:10.1080/10942912.2015.1130054 · Cited by 25
Gupta, R., Rastogi, P. K., Srivastava, U., et al. (2016) · RSC Advances · doi:10.1039/c6ra12336h · Cited by 25
Safaei, M., Beitollahi, H., & Shishehbore, M. R. (2018) · Russian Journal of Electrochemistry · doi:10.1134/s1023193518130402 · Cited by 25
Liu, T., Cheong, L., Man, Q., Zheng, X. X., Zhang, J., & Song, S. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.04.050 · Cited by 25
Güney, S. (2019) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2019.113518 · Cited by 25
Huang, L., Cao, Y., & Diao, D. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.12.079 · Cited by 24
Self-citationShabangi, M., & Sutton, J. A. (2005) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2004.11.061 · Cited by 23
Byrdwell, W. C., Exler, J., Gebhardt, S. E., et al. (2010) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2010.09.020 · Cited by 23
Zhou, Z., Tan, C., Zheng, Y., & Wang, Q. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.08.032 · Cited by 22
Stanković, D. M., Kuzmanović, D., Mehmeti, E., et al. (2016) · Monatshefte für Chemie - Chemical Monthly · doi:10.1007/s00706-016-1665-2 · Cited by 22
Zhang, H., Gao, Y., & Xiong, H. (2016) · Food Analytical Methods · doi:10.1007/s12161-016-0598-z · Cited by 22
Improving HPLC Analysis of Vitamin A and E: Use of Statistical Experimental Design
Garai, L. (2017) · Procedia Computer Science · doi:10.1016/j.procs.2017.05.177 · Cited by 22
Xu, H., Bai, Z., Wang, G., et al. (2017) · Microchimica Acta · doi:10.1007/s00604-017-2447-1 · Cited by 22
Manivel, P., Madasamy, K., Suryanarayanan, V., et al. (2018) · Journal of the Taiwan Institute of Chemical Engineers · doi:10.1016/j.jtice.2018.10.024 · Cited by 22
Rishi, L., Asgher, M., Yaqoob, M., et al. (2008) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2008.12.024 · Cited by 21
D’Souza, O. J., Mascarenhas, R. J., Satpati, A. K., et al. (2016) · Ionics · doi:10.1007/s11581-016-1806-y · Cited by 21
Smart, A., Westmacott, K., Crew, A. P., et al. (2019) · Biosensors · doi:10.3390/bios9030098 · Cited by 21
Zhang, S., Li, J., Li, L. J., et al. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2019.125531 · Cited by 21
Almeida, M. R., Venâncio, V. P., Aissa, A. F., Darin, J. D. C., Bianchi, M. L. P., & Antunes, L. M. G. (2015) · Food and Chemical Toxicology · doi:10.1016/j.fct.2015.03.015 · Cited by 20
Ramalho, H. M. M., Santos, J., Casal, S., Alves, M. R., & Oliveira, M. B. P. P. (2012) · Journal of Dairy Science · doi:10.3168/jds.2010-3975 · Cited by 20
Michopoulos, A., Florou, A. B., & Prodromidis, M. I. (2015) · Electroanalysis · doi:10.1002/elan.201500061 · Cited by 20
An amperometric microbial biosensor for the determination of vitamin B 12
Ovalle, M., Arroyo, E., Stoytcheva, M., Zlatev, R. K., Enríquez, L. J., & Olivas, A. (2015) · Analytical Methods · doi:10.1039/c5ay01599e · Cited by 20
Motaghedifard, M., Behpour, M., Ghoreishi, S. M., et al. (2016) · Russian Journal of Electrochemistry · doi:10.1134/s1023193516050098 · Cited by 20
Fılık, H., & Avan, A. A. (2017) · Current Analytical Chemistry · doi:10.2174/1573411013666170105143113 · Cited by 20
Vitamin A degradation in triglycerides varying by their saturation levels
Moccand, C., Martin, F., Martiel, I., Gancel, C., Michel, M., Fries, L., & Sagalowicz, L. (2016) · Food Research International · doi:10.1016/j.foodres.2016.06.001 · Cited by 19
Quick and Cost-Effective Estimation of Vitamin C in Multifruit Juices Using Voltammetric Methods
López-Pastor, J. A., Martínez‐Sánchez, A., Aznar-Poveda, J., García-Sánchez, A.-J., Garcı́a-Haro, J., & Aguayo, E. (2020) · Sensors · doi:10.3390/s20030676 · Cited by 19
Wahyuni, W. T., Putra, B. R., & Marken, F. (2020) · The Analyst · doi:10.1039/c9an02186h · Cited by 19
Prasad, B. B., Singh, R., & Singh, K. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.033 · Cited by 18
Jedlińska, K., Strus, M., & Baś, B. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.01.204 · Cited by 18
Singh, R., Jaiswal, S., Singh, K., et al. (2018) · ACS Applied Nano Materials · doi:10.1021/acsanm.8b00902 · Cited by 18
Mena-Bravo, A., Calderón-Santiago, M., de Castro, M. D. L., & Priego‐Capote, F. (2019) · Talanta · doi:10.1016/j.talanta.2019.02.030 · Cited by 18
Simple and Cost‐Effective Electrochemical Approach for Monitoring of Vitamin K in Green Vegetables
Jesadabundit, W., Chaiyo, S., Siangproh, W., et al. (2019) · ChemElectroChem · doi:10.1002/celc.201901432 · Cited by 18
FRET probe for selective and sensitive detection of vitamin A by cadmium free quantum dots (ZnS)
Safari, S., Amiri, A., & Badiei, A. (2020) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2020.118062 · Cited by 18
Maternal vitamin A deficiency during pregnancy affects vascularized islet development
Chien, C.-Y., Lee, M., Cho, C. H.-H., Lin, K., Tosh, D., Wu, R.-R., Mao, W.-Y., & Shen, C. (2016) · The Journal of Nutritional Biochemistry · doi:10.1016/j.jnutbio.2016.07.010 · Cited by 17
Thangphatthanarungruang, J., Ngamaroonchote, A., Laocharoensuk, R., et al. (2018) · Key engineering materials · doi:10.4028/www.scientific.net/kem.777.597 · Cited by 17
Efficacy of two vitamin D immunoassays to detect 25-OH vitamin D2 and D3
Garnett, E. R., Li, J., Rajapakshe, D., et al. (2019) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2019.e00130 · Cited by 17
Quality by design approach for the preparation of fat-soluble vitamins lipid injectable emulsion
Deng, Y., Zhong, G., Wang, Y., Wang, N., Yu, Q., & Yu, X. (2019) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118717 · Cited by 17
Gong, F., Zou, W., Wang, Q., et al. (2019) · Microchemical Journal · doi:10.1016/j.microc.2019.05.057 · Cited by 16
Lu, J., Kou, Y., Xiangmei, J., et al. (2019) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2019.123652 · Cited by 16
Nallbani, A., Holubová, J., Sýs, M., Arbneshi, T., & Vytřas, K. (2018) · Potravinarstvo Slovak Journal of Food Sciences · doi:10.5219/889 · Cited by 15
Electrochemical Determination of Vitamin B12 Based on Cu2+‐Involved Fenton‐like Reaction
Kou, Y., Lu, J., Xiangmei, J., et al. (2019) · Electroanalysis · doi:10.1002/elan.201900019 · Cited by 15
Chekin, F., Mishyn, V., Barras, A., et al. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-01892-1 · Cited by 15
Liu, L., Zhai, J., Zhu, C., Han, L., Ren, W., & Dong, S. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.05.023 · Cited by 14
ZnSe core and ZnSe@ZnS core-shell quantum dots as platform for folic acid sensing
Mir, I. A., Rawat, K., Solanki, P. R., et al. (2017) · Journal of Nanoparticle Research · doi:10.1007/s11051-017-3942-3 · Cited by 14
KAHYA, Ş. E., Cittan, M., & Çelik, A. (2018) · Cumhuriyet Science Journal · doi:10.17776/csj.439630 · Cited by 14
Senthilkumar, E., Shanmugharaj, A. M., Babu, R. S., et al. (2019) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-019-01716-z · Cited by 14
Theoretical Study of Pyridoxine (Vitamin B6) Photolysis
Wu, M., Xu, Q., Strid, Å., et al. (2011) · The Journal of Physical Chemistry A · doi:10.1021/jp205724k · Cited by 13
Fılık, H., Avan, A. A., & Aydar, S. (2016) · Food Analytical Methods · doi:10.1007/s12161-016-0420-y · Cited by 13
Sýs, M., Jashari, G., Švecová, B., et al. (2018) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2018.02.020 · Cited by 13
Garkani, F., Beitollahi, H., Tajik, S., et al. (2019) · Analytical and bioanalytical chemistry research · doi:10.22036/abcr.2018.134444.1212 · Cited by 13
Yao, S., Li, G., Liu, Y., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.07.106 · Cited by 11
Cited by
Sorted by citations
Vitamin C-Sources, Physiological Role, Kinetics, Deficiency, Use, Toxicity, and Determination
Doseděl, M., Jirkovský, E., Macáková, K., Krčmová, L., Javorská, L., Pourová, J., Mercolini, L., Remião, F., Nováková, L., Mladěnka, P., et al. (2021) · Nutrients · doi:10.3390/nu13020615 · Cited by 553
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237
Metadata
- Authors
- Huang, L., Tian, S., Zhao, W., Liu, K., & Guo, J.
- Affiliations
- University of Electronic Science and Technology of China (CN)
- Corresponding author
- Guo, Jinhong
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 222
- Pages
- 121645
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W3089139321
- Cited by
- 108
- References
- 211
- Citations by year
- 2026: 10 · 2025: 16 · 2024: 25 · 2023: 21 · 2022: 19 · 2021: 17
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Talanta (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- electrochemical sensor, vitamin detection, water-soluble vitamins, fat-soluble vitamins, thiamine, riboflavin, vitamin B6, folic acid, vitamin B12, vitamin C, vitamin A, vitamin D, vitamin E, vitamin K, electrochemical oxidation and reduction, food analysis
- MeSH terms
- Ascorbic Acid, Humans, Vitamin D, Vitamin E, Vitamin K, Vitamins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review