Bio-inspired polydopamine layer as a versatile functionalisation protocol for silicon-based photonic biosensors
Open accessAbstract
Photonic biosensors have made major advances in recent years, achieving very high sensitivity, and progressing towards point-of-care deployment. By using photonic resonances, sensors can be label-free, which is particularly attractive for a low-cost technological realisation. A key remaining issue is the biological interface and the efficient and reliable immobilisation of binder molecules such as antibodies; many protocols are currently in use that have led to widely varying sensor performance. Here, we study a very simple and robust surface functionalisation protocol for silicon photonics, which is based on polydopamine, and we demonstrate both its simplicity and its high performance. The use of polydopamine (PDA) is inspired by molluscs, especially mussels, that employ dopamine to adhere to virtually any surface, especially in an aqueous environment. We studied the versatility of the PDA protocol by showing compatibility with 5 different disease biomarkers (Immunoglobulin (IgG), C-reactive protein (CRP), Tumour Necrosis factor-α (TNF-α), Interleukin-6 (IL-6), Matrix metalloproteinase (MMP-9) and show that the protocol is resistant to hydrolysis during incubation; the loss of functionality due to hydrolysis is a major issue for many of the functionalisation protocols commonly used for silicon-based sensors. The study using guided mode resonance-based sensors highlights the wide dynamic range of the protocol (0.01 ng/mL to 1 μg/mL), using IgG, CRP and MMP-9 protein biomarkers as exemplars. In addition, we show that the surface chemistry allows performing measurements in 10% human serum with a sensitivity as low as 10 ng/mL for IgG. We suggest that adopting this protocol will make it easier for researchers to achieve biofunctionalisation and that the biosensor community will be able to achieve more consistent results.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cited by
Sorted by citations
Polydopamine Applications in Biomedicine and Environmental Science
Omidian, H., & Wilson, R. L. (2024) · Materials · doi:10.3390/ma17163916 · Cited by 47 · see citing works
- Authors
- Bakshi, S., Li, K., Dong, P., Barth, I., Kunstmann-Olsen, C., Johnson, S., & Krauss, T. F.
- Affiliations
- University of York (GB)
- Corresponding author
- Bakshi, Shrishty
- Venue
- Talanta
- Publisher
- Elsevier BV
- Published
- 2024-02
- Volume
- 268
- Issue
- Pt 1
- Pages
- 125300
- ISSN
- 0039-9140 (ISSN-L)
- OpenAlex
- W4387457321
- Cited by
- 18
- References
- 0
- Citations by year
- 2026: 2 · 2025: 13 · 2024: 3
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Talanta (publishedVersion, cc-by)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (submittedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, other-oa)
- Funders
- Wellcome Trust (221349/Z/20/Z)
- EPSRC (EP/V047434/1, EP/V047663/1)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Keywords
- polydopamine, silicon photonics, photonic biosensors, guided-mode resonance, antibody immobilization, label-free detection, biomarker detection, IgG, C-reactive protein, TNF-α, interleukin-6, MMP-9, hydrolytic stability, human serum, point-of-care testing
- MeSH terms
- Humans, Immunoglobulin G, Indoles, Polymers, Silicon, Biosensing Techniques, Biomarkers, Matrix Metalloproteinase 9
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›