The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Guidelines for validation of qualitative real-time PCR methods
Open accessAbstract
As for many areas of molecular testing, detection of Genetically Modified Organisms (GMO) relies on the real-time Polymerase Chain Reaction (qPCR) technology. Due to the increasing number of GMO, a screening approach using qualitative screening methods has become an integrated part of GMO detection. However, specific guidelines for the validation of these methods are lacking. Here, a pragmatic approach to conduct in-house and inter-laboratory validation studies for GMO screening methods, is proposed. Such guidelines could be adapted to other areas where qualitative qPCR methods are used for molecular testing allowing to implement easily a more reliable screening phase where necessary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303
Nuclear DNA content of some important plant species
Arumuganathan, K., & Earle, E. D. (1991) · Plant Molecular Biology Reporter · doi:10.1007/bf02672069 · Cited by 3,237
Quality Systems—Medical Devices—Particular Requirements for the Application of ISO 9001
(2004) · GMP/ISO Quality Audit Manual for Healthcare Manufacturers and Their Suppliers, (Volume 2 - Regulations, Standards, and Guidelines) · doi:10.3109/9780203026656-18 · Cited by 2,696
Thompson, M., Ellison, S. L. R., & Wood, R. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274050835 · Cited by 2,478
Product Differentiation by Analysis of DNA Melting Curves during the Polymerase Chain Reaction
Ririe, K. M., Rasmussen, R. P., & Wittwer, C. T. (1997) · Analytical Biochemistry · doi:10.1006/abio.1996.9916 · Cited by 1,654
Taverniers, I., De Loose, M., & Van Bockstaele, E. (2004) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.04.001 · Cited by 944
Self-citationHuggett, J. F., Foy, C. A., Benes, V., Emslie, K., Garson, J. A., Haynes, R., Hellemans, J., Kubista, M., Mueller, R. D., Nolan, T., et al. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.206375 · Cited by 859 · cited 1×
“Similar to the MIQE guidelines that state the minimum information for publication of quantitative real-time PCR and digital PCR experiments (Bustin et al., 2009; Huggett et al., 2013), a template table (Table 4) is provided in which developers of qualitative qPCR methods can find all relevant experimental conditions a…”
MethodStatistical Manual of the Association of Official Analytical Chemists
Steiner, E. H., & Youden, W. J. (1984) · Medical Entomology and Zoology · Cited by 391
ISAAA Briefs brief 41 Global status of Commercialized biotech/GM Crops: 2009
James, C. (2009) · Cited by 323
Quantitative Analysis of Food and Feed Samples with Droplet Digital PCR
Morisset, D., Štebih, D., Milavec, M., Gruden, K., & Žel, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0062583 · Cited by 281
Self-citationTsai, S.-H., & Sheen, L. (1989) · Cited by 203
Marco, M., Cristian, S., Chrystèle, C. D., Broll, H., Andrew, D., Paoletti, C., & Guy, V. D. E. (2008) · Joint Research Centre (European Commission) · doi:10.2788/65827 · Cited by 201
Detecting un-authorized genetically modified organisms (GMOs) and derived materials
Holst‐Jensen, A., Bertheau, Y., Loose, M. D., Grohmann, L., Hamels, S., Hougs, L., Morisset, D., Pecoraro, S., Pla, M., den Bulcke, M. V., et al. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.01.024 · Cited by 160
Self-citationGruère, G. (2007) · IFPRI E-brary (International Food Policy Research Institute) · Cited by 151
GMDD: a database of GMO detection methods
Dong, W., Yang, L., Shen, K., et al. (2008) · BMC Bioinformatics · doi:10.1186/1471-2105-9-260 · Cited by 116
Waiblinger, H., Ernst, B., Anderson, A., et al. (2007) · European Food Research and Technology · doi:10.1007/s00217-007-0748-z · Cited by 102
The global pipeline of new GM crops: implications of asynchronous approval for international trade
Jivraj, S. A., & Rodríguez‐Cerezo, E. (2009) · Joint Research Centre (European Commission) · doi:10.2791/12087 · Cited by 90
Grohmann, L., Brünen‐Nieweler, C., Nemeth, A., et al. (2009) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf901598r · Cited by 79
Self-citationBahrdt, C., Krech, A. B., Wurz, A., et al. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3380-x · Cited by 68
den Bulcke, M. V., Lievens, A., Barbau-Piednoir, E., Mbongolo-Mbella, G., Roosens, N. H. C., Sneyers, M., & Leunda-Casi, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3286-7 · Cited by 67
Self-citationA protocol for the validation of qualitative methods of detection
Macarthur, R., & von Holst, C. (2012) · Analytical Methods · doi:10.1039/c2ay05719k · Cited by 50
Dinon, A. Z., Prins, T. W., van Dijk, J. P., et al. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4875-9 · Cited by 47
Žel, J., Milavec, M., Morisset, D., Damien, P., den Eede, G. V., & Gruden, K. (2011) · Springer eBooks · doi:10.1007/978-1-4614-1390-5 · Cited by 43
Self-citationBarbau-Piednoir, E., Lievens, A., Vandermassen, E., et al. (2011) · European Food Research and Technology · doi:10.1007/s00217-011-1605-7 · Cited by 31
Broeders, S., Barbau-Piednoir, E., Vandermassen, E., et al. (2013) · European Food Research and Technology · doi:10.1007/s00217-013-1910-4 · Cited by 14
Self-citation
Cited by
A Basic Guide to Real Time PCR in Microbial Diagnostics: Definitions, Parameters, and Everything
Kralik, P., & Ricchi, M. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2017.00108 · Cited by 927
Analytical sensitivity and efficiency comparisons of SARS-CoV-2 RT–qPCR primer–probe sets
Vogels, C. B. F., Brito, A. F., Wyllie, A. L., Fauver, J. R., Ott, I. M., Kalinich, C. C., Petrone, M. E., Casanovas-Massana, A., Catherine Muenker, M., Moore, A. J., et al. (2020) · Nature Microbiology · doi:10.1038/s41564-020-0761-6 · Cited by 876
Seed Science and Technology: Biology, Production, Quality
(2023) · Springer eBooks · doi:10.1007/978-981-19-5888-5 · Cited by 875
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Bustin, S., & Nolan, T. (2017) · European Journal of Clinical Investigation · doi:10.1111/eci.12801 · Cited by 113
Metadata
- Authors
- Broeders, S., Huber, I., Grohmann, L., Berben, G., Taverniers, I., Mazzara, M., Roosens, N., & Morisset, D.
- Venue
- Trends in Food Science & Technology
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 37
- Issue
- 2
- Pages
- 115-126
- ISSN
- 0924-2244 (ISSN-L)
- OpenAlex
- W2009016631
- Cited by
- 468
- References
- 25
- FWCI
- 17.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.