CoChat

Navigating the complexity: Managing multivariate error and uncertainties in spectroscopic data modelling

Giussani, Barbara, Gorla, Giulia, Ezenarro, Jokin, Riu, Jordi, Boqué, Ricard · 2024 · TrAC Trends in Analytical Chemistry
Cited by 20

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Spectroscopy and chemometrics , supported by computer science, have yielded promising outcomes, as evidenced by trends observed in literature searches. However, while researchers meticulously construct chemometric models for exploratory, quantitation and classification purposes, the investigation of data quality , particularly error analysis, remains less frequent. Understanding and quantifying measurement errors is crucial for robust spectroscopic modeling and uncertainty estimation. By unraveling complexities related to multivariate errors and uncertainties in spectroscopic data , the scientific community is empowered to extract reliable information from spectroscopic analyses , paving the way for enhanced analytical practices. This review underscores the necessity for the scientific community to integrate error analysis and uncertainty estimation into multivariate analysis methods, offering tailored solutions for diverse data types and analysis objectives.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.trac.2024.118051

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 139

  1. Weber, 2023, Innovative vibrational spectroscopy research for forensic application, Anal. Chem., 95, 167, 10.1021/acs.analchem.2c05094 · DOI
  2. Li, 2024, Vibrational spectroscopy combined with chemometrics in authentication of functional foods, Crit. Rev. Anal. Chem., 54, 333, 10.1080/10408347.2022.2073433 · DOI
  3. Pirutin, 2023, Vibrational spectroscopy as a tool for bioanalytical and biomonitoring studies, Int. J. Mol. Sci., 24, 10.3390/ijms24086947 · DOI
  4. Pandiselvam, 2023, Recent applications of vibrational spectroscopic techniques in the grain industry, Food Rev. Int., 39, 209, 10.1080/87559129.2021.1904253 · DOI
  5. Jansson, 2023, Vibrational spectroscopy and its future applications in microbiology, Appl. Spectrosc. Rev., 58, 132, 10.1080/05704928.2021.1942894 · DOI
  6. Giussani, 2024, Analytical chemistry strategies in the use of miniaturised NIR Instruments: an overview, Crit. Rev. Anal. Chem., 54, 11, 10.1080/10408347.2022.2047607 · DOI
  7. Foli, 2024, Miniaturized Near-Infrared spectrophotometers in forensic analytical science − a critical review, Spectrochim. Acta Mol. Biomol. Spectrosc., 315, 10.1016/j.saa.2024.124297 · doi:10.1016/j.saa.2024.124297
  8. Amirvaresi, 2023, Miniaturized NIR spectroscopy and chemometrics: a smart combination to solve food authentication challenges, Front. Anal. Sci., 3, 1, 10.3389/frans.2023.1118590 · DOI
  9. Lorber, 1988, Estimation of prediction error for multivariate calibration, J. Chemom., 2, 93, 10.1002/cem.1180020203 · DOI
  10. Wentzell, 2014, Measurement errors in multivariate chemical data, J. Braz. Chem. Soc., 25, 183
  11. Reis, 2005, Integration of data uncertainty in linear regression and process optimization, AIChE J., 51, 3007, 10.1002/aic.10540 · doi:10.1002/aic.10540
  12. Reis, 2004, A comparative study of linear regression methods in noisy environments, J. Chemom., 18, 526, 10.1002/cem.897 · doi:10.1002/cem.897
  13. Feital, 2014, Comparison of methods for estimation of the covariance matrix of measurement errors, Can. J. Chem. Eng., 92, 2228, 10.1002/cjce.22063 · doi:10.1002/cjce.22063
  14. Gorla, 2022, Unravelling error sources in miniaturized NIR spectroscopic measurements: the case study of forages, Anal. Chim. Acta, 1211, 10.1016/j.aca.2022.339900 · doi:10.1016/j.aca.2022.339900
  15. Pulido, 2003, Uncertainty of results in routine qualitative analysis, TrAC, Trends Anal. Chem., 22, 647, 10.1016/S0165-9936(03)01104-X · DOI
  16. Allegrini, 2017, Recent advances in analytical figures of merit: heteroscedasticity strikes back, Anal. Methods, 9, 739, 10.1039/C6AY02916G · doi:10.1039/c6ay02916g
  17. Allegrini, 2014, IUPAC-consistent approach to the limit of detection in partial least-squares calibration, Anal. Chem., 86, 7858, 10.1021/ac501786u · DOI
  18. Allegrini, 2016, Multi-way figures of merit in the presence of heteroscedastic and correlated instrumental noise: unfolded partial least-squares with residual multi-linearization, Chemometr. Intell. Lab. Syst., 158, 200, 10.1016/j.chemolab.2016.09.001 · doi:10.1016/j.chemolab.2016.09.001
  19. Akvan, 2023, A systematic study on the effect of different error structures on pseudo-univariate and multivariate figures of merit, J. Chemom., 37, 1, 10.1002/cem.3410 · doi:10.1002/cem.3410
  20. Fragoso, 2016, A new and consistent parameter for measuring the quality of multivariate analytical methods: generalized analytical sensitivity, Anal. Chim. Acta, 933, 43, 10.1016/j.aca.2016.06.022 · doi:10.1016/j.aca.2016.06.022
  21. Allegrini, 2016, Sensitivity, prediction uncertainty, and detection limit for artificial neural network calibrations, Anal. Chem., 88, 7807, 10.1021/acs.analchem.6b01857 · doi:10.1021/acs.analchem.6b01857
  22. Reis, 2015, Challenges in the specification and integration of measurement uncertainty in the development of data-driven models for the chemical processing industry, Ind. Eng. Chem. Res., 54, 9159, 10.1021/ie504577d · DOI
  23. Zhou, 2020, Prediction and uncertainty propagation for completion time of batch processes based on data-driven modeling, Ind. Eng. Chem. Res., 59, 14374, 10.1021/acs.iecr.0c01236 · DOI
  24. Bano, 2017, Uncertainty back-propagation in PLS model inversion for design space determination in pharmaceutical product development, Comput. Chem. Eng., 101, 110, 10.1016/j.compchemeng.2017.02.038 · DOI
  25. Preisner, 2008, Uncertainty assessment in FT-IR spectroscopy based bacteria classification models, Chemometr. Intell. Lab. Syst., 94, 33, 10.1016/j.chemolab.2008.06.005 · DOI
  26. Du, 2018, Error propagation of partial least squares for parameters optimization in NIR modeling, Spectrochim. Acta Mol. Biomol. Spectrosc., 192, 244, 10.1016/j.saa.2017.10.069 · doi:10.1016/j.saa.2017.10.069
  27. Heid, 2023, Characterizing uncertainty in machine learning for chemistry, J. Chem. Inf. Model., 63, 4012, 10.1021/acs.jcim.3c00373 · DOI
  28. Olivieri, 2002, A simple approach to uncertainty propagation in preprocessed multivariate calibration, J. Chemom., 16, 207, 10.1002/cem.716 · doi:10.1002/cem.716
  29. Allegrini, 2016, Generalized error-dependent prediction uncertainty in multivariate calibration, Anal. Chim. Acta, 903, 51, 10.1016/j.aca.2015.11.028 · doi:10.1016/j.aca.2015.11.028
  30. Bu, 2013, A discussion on the use of prediction uncertainty estimation of NIR data in partial least squares for quantitative pharmaceutical tablet assay methods, Chemometr. Intell. Lab. Syst., 120, 84, 10.1016/j.chemolab.2012.11.005 · DOI
  31. De Bièvre, 1997, Measurement results without statements of reliability (uncertainty) should not be taken seriously, Accred Qual. Assur., 2, 269, 10.1007/s007690050147 · doi:10.1007/s007690050147
  32. Reis, 2006, Heteroscedastic latent variable modelling with applications to multivariate statistical process control, Chemometr. Intell. Lab. Syst., 80, 57, 10.1016/j.chemolab.2005.07.002 · DOI
  33. Wentzell, 2012, Exploratory data analysis with noisy measurements, J. Chemom., 26, 264, 10.1002/cem.2428 · DOI
  34. Allegrini, 2018, Error Covariance Penalized Regression: a novel multivariate model combining penalized regression with multivariate error structure, Anal. Chim. Acta, 1011, 20, 10.1016/j.aca.2018.02.002 · doi:10.1016/j.aca.2018.02.002
  35. Schoot, 2022, Predicting the performance of handheld near-infrared photonic sensors from a master benchtop device, Anal. Chim. Acta, 1203, 10.1016/j.aca.2022.339707 · doi:10.1016/j.aca.2022.339707
  36. Andrews, 1997, Applications of maximum likelihood principal component analysis: incomplete data sets and calibration transfer, Anal. Chim. Acta, 350, 341, 10.1016/S0003-2670(97)00270-5 · DOI
  37. Monteiro, 2017, Statistical aspects of near-infrared spectroscopy for the characterization of errors and model building, Appl. Spectrosc., 71, 1665, 10.1177/0003702817704587 · doi:10.1177/0003702817704587
  38. Mohammad Jafari, 2021, Balanced scaling as a pretreatment step in Multivariate Curve Resolution analysis of noisy data, Microchem. J., 160, 10.1016/j.microc.2020.105738 · doi:10.1016/j.microc.2020.105738
  39. Blanchet, 2009, Chemometrics description of measurement error structure: study of an ultrafast absorption spectroscopy experiment, Anal. Chim. Acta, 642, 19, 10.1016/j.aca.2008.11.039 · doi:10.1016/j.aca.2008.11.039
  40. Schreyer, 2002, Application of maximum likelihood principal components regression to fluorescence emission spectra, Appl. Spectrosc., 56, 789, 10.1366/000370202760076857 · doi:10.1366/000370202760076857
  41. Andersen, 2004, Quantification and handling of sampling errors in instrumental measurements: a case study, Chemometr. Intell. Lab. Syst., 72, 43, 10.1016/j.chemolab.2003.12.014 · doi:10.1016/j.chemolab.2003.12.014
  42. Leger, 2005, Methods for systematic investigation of measurement error covariance matrices, Chemometr. Intell. Lab. Syst., 77, 181, 10.1016/j.chemolab.2004.09.017 · doi:10.1016/j.chemolab.2004.09.017
  43. Wentzell, 2017, Improved modeling of multivariate measurement errors based on the Wishart distribution, Anal. Chim. Acta, 959, 1, 10.1016/j.aca.2016.12.009 · DOI
  44. Olivieri, 2006, Uncertainty estimation and figures of merit for multivariate calibration: (IUPAC technical report), Pure Appl. Chem., 78, 633, 10.1351/pac200678030633 · DOI
  45. Booksh, 1994, Theory of analytical chemistry, Anal. Chem., 66, 782, 10.1021/ac00087a718 · doi:10.1021/ac00087a718
  46. Wentzell, 2015, The errors of my ways: maximum likelihood PCA seventeen years after bruce, ACS (Am. Chem. Soc.) Symp. Ser., 1199, 31
  47. Galbán, 2007, Uncertainty in modern spectrophotometers, Anal. Chem., 79, 4763, 10.1021/ac071933h · doi:10.1021/ac071933h
  48. Ingle, 1972, Evaluation of precision of quantitative molecular absorption spectrometric measurements, Anal. Chem., 44, 1375, 10.1021/ac60316a010 · doi:10.1021/ac60316a010
  49. Rothman, 1975, Theoretical and experimental investigation of factors affecting precision in molecular absorption spectrophotometry, Anal. Chem., 47, 1226, 10.1021/ac60358a029 · doi:10.1021/ac60358a029
  50. Beć, 2021, Principles and applications of miniaturized near-infrared (NIR) spectrometers, Chem. Eur J., 27, 1514, 10.1002/chem.202002838 · DOI · Paper page
  51. Kirchler, 2017, Critical evaluation of spectral information of benchtop vs. portable near-infrared spectrometers: quantum chemistry and two-dimensional correlation spectroscopy for a better understanding of PLS regression models of the rosmarinic acid content in Rosmarin, Analyst, 142, 455, 10.1039/C6AN02439D · DOI
  52. Mayr, 2021, Near-infrared spectroscopy in quality control of Piper nigrum: a comparison of performance of benchtop and handheld spectrometers, Talanta, 223, 10.1016/j.talanta.2020.121809 · DOI
  53. Sanchez, 1990, Tensorial resolution: a direct trilinear decomposition, J. Chemom., 4, 29, 10.1002/cem.1180040105 · doi:10.1002/cem.1180040105
  54. Olivieri, 2015, Figures of merit in multiway calibration, 541, 10.1016/B978-0-444-63527-3.00013-8 · doi:10.1016/b978-0-444-63527-3.00013-8
  55. Martens, 2003, Pre-whitening of data by covariance-weighted pre-processing, J. Chemom., 17, 153, 10.1002/cem.780 · DOI
  56. Bland, 1999, Measuring agreement in method comparison studies, Stat. Methods Med. Res., 8, 135, 10.1177/096228029900800204 · DOI · Paper page
  57. Francq, 2014, Measurement methods comparison with errors-in-variables regressions. From horizontal to vertical OLS regression, review and new perspectives, Chemometr. Intell. Lab. Syst., 134, 123, 10.1016/j.chemolab.2014.03.006 · DOI
  58. Hartmann, 1997, Detection of bias in method comparison by regression analysis, Anal. Chim. Acta, 338, 19, 10.1016/S0003-2670(96)00341-8 · doi:10.1016/s0003-2670(96)00341-8
  59. Esbensen, 2014, Theory of sampling (TOS) versus measurement uncertainty (MU) - a call for integration, TrAC, Trends Anal. Chem., 57, 93, 10.1016/j.trac.2014.02.007 · doi:10.1016/j.trac.2014.02.007
  60. Belter, 2014, Over a century of detection and quantification capabilities in analytical chemistry - historical overview and trends, Talanta, 129, 606, 10.1016/j.talanta.2014.05.018 · doi:10.1016/j.talanta.2014.05.018
  61. Wentzell, 2014, Characterization of heteroscedastic measurement noise in the absence of replicates, Anal. Chim. Acta, 847, 16, 10.1016/j.aca.2014.08.007 · doi:10.1016/j.aca.2014.08.007
  62. Driscoll, 2019, NoiseGen - analytical measurement error simulation software, Chemometr. Intell. Lab. Syst., 189, 155, 10.1016/j.chemolab.2019.04.011 · doi:10.1016/j.chemolab.2019.04.011
  63. Gorla, 2023, A multivariate analysis-driven workflow to tackle uncertainties in miniaturized NIR data, Molecules, 28, 10.3390/molecules28247999 · doi:10.3390/molecules28247999
  64. Matinrad, 2020, Systematic investigation of the measurement error structure in a smartphone-based spectrophotometer, Anal. Chim. Acta, 1129, 98, 10.1016/j.aca.2020.06.066 · doi:10.1016/j.aca.2020.06.066
  65. Todeschini, 1999, The K correlation index: theory development and its application in chemometrics, Chemometr. Intell. Lab. Syst., 46, 13, 10.1016/S0169-7439(98)00124-5 · DOI · Paper page
  66. Meza Ramirez, 2021, Applications of machine learning in spectroscopy, Appl. Spectrosc. Rev., 56, 733, 10.1080/05704928.2020.1859525 · DOI · Paper page
  67. Castura, 2022, Discriminability and uncertainty in principal component analysis (PCA) of temporal check-all-that-apply (TCATA) data, Food Qual. Prefer., 96, 10.1016/j.foodqual.2021.104370 · doi:10.1016/j.foodqual.2021.104370
  68. Wehrens, 2000, The bootstrap: a tutorial, Chemometr. Intell. Lab. Syst., 54, 35, 10.1016/S0169-7439(00)00102-7 · DOI · Paper page
  69. Wu, 1986, Jackknife, bootstrap and other resampling methods in regression analysis, Ann. Stat., 14, 1261
  70. Josse, 2016, Confidence areas for fixed-effects PCA, J. Comput. Graph Stat., 25, 28, 10.1080/10618600.2014.950871 · doi:10.1080/10618600.2014.950871
  71. Beleites, 2008, Assessing and improving the stability of chemometric models in small sample size situations, Anal. Bioanal. Chem., 390, 1261, 10.1007/s00216-007-1818-6 · DOI
  72. Lin, 2016, Fisher optimal subspace shrinkage for block variable selection with applications to NIR spectroscopic analysis, Chemometr. Intell. Lab. Syst., 159, 196, 10.1016/j.chemolab.2016.11.002 · DOI
  73. Field, 2007, Bootstrapping clustered data, J R Stat Soc Series B Stat Methodol, 69, 369, 10.1111/j.1467-9868.2007.00593.x · DOI · Paper page
  74. Beleites, 2005, Variance reduction in estimating classification error using sparse datasets, Chemometr. Intell. Lab. Syst., 79, 91, 10.1016/j.chemolab.2005.04.008 · DOI
  75. Groff, 2022, Uncertainty estimation strategies for quantitative non-targeted analysis, Anal. Bioanal. Chem., 414, 4919, 10.1007/s00216-022-04118-z · DOI
  76. MacKinnon, 2023, Fast and reliable jackknife and bootstrap methods for cluster‐robust inference, J. Appl. Econom., 38, 671, 10.1002/jae.2969 · DOI
  77. Fang, 2023, Evaluating and implementing block jackknife resampling Mendelian randomization to mitigate bias induced by overlapping samples, Hum. Mol. Genet., 32, 192, 10.1093/hmg/ddac186 · DOI
  78. Jaumot, 2010, MCR-BANDS: a user friendly MATLAB program for the evaluation of rotation ambiguities in Multivariate Curve Resolution, Chemometr. Intell. Lab. Syst., 103, 96, 10.1016/j.chemolab.2010.05.020 · DOI
  79. Golshan, 2016, A review of recent methods for the determination of ranges of feasible solutions resulting from soft modelling analyses of multivariate data, Anal. Chim. Acta, 911, 1, 10.1016/j.aca.2016.01.011 · doi:10.1016/j.aca.2016.01.011
  80. Dadashi, 2017, Error propagation along the different regions of multivariate curve resolution feasible solutions, Chemometr. Intell. Lab. Syst., 162, 203, 10.1016/j.chemolab.2017.01.009 · doi:10.1016/j.chemolab.2017.01.009
  81. Esbensen, 2010, Principles of proper validation: use and abuse of re-sampling for validation, J. Chemom., 24, 168, 10.1002/cem.1310 · DOI · Paper page
  82. Lopez, 2023, The importance of choosing a proper validation strategy in predictive models. A tutorial with real examples, Anal. Chim. Acta, 1275, 10.1016/j.aca.2023.341532 · DOI
  83. Westad, 2015, Validation of chemometric models - a tutorial, Anal. Chim. Acta, 893, 14, 10.1016/j.aca.2015.06.056 · DOI · Paper page
  84. Olivieri, 2014, Analytical figures of merit: from univariate to multiway calibration, Chem. Rev., 114, 5358, 10.1021/cr400455s · DOI · Paper page
  85. Bauer, 1992, Selectivity and limits of detection in inductively coupled plasma optical emission spectrometry using multivariate calibration, Spectrochim. Acta Part B At. Spectrosc., 47, 179, 10.1016/0584-8547(92)80017-B · doi:10.1016/0584-8547(92)80017-b
  86. De Vries, 1995, Prediction error in partial least squares regression: a critique on the deviation used in the Unscrambler, Chemometr. Intell. Lab. Syst., 30, 239, 10.1016/0169-7439(95)00030-5 · DOI
  87. Faber, 1996, Prediction error in least squares regression: further critique on the deviation used in the Unscrambler, Chemometr. Intell. Lab. Syst., 34, 283, 10.1016/0169-7439(96)00022-6 · DOI
  88. Høy, 1998, Review of partial least squares regression prediction error in Unscrambler, Chemometr. Intell. Lab. Syst., 44, 123, 10.1016/S0169-7439(98)00163-4 · DOI
  89. Karstang, 1992, Estimation of prediction error for samples within the calibration range, J. Chemom., 6, 177, 10.1002/cem.1180060403 · doi:10.1002/cem.1180060403
  90. Faber, 1997, Propagation of measurement errors for the validation of predictions obtained by principal component regression and partial least squares, J. Chemom., 11, 181, 10.1002/(SICI)1099-128X(199705)11:3<181::AID-CEM459>3.0.CO;2-7 · DOI · Paper page
  91. Faber, 1998, Characterizing the uncertainty in near-infrared spectroscopic prediction of mixed-oxygenate concentrations in gasoline: sample-specific prediction intervals, Anal. Chem., 70, 4877, 10.1021/ac9815608 · DOI
  92. Boqué, 1999, Multivariate detection limits with fixed probabilities of error, Chemometr. Intell. Lab. Syst., 45, 397, 10.1016/S0169-7439(98)00195-6 · DOI
  93. Faber, 2003, Sample-specific standard error of prediction for partial least squares regression, TrAC, Trends Anal. Chem., 22, 330, 10.1016/S0165-9936(03)00503-X · DOI
  94. Faber, 2002, Standard error of prediction for multiway PLS 1. Background and a simulation study, Chemometr. Intell. Lab. Syst., 61, 133, 10.1016/S0169-7439(01)00204-0 · DOI
  95. Skou, 2017, Monitoring process water quality using near infrared spectroscopy and partial least squares regression with prediction uncertainty estimation, Appl. Spectrosc., 71, 410, 10.1177/0003702816654165 · DOI
  96. Otto, 1986, Selectivity in multicomponent analysis, Anal. Chim. Acta, 180, 445, 10.1016/0003-2670(86)80024-1 · doi:10.1016/0003-2670(86)80024-1
  97. Olivieri, 2015, Practical guidelines for reporting results in single- and multi-component analytical calibration: a tutorial, Anal. Chim. Acta, 868, 10, 10.1016/j.aca.2015.01.017 · DOI · Paper page
  98. Boqué, 1997, Computing detection limits in multicomponent spectroscopic analysis, TrAC, Trends Anal. Chem., 16, 432, 10.1016/S0165-9936(97)00048-4 · doi:10.1016/s0165-9936(97)00048-4
  99. Boqué, 1996, Multivariate detection limits estimators, Chemometr. Intell. Lab. Syst., 32, 11, 10.1016/0169-7439(95)00049-6 · doi:10.1016/0169-7439(95)00049-6
  100. Lorber, 1986, Error propagation and figures of merit for quantification by solving matrix equations, Anal. Chem., 58, 1167, 10.1021/ac00297a042 · DOI · Paper page
  101. Boqué, 2000, Detection limits in classical multivariate calibration models, Anal. Chim. Acta, 423, 41, 10.1016/S0003-2670(00)01101-6 · DOI
  102. Wu, 2013, Multivariate detection limits of on-line NIR model for extraction process of chlorogenic acid from Lonicera japonica, J. Pharm. Biomed. Anal., 77, 16, 10.1016/j.jpba.2012.12.026 · DOI
  103. Alcalà, 2008, Analysis of low content drug tablets by transmission near infrared spectroscopy: selection of calibration ranges according to multivariate detection and quantitation limits of PLS models, J. Pharmaceut. Sci., 97, 5318, 10.1002/jps.21373 · doi:10.1002/jps.21373
  104. Stine, 1985, Bootstrap prediction intervals for regression, J. Am. Stat. Assoc., 80, 1026, 10.1080/01621459.1985.10478220 · DOI · Paper page
  105. Denham, 1997, Prediction intervals in partial least squares, J. Chemom., 11, 39, 10.1002/(SICI)1099-128X(199701)11:1<39::AID-CEM433>3.0.CO;2-S · DOI · Paper page
  106. Butler, 1980, Predictive intervals based on reuse of the sample, J. Am. Stat. Assoc., 75, 881, 10.1080/01621459.1980.10477567 · DOI
  107. Carroll, 1991, Prediction and tolerance intervals with transformation and/or weighting, Technometrics, 33, 197, 10.1080/00401706.1991.10484807 · DOI
  108. Phatak, 1993, An approach to interval estimation in partial least squares regression, Anal. Chim. Acta, 277, 495, 10.1016/0003-2670(93)80461-S · DOI
  109. Serneels, 2004, Calculation of PLS prediction intervals using efficient recursive relations for the Jacobian matrix, J. Chemom., 18, 76, 10.1002/cem.849 · DOI
  110. Faber, 2002, Uncertainty estimation for multivariate regression coefficients, Chemometr. Intell. Lab. Syst., 64, 169, 10.1016/S0169-7439(02)00102-8 · DOI
  111. Marini, 2010, Classification methods in chemometrics, Curr. Anal. Chem., 6, 72, 10.2174/157341110790069592 · DOI
  112. Cuadros-Rodríguez, 2016, Quality performance metrics in multivariate classification methods for qualitative analysis, TrAC, Trends Anal. Chem., 80, 612, 10.1016/j.trac.2016.04.021 · DOI
  113. Pérez, 2009, Calculation of the reliability of classification in discriminant partial least-squares binary classification, Chemometr. Intell. Lab. Syst., 95, 122, 10.1016/j.chemolab.2008.09.005 · doi:10.1016/j.chemolab.2008.09.005
  114. Botella, 2009, Classification from microarray data using probabilistic discriminant partial least squares with reject option, Talanta, 80, 321, 10.1016/j.talanta.2009.06.072 · DOI
  115. Pérez, 2010, Multi-class classification with probabilistic discriminant partial least squares (p-DPLS), Anal. Chim. Acta, 664, 27, 10.1016/j.aca.2010.01.059 · DOI
  116. Fearn, 2019, Classifying with confidence using Bayes rule and kernel density estimation, Chemometr. Intell. Lab. Syst., 189, 81, 10.1016/j.chemolab.2019.04.004 · DOI
  117. Pérez-Marín, 2021, Probabilistic classification models for the in situ authentication of iberian pig carcasses using near infrared spectroscopy, Talanta, 222, 10.1016/j.talanta.2020.121511 · doi:10.1016/j.talanta.2020.121511
  118. Toher, 2007, A comparison of model-based and regression classification techniques applied to near infrared spectroscopic data in food authentication studies, Chemometr. Intell. Lab. Syst., 89, 102, 10.1016/j.chemolab.2007.06.005 · DOI
  119. van der Voet, 1984, The improvement of SIMCA classification by using kernel density estimation, Anal. Chim. Acta, 161, 115, 10.1016/S0003-2670(00)85783-9 · doi:10.1016/s0003-2670(00)85783-9
  120. Vitale, 2023, Class modelling by soft independent modelling of class analogy: why, when, how? A tutorial, Anal. Chim. Acta, 1270, 10.1016/j.aca.2023.341304 · DOI
  121. Beleites, 2013, Sample size planning for classification models, Anal. Chim. Acta, 760, 25, 10.1016/j.aca.2012.11.007 · DOI · Paper page
  122. de Almeida, 2013, Discrimination between authentic and counterfeit banknotes using Raman spectroscopy and PLS-DA with uncertainty estimation, Microchem. J., 109, 170, 10.1016/j.microc.2012.03.006 · DOI
  123. Rocha, 2016, Classification of biodegradable materials using QSAR modelling with uncertainty estimation, SAR QSAR Environ. Res., 27, 799, 10.1080/1062936X.2016.1238010 · DOI
  124. Rocha, 2018, Classification of samples from NMR-based metabolomics using principal components analysis and partial least squares with uncertainty estimation, Anal. Bioanal. Chem., 410, 6305, 10.1007/s00216-018-1240-2 · DOI
  125. Morais, 2019, Uncertainty estimation and misclassification probability for classification models based on discriminant analysis and support vector machines, Anal. Chim. Acta, 1063, 40, 10.1016/j.aca.2018.09.022 · DOI
  126. Villa, 2008, Calculation of the probability of correct classification in probabilistic bagged k-Nearest Neighbours, Chemometr. Intell. Lab. Syst., 94, 51, 10.1016/j.chemolab.2008.06.007 · doi:10.1016/j.chemolab.2008.06.007
  127. Paatero, 1993, Analysis of different modes of factor analysis as least squares fit problems, Chemometr. Intell. Lab. Syst., 18, 183, 10.1016/0169-7439(93)80055-M · doi:10.1016/0169-7439(93)80055-m
  128. Kowalski, 1976, Improving the reliability of factor analysis of chemical data by utilizing the measured analytical uncertainty, Anal. Chem., 48, 1986
  129. Schuermans, 2005, On the equivalence between total least squares and maximum likelihood PCA, Anal. Chim. Acta, 544, 254, 10.1016/j.aca.2004.12.059 · DOI
  130. Wentzell, 2018, Implications of measurement error structure on the visualization of multivariate chemical data: hazards and alternatives, Can. J. Chem., 96, 738, 10.1139/cjc-2017-0730 · DOI
  131. Kompany-Zareh, 2023, Factor analysis for signal modeling and noise characterization in spectro-kinetic data, Chemometr. Intell. Lab. Syst., 240, 10.1016/j.chemolab.2023.104916 · DOI
  132. Wentzell, 2021, Beyond principal components: a critical comparison of factor analysis methods for subspace modelling in chemistry, Anal. Methods, 13, 4188, 10.1039/D1AY01124C · DOI
  133. Wentzell, 1997, Maximum likelihood multivariate calibration, Anal. Chem., 69, 2299, 10.1021/ac961029h · doi:10.1021/ac961029h
  134. Kourti, 1995, Process analysis, monitoring and diagnosis, using multivariate projection methods, Chemometr. Intell. Lab. Syst., 28, 3, 10.1016/0169-7439(95)80036-9 · doi:10.1016/0169-7439(95)80036-9 · Paper page
  135. Vega-Montoto, 2003, Maximum likelihood parallel factor analysis (MLPARAFAC), J. Chemom., 17, 237, 10.1002/cem.789 · doi:10.1002/cem.789
  136. Bro, 2002, Maximum likelihood fitting using ordinary least squares algorithms, J. Chemom., 16, 387, 10.1002/cem.734 · DOI
  137. Chen, 2007, Toward Bayesian chemometrics-A tutorial on some recent advances, Anal. Chim. Acta, 602, 1, 10.1016/j.aca.2007.08.044 · DOI
  138. Armstrong, 2009, An introduction to Bayesian methods for analyzing chemistry data. Part 1: an introduction to Bayesian theory and methods, Chemometr. Intell. Lab. Syst., 97, 194, 10.1016/j.chemolab.2009.04.001 · DOI
  139. Hibbert, 2009, An introduction to Bayesian methods for analyzing chemistry data. Part II: a review of applications of Bayesian methods in chemistry, Chemometr. Intell. Lab. Syst., 97, 211, 10.1016/j.chemolab.2009.03.009 · DOI

Metadata

Authors
Giussani, B., Gorla, G., Ezenarro, J., Riu, J., & Boqué, R.
Venue
TrAC Trends in Analytical Chemistry
Publisher
Elsevier BV
Published
2024-12
Volume
181
Pages
118051
ISSN
0165-9936
Cited by
20
References
2
Language
en
Licence
Funders
  • European Regional Development Fund
  • Departament d'Universitats, Recerca i Societat de la Informació
  • Banco Santander
  • Ministerio de Ciencia e Innovación
  • University of the Basque Country
  • State Agency of Research
  • Rovira i Virgili University

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Navigating the complexity: Managing multivariate error and uncertainties in spectroscopic data modelling. https://app.cochat.ai/papers/10.1016/j.trac.2024.118051
The paper
Giussani, B., Gorla, G., Ezenarro, J., Riu, J., & Boqué, R. (2024). Navigating the complexity: Managing multivariate error and uncertainties in spectroscopic data modelling. TrAC Trends in Analytical Chemistry. https://doi.org/10.1016/j.trac.2024.118051

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.