Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Objective To evaluate reliability in 3D landmark identification using Cone-Beam CT. Study Design Twelve pre-surgery CBCTs were randomly selected from 159 orthognathic surgery patients. Three observers independently repeated three times the identification of 30 landmarks in the sagittal, coronal, and axial slices. A mixed effects ANOVA model estimated the Intraclass Correlations (ICC) and assessed systematic bias. Results The ICC was >0.9 for 86% of intra-observer assessments and 66% of inter-observer assessments. Only 1% of intra-observer and 3% of inter-observer coefficients were <0.45. The systematic difference among observers was greater in X and Z than in Y dimensions, but the maximum mean difference was quite small. Conclusion Overall, the intra- and inter-observer reliability was excellent. 3D landmark identification using CBCT can offer consistent and reproducible data, if a protocol for operator training and calibration is followed. This is particularly important for landmarks not easily specified in all three planes of space.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applied Linear Statistical Models
Ziegel, E. R., Neter, J., Wasserman, W., & Kutner, M. (1992) · Technometrics · doi:10.2307/1269588 · Cited by 9,907
Applied Linear Statistical Models
(1997) · Technometrics · doi:10.1080/00401706.1997.10485141 · Cited by 7,185
Morphometric Tools for Landmark Data: Geometry and Biology
Bookstein, F. L. (1992) · Cambridge University Press eBooks · doi:10.1017/cbo9780511573064 · Cited by 4,365
Applied Linear Statistical Models.
Barnett, V., Neter, J., & Wasserman, W. (1975) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2984653 · Cited by 2,286
Clinical applications of cone-beam computed tomography in dental practice.
Scarfe, W. C., Farman, A. G., & Sukovic, P. (2006) · PubMed · Cited by 1,528
Morphometric Tools for Landmark Data.
Bookstein, F. (1998) · Biometrics · doi:10.2307/2534038 · Cited by 1,378
The reliability of head film measurements
Baumrind, S., & Frantz, R. C. (1971) · American Journal of Orthodontics · doi:10.1016/0002-9416(71)90028-5 · Cited by 879
Lascala, C., Panella, J., & Marques, M. (2004) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/25500850 · Cited by 564
Ludlow, J., Davies-Ludlow, L., & Brooks, S. (2003) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/26310390 · Cited by 463
Superimposition of 3D cone-beam CT models of orthognathic surgery patients
Cevidanes, L., Bailey, L., Tucker, G., Styner, M., Mol, A., Phillips, C., Proffit, W., & Turvey, T. (2005) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/17102411 · Cited by 373
Self-citationImage analysis and superimposition of 3-dimensional cone-beam computed tomography models
Cevidanes, L. H. S., Styner, M. A., & Proffit, W. R. (2006) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.12.008 · Cited by 358 · cited 1×
“renderings displayed by commercial softwares such as Dolphin and Invivo (Anatomage, San Jose, CA)) for assessment of treatment changes.(6,15,23-25) However, 3D surface models are not available for routine clinical use, because these methods are more time consuming and require computing expertise.”
Self-citationRadiation absorbed in maxillofacial imaging with a new dental computed tomography device
Mah, J. K., Danforth, R. A., Bumann, A., & Hatcher, D. (2003) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/s1079-2104(03)00350-0 · Cited by 345
Hashimoto, K., Arai, Y., Iwai, K., Araki, M., Kawashima, S., & Terakado, M. (2003) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1067/moe.2003.120 · Cited by 308
Cevidanes, L. H. S., Bailey, L. J., Tucker, S. F., Styner, M. A., Mol, A., Phillips, C. L., Proffit, W. R., & Turvey, T. (2007) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.03.029 · Cited by 212 · cited 1×
“renderings displayed by commercial softwares such as Dolphin and Invivo (Anatomage, San Jose, CA)) for assessment of treatment changes.(6,15,23-25) However, 3D surface models are not available for routine clinical use, because these methods are more time consuming and require computing expertise.”
Self-citationA New Method of 3-D Cephalometry Part I: The Anatomic Cartesian 3-D Reference System
Swennen, G. R. J., Schutyser, F., Barth, E.-L., De Groeve, P., & De Mey, A. (2006) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200603000-00019 · Cited by 193
From 2-dimensional cephalograms to 3-dimensional computed tomography scans
Halazonetis, D. J. (2005) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.01.004 · Cited by 183 · cited 2×
“Just as numerous 2D cephalometric analyses have been proposed since the introduction of the cephalostat by Broadbent, it appears likely that 3D cephalometry will also lead to new definitions of landmarks and new proposed analyses.(2) However, 3D cephalometry requires alterations in paradigms of the 2D radiographic and…”
3-D Volume Imaging for Dentistry: A New Dimension
Danforth, R. A., Dus, I., & Mah, J. K. (2003) · Journal of the California Dental Association · doi:10.1080/19424396.2003.12224264 · Cited by 163 · cited 1×
“cost.(3,4,28,30) The use of 3D medical CT cephalometric analysis might be limited to those complex orthognathic cases with asymmetry and operable craniofacial syndromes.”
Lou, L., Lagravère, M. O., Compton, S. M., Major, P. W., & Flores‐Mir, C. (2006) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2006.07.015 · Cited by 147 · cited 5×
“cost.(3,4,28,30) The use of 3D medical CT cephalometric analysis might be limited to those complex orthognathic cases with asymmetry and operable craniofacial syndromes.”
Influential
Cited by
Lenza, M., Lenza, M. D. O., Dalstra, M., Melsen, B., & Cattaneo, P. (2010) · Orthodontics & Craniofacial Research · doi:10.1111/j.1601-6343.2010.01482.x · Cited by 264
Wang, C.-W., Huang, C.-T., Hsieh, M.-C., Li, C.-H., Chang, S.-W., Li, W.-C., Vandaele, R., Maree, R., Jodogne, S., Geurts, P., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2412951 · Cited by 235
“studies focused on landmark identification problems [9]–[11].”
Patcas, R., Müller, L., Ullrich, O., & Peltomäki, T. (2012) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2011.06.034 · Cited by 206
Working with DICOM craniofacial images
Grauer, D., Cevidanes, L. S. H., & Proffit, W. R. (2009) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2009.04.016 · Cited by 189
Self-citationZreaqat, M., Hassan, R., Samsudin, A. R., & Alforaidi, S. (2023) · European Journal of Pediatrics · doi:10.1007/s00431-023-05226-3 · Cited by 33
Metadata
- Authors
- de Oliveira, A. E. F., Cevidanes, L. H. S., Phillips, C., Motta, A., Burke, B., & Tyndall, D.
- Venue
- Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 107
- Issue
- 2
- Pages
- 256-265
- ISSN
- 1079-2104 (ISSN-L)
- OpenAlex
- W2031555939
- Cited by
- 209
- References
- 18
- FWCI
- 12.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.