Implantable biosensors and their contribution to the future of precision medicine
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Precision medicine can be defined as the prevention, investigation and treatment of diseases taking individual variability into account. There are multiple ways in which the field of precision medicine may be advanced; however, recent innovations in the fields of electronics and microfabrication techniques have led to an increased interest in the use of implantable biosensors in precision medicine. Implantable biosensors are an important class of biosensors because of their ability to provide continuous data on the levels of a target analyte; this enables trends and changes in analyte levels over time to be monitored without any need for intervention from either the patient or clinician. As such, implantable biosensors have great potential in the diagnosis, monitoring, management and treatment of a variety of disease conditions. In this review, we describe precision medicine and the role implantable biosensors may have in this field, along with challenges in their clinical implementation due to the host immune responses they elicit within the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Initiative on Precision Medicine
Collins, F. S., & Varmus, H. (2015) · New England Journal of Medicine · doi:10.1056/nejmp1500523 · Cited by 5,202
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“, 2014); it is these reactions that can lead to biomaterial degradation and device failure (Haas, 2007; Anderson et al., 2008).”
Background(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Gray, L. H., Conger, A. D., Ebert, M., Hornsey, S., & Scott, O. C. A. (1953) · The British Journal of Radiology · doi:10.1259/0007-1285-26-312-638 · Cited by 2,158
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741 · cited 1×
“Because enzymes have highly specific binding pockets, enzyme electrodes have high selectivity against their chosen analyte (Zhu et al., 2015).”
BackgroundElectrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,654
Biosensors and their applications – A review
Mehrotra, P. (2016) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2015.12.002 · Cited by 1,526
The Basic Science of Wound Healing
Broughton, G., Janis, J. E., & Attinger, C. E. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000225430.42531.c2 · Cited by 1,519 · cited 2×
“Macrophages are a key cell mediator of the chronic response to implanted biomaterials, through their roles in foreign body giant cell formation (FBGC), and the production of degradative enzymes and inflammatory mediators such as reactive O2 species (Henson, 1971a; Henson, 1971b; Anderson, 2000; Broughton et al., 2006;…”
Background
Cited by
Graphene-Based Sensors for Human Health Monitoring
Huang, H., Su, S., Wu, N., Wan, H., Wan, S., Bi, H., & Sun, L. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00399 · Cited by 330
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review
Rodrigues, D., Barbosa, A. I., Rebelo, R., Kwon, I. K., Reis, R. L., & Correlo, V. M. (2020) · Biosensors · doi:10.3390/bios10070079 · Cited by 220
Recent Advances in Enabling Technologies in 3D Printing for Precision Medicine
Prendergast, M. E., & Burdick, J. A. (2020) · Advanced Materials · doi:10.1002/adma.201902516 · Cited by 209
Bio‐Multifunctional Smart Wearable Sensors for Medical Devices
Wang, L., Lou, Z., Jiang, K., & Shen, G. (2019) · Advanced Intelligent Systems · doi:10.1002/aisy.201900040 · Cited by 187
Advances in conducting nanocomposite hydrogels for wearable biomonitoring
Roy, A., Afshari, R., Jain, S., Zheng, Y., Lin, M.-H., Zenkar, S., Yin, J., Chen, J., Peppas, N. A., & Annabi, N. (2025) · Chemical Society Reviews · doi:10.1039/d4cs00220b · Cited by 170
Metadata
- Authors
- Gray, M., Meehan, J., Ward, C., Langdon, S. P., Kunkler, I. H., Murray, A., & Argyle, D.
- Venue
- The Veterinary Journal
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 239
- Pages
- 21-29
- ISSN
- 1090-0233 (ISSN-L)
- OpenAlex
- W2884838252
- Cited by
- 169
- References
- 95
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.