Implantable biosensors and their contribution to the future of precision medicine
Open accessThe DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Precision medicine can be defined as the prevention, investigation and treatment of diseases taking individual variability into account. There are multiple ways in which the field of precision medicine may be advanced; however, recent innovations in the fields of electronics and microfabrication techniques have led to an increased interest in the use of implantable biosensors in precision medicine. Implantable biosensors are an important class of biosensors because of their ability to provide continuous data on the levels of a target analyte; this enables trends and changes in analyte levels over time to be monitored without any need for intervention from either the patient or clinician. As such, implantable biosensors have great potential in the diagnosis, monitoring, management and treatment of a variety of disease conditions. In this review, we describe precision medicine and the role implantable biosensors may have in this field, along with challenges in their clinical implementation due to the host immune responses they elicit within the body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Initiative on Precision Medicine
Collins, F. S., & Varmus, H. (2015) · New England Journal of Medicine · doi:10.1056/nejmp1500523 · Cited by 5,202
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“, 2014); it is these reactions that can lead to biomaterial degradation and device failure (Haas, 2007; Anderson et al., 2008).”
Background(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Gray, L. H., Conger, A. D., Ebert, M., Hornsey, S., & Scott, O. C. A. (1953) · The British Journal of Radiology · doi:10.1259/0007-1285-26-312-638 · Cited by 2,158
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741 · cited 1×
“Because enzymes have highly specific binding pockets, enzyme electrodes have high selectivity against their chosen analyte (Zhu et al., 2015).”
BackgroundElectrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,654
Biosensors and their applications – A review
Mehrotra, P. (2016) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2015.12.002 · Cited by 1,526
The Basic Science of Wound Healing
Broughton, G., Janis, J. E., & Attinger, C. E. (2006) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000225430.42531.c2 · Cited by 1,519 · cited 2×
“Macrophages are a key cell mediator of the chronic response to implanted biomaterials, through their roles in foreign body giant cell formation (FBGC), and the production of degradative enzymes and inflammatory mediators such as reactive O2 species (Henson, 1971a; Henson, 1971b; Anderson, 2000; Broughton et al., 2006;…”
BackgroundBiological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465 · cited 1×
“Following implantation of any foreign substance, components of both the acute as well as chronic inflammatory reactions may be elicited (Anderson, 2001).”
BackgroundThe impact of O2 availability on human cancer
Bertout, J. A., Patel, S. A., & Simon, M. C. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2540 · Cited by 1,365
Vaupel, P. W., Schlenger, K., Knoop, C., & Höckel, M. (1991) · PubMed · Cited by 1,118
Nordsmark, M., Bentzen, S. M., Rudat, V., Brizel, D., Lartigau, E., Stadler, P., Becker, A., Adam, M., Molls, M., Dunst, J., et al. (2005) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2005.06.038 · Cited by 953
Tumor microenvironmental physiology and its implications for radiation oncology
Vaupel, P. (2004) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2004.04.008 · Cited by 947 · cited 2×
“Tissue oxygenation is an important component of many cancers (Vaupel, 2004; Bertout et al., 2008).”
BackgroundMEMS-based micropumps in drug delivery and biomedical applications
Nisar, A., Afzulpurkar, N., Mahaisavariya, B., & Tuantranont, A. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.064 · Cited by 614
Kapogiannis, D., & Mattson, M. P. (2011) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70277-5 · Cited by 594 · cited 1×
“in respect to glucose, lactate and pyruvate levels) can have a negative impact on cognitive learning and memory (Hertz and Gibbs, 2009), and is thought to be involved in multiple neurological diseases/disorders (Moretti et al., 2003; Cloix and Hevor, 2009; Kapogiannis and Mattson, 2011).”
BackgroundBiomaterials/Tissue Interactions: Possible Solutions to Overcome Foreign Body Response
Morais, J. M., Papadimitrakopoulos, F., & Burgess, D. J. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9175-3 · Cited by 560
Henson, P. M. (1971) · PubMed · Cited by 514
The phagosome: compartment with a license to kill
Haas, A. (2007) · Traffic · doi:10.1111/j.1600-0854.2006.00531.x · Cited by 450 · cited 1×
“, 2014); it is these reactions that can lead to biomaterial degradation and device failure (Haas, 2007; Anderson et al., 2008).”
BackgroundSong, E., Ouyang, N., Hörbelt, M., Antus, B., Wang, M., & Exton, M. S. (2000) · Cellular Immunology · doi:10.1006/cimm.2000.1687 · Cited by 447
First-in-Human Testing of a Wirelessly Controlled Drug Delivery Microchip
Farra, R., Sheppard, N. F., McCabe, L., Neer, R. M., Anderson, J. M., Santini, J. T., Cima, M. J., & Langer, R. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003276 · Cited by 437
Cellular and Molecular Dynamics in the Foreign Body Reaction
Luttikhuizen, D. T., Harmsen, M. C., & Luyn, M. J. A. V. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1955 · Cited by 396
Anderson, J. M. (2000) · Current Opinion in Hematology · doi:10.1097/00062752-200001000-00008 · Cited by 386 · cited 1×
“Macrophages are a key cell mediator of the chronic response to implanted biomaterials, through their roles in foreign body giant cell formation (FBGC), and the production of degradative enzymes and inflammatory mediators such as reactive O2 species (Henson, 1971a; Henson, 1971b; Anderson, 2000; Broughton et al., 2006;…”
BackgroundEmerging synergy between nanotechnology and implantable biosensors: A review
Vaddiraju, S., Tomazos, I., Burgess, D. J., Jain, F. C., & Papadimitrakopoulos, F. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.001 · Cited by 368
Verma, N., Cowperthwaite, M. C., Burnett, M. G., & Markey, M. K. (2013) · Neuro-Oncology · doi:10.1093/neuonc/nos307 · Cited by 351
The Immunologic Release of Constituents from Neutrophil Leukocytes
Henson, P. M. (1971) · The Journal of Immunology · doi:10.4049/jimmunol.107.6.1535 · Cited by 347
Psychological issues and treatments for people with diabetes
Rubin, R. R., & Peyrot, M. (2001) · Journal of Clinical Psychology · doi:10.1002/jclp.1041 · Cited by 322 · cited 1×
“cal distress and poor patient compliance (Rubin and Peyrot, 2001); non-compliance among diabetic patients has been estimated in the range of 50–80% (Chatterjee, 2006).”
BackgroundApplication of Micro- and Nano-Electromechanical Devices to Drug Delivery
Staples, M., Daniel, K., Cima, M. J., & Langer, R. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9906-4 · Cited by 311
Chronobiology, drug delivery, and chronotherapeutics
Smolensky, M. H., & Peppas, N. A. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.07.001 · Cited by 288
A transparent access chamber for the rat dorsal skin fold
Papenfuss, H. D., Gross, J. F., Intaglietta, M., & Treese, F. A. (1979) · Microvascular Research · doi:10.1016/0026-2862(79)90039-6 · Cited by 281
Characterization of glucose-sensitive insulin release systems in simulated in vivo conditions
Traitel, T., Cohen, Y., & Kost, J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00050-8 · Cited by 253
Henson, P. M. (1971) · PubMed · Cited by 250
Rand, J. S., Kinnaird, E., Baglioni, A., Blackshaw, J., & Priest, J. (2002) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2002.tb02343.x · Cited by 241
Evaluation and applications of radiotelemetry in small laboratory animals
Kramer, K., & Kinter, L. B. (2003) · Physiological Genomics · doi:10.1152/physiolgenomics.00164.2002 · Cited by 221
The Immunologic Release of Constituents from Neutrophil Leukocytes
Henson, P. M. (1971) · The Journal of Immunology · doi:10.4049/jimmunol.107.6.1547 · Cited by 218
The Meaning, Measurement and Modification of Hypoxia in the Laboratory and the Clinic
Hammond, E. M., Asselin, M.-C., Forster, D., O'Connor, J. P. B., Senra, J. M., & Williams, K. J. (2014) · Clinical Oncology · doi:10.1016/j.clon.2014.02.002 · Cited by 217 · cited 1×
“hypoxia, through PET and MRI, allows clinicians to analyse tumour hypoxia across the whole tumour volume (Hammond et al., 2014).”
BackgroundKokkinos, C., Economou, A., & Prodromidis, M. I. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.11.020 · Cited by 214 · cited 1×
“along with the reduced cost of instrumentation, has also furthered interest in their development (Kokkinos et al., 2016).”
BackgroundHome, P. D. (2012) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2012.01580.x · Cited by 212 · cited 1×
“Despite advances in insulin therapy delivery and the development of more physiological insulin preparations (Home, 2012), the avoidance of hypoglycaemic episodes still remains a challenge (Cryer, 2015).”
BackgroundMinimizing Hypoglycemia in Diabetes
International Hypoglycaemia Study Group (2015) · Diabetes Care · doi:10.2337/dc15-0279 · Cited by 209
The chick chorioallantoic membrane as a novel in vivo model for the testing of biomaterials
Valdes, T. I., Kreutzer, D., & Moussy, F. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10152 · Cited by 191 · cited 1×
“, 1979; Ertefai and Gough, 1989) and an avian chorioallantoic membrane (CAM) system of a developing chick embryo (Valdes et al., 2002; Valdes et al., 2003).”
BackgroundAn implantable microdevice to perform high-throughput in vivo drug sensitivity testing in tumors
Jonas, O., Landry, H. M., Fuller, J. E., Santini, J. T., Baselga, J., Tepper, R. I., Cima, M. J., & Langer, R. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.3010564 · Cited by 189 · cited 2×
“A device containing multiple reservoirs capable of releasing drugs into spatially distinct tumour regions at concentrations that could be achieved systemically has been described (Jonas et al., 2015).”
BackgroundMethodKoschwanez, H. E., & Reichert, W. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.034 · Cited by 181 · cited 1×
“Various methods of in vivo biocompatability testing have been developed, such as the cage implant system (Koschwanez and Reichert, 2007), a chamber system (Papenfuss et al.”
MethodHuman genomics projects and precision medicine
Carrasco-Ramiro, F., Peiró-Pastor, R., & Aguado, B. (2017) · Gene Therapy · doi:10.1038/gt.2017.77 · Cited by 166
Gretzer, C., Emanuelsson, L., Liljensten, E., & Thomsen, P. (2006) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856206777346340 · Cited by 165
Patient Adherence to Osteoporosis Medications: Problems, Consequences and Management Strategies
Papaioannou, A., Kennedy, C. C., Dolovich, L., Lau, E., & Adachi, J. D. (2007) · Drugs & Aging · doi:10.2165/00002512-200724010-00003 · Cited by 151
Vaupel, P. W., & Mayer, A. (2014) · Advances in experimental medicine and biology · doi:10.1007/978-1-4939-0620-8_3 · Cited by 150 · cited 1×
“The mechanisms involved in the development of hypoxia in solid tumours include perfusionlimited, diffusion-limited and anaemic hypoxia (Secomb et al., 2012; Vaupel and Mayer, 2014) (Fig.”
BackgroundMomentum grows to make 'personalized' medicine more 'precise'
Katsnelson, A. (2013) · Nature Medicine · doi:10.1038/nm0313-249 · Cited by 143
McNally, A. K., Jones, J. A., MacEwan, S. R., Colton, E., & Anderson, J. M. (2008) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.31658 · Cited by 139
Role of plasma fibronectin in the foreign body response to biomaterials
Keselowsky, B. G., Bridges, A. W., Burns, K. L., Tate, C. C., Babensee, J. E., LaPlaca, M. C., & García, A. J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.04.035 · Cited by 130
Duru, F., Büchi, S., Klaghofer, R., Mattmann, H., Sensky, T., Buddeberg, C., & Candinas, R. (2001) · Heart · doi:10.1136/heart.85.4.375 · Cited by 128
From compliance to concordance in diabetes
Chatterjee, J. S. (2006) · Journal of Medical Ethics · doi:10.1136/jme.2005.012138 · Cited by 127
Affective disorders, antidepressant drugs and brain metabolism
Moretti, A., Gorini, A., & Villa, R. F. (2003) · Molecular Psychiatry · doi:10.1038/sj.mp.4001353 · Cited by 124
Electrocorticographic and deep intracerebral EEG recording in mice using a telemetry system
Weiergräber, M., Henry, M., Hescheler, J., Smyth, N. R., & Schneider, T. (2005) · Brain Research Protocols · doi:10.1016/j.brainresprot.2004.12.006 · Cited by 101 · cited 1×
“Electromyogram (EMG), electroencephalogram (EEG), electrocardiogram (ECG), heart rate, blood pressure, body temperature, activity and circadian rhythm data can be collected using biotelemetry techniques (Bertram and Lothman, 1991; Kramer et al., 2001; Güler and Übeyli, 2002; Kramer and Kinter, 2003; Bastlund et al., 2…”
MethodContinuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects
Kropff, J., & DeVries, J. H. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0345 · Cited by 96
The use of radiotelemetry in small laboratory animals: recent advances.
Kramer, K., Kinter, L. B., Brockway, B. P., Voss, H., Remie, R., & van Zutphen, B. F. M. (2001) · PubMed · Cited by 96
Clinical biomarkers for hypoxia targeting
Le, Q., & Courter, D. L. (2008) · Cancer and Metastasis Reviews · doi:10.1007/s10555-008-9144-9 · Cited by 96 · cited 1×
“Molecular reporters of O2, which form adducts with intracellular macromolecules at low O2 levels, can be detected through immunohistochemistry and represent an indirect method of hypoxic detection, as does the assessment of genes and proteins whose levels are regulated by O2 levels (such as HIF-1 and CAIX) (Le and Cou…”
BackgroundGhasemi, M., Nabipour, I., Omrani, A., Alipour, Z., & Assadi, M. (2016) · PubMed Central · Cited by 95
Ngoepe, M., Choonara, Y., Tyagi, C., Tomar, L., Du Toit, L., Kumar, P., Ndesendo, V., & Pillay, V. (2013) · Sensors · doi:10.3390/s130607680 · Cited by 92
(1937) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.27.3.271 · Cited by 92
Histories of cochlear implantation
Blume, S. S. (1999) · Social Science & Medicine · doi:10.1016/s0277-9536(99)00164-1 · Cited by 88
Groothuis, D. R., Benalcazar, H., Allen, C. V., Wise, R. M., Dills, C. V., Dobrescu, C., Rothholtz, V. S., & Levy, R. M. (2000) · Brain Research · doi:10.1016/s0006-8993(99)02089-2 · Cited by 83
Epilepsy, Regulation of Brain Energy Metabolism and Neurotransmission
Cloix, J., & Hévor, T. (2009) · Current Medicinal Chemistry · doi:10.2174/092986709787549316 · Cited by 82
Evaluation of a continuous glucose monitoring system for use in dogs, cats, and horses
Wiedmeyer, C. E., Johnson, P. J., Cohn, L. A., & Meadows, R. L. (2003) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.2003.223.987 · Cited by 80 · cited 1×
“Although CGM systems for veterinary patients are not in mainstream use, they have been successfully used in clinics (Davison et al., 2003; Wiedmeyer et al., 2003; Wiedmeyer and DeClue, 2008).”
BackgroundTelemetry for Cardiovascular Monitoring in a Pharmacological Study: New Approaches to Data Analysis
Anderson, N., Devlin, A. M., Graham, D., Morton, J. J., Hamilton, C., Reid, J. L., Schork, N. J., & Dominiczak, A. F. (1999) · Hypertension · doi:10.1161/01.hyp.33.1.248 · Cited by 76
The use of radiotelemetry to evaluate electrographic seizures in rats with kainate-induced epilepsy
Williams, P. A., White, A., Ferraro, D. J., Clark, S., Staley, K. J., & Dudek, F. E. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.12.035 · Cited by 74 · cited 1×
“Biotelemetry has been shown to be of value in the characterisation of various animal models of human diseases, including epilepsy, sleep disorders, neurodegenerative and neuropsychiatric disorders (Güler and Übeyli, 2002; Bastlund et al., 2004; Williams et al., 2006).”
BackgroundWhat learning in day‐old chickens can teach a neurochemist: focus on astrocyte metabolism
Hertz, L., & Gibbs, M. E. (2009) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2009.05939.x · Cited by 73 · cited 1×
“in respect to glucose, lactate and pyruvate levels) can have a negative impact on cognitive learning and memory (Hertz and Gibbs, 2009), and is thought to be involved in multiple neurological diseases/disorders (Moretti et al.”
BackgroundBassett, L., Troncy, É., Pouliot, M., Paquette, D., Ascah, A., & Authier, S. (2014) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2014.07.005 · Cited by 71
Evaluation of day-to-day variability of serial blood glucose concentration curves in diabetic dogs
Fleeman, L. M., & Rand, J. S. (2003) · Journal of the American Veterinary Medical Association · doi:10.2460/javma.2003.222.317 · Cited by 70
Implantable diagnostic device for cancer monitoring
Daniel, K. D., Kim, G., Vassiliou, C. C., Galindo, M., Guimarães, A. R., Weissleder, R., Charest, A., Langer, R., & Cima, M. J. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.010 · Cited by 69
Sedlaczek, P., Frydecka, I., Gabryś, M. S., van Dalen, A., EINARSSON, R., & Harlozinska, A. (2002) · Cancer · doi:10.1002/cncr.10917 · Cited by 69
Lundt, A., Wormuth, C., Siwek, M. E., Müller, R., Ehninger, D., Henseler, C., Broich, K., Papazoglou, A., & Weiergräber, M. (2015) · Neural Plasticity · doi:10.1155/2016/8213878 · Cited by 68 · cited 2×
“Electromyogram (EMG), electroencephalogram (EEG), electrocardiogram (ECG), heart rate, blood pressure, body temperature, activity and circadian rhythm data can be collected using biotelemetry techniques (Bertram and Lothman, 1991; Kramer et al., 2001; Güler and Übeyli, 2002; Kramer and Kinter, 2003; Bastlund et al., 2…”
BackgroundMethodTheory and Applications of Biotelemetry
Güler, N. F., & Übeylı, E. D. (2002) · Journal of Medical Systems · doi:10.1023/a:1014862027454 · Cited by 64 · cited 2×
“Biotelemetry has been shown to be of value in the characterisation of various animal models of human diseases, including epilepsy, sleep disorders, neurodegenerative and neuropsychiatric disorders (Güler and Übeyli, 2002; Bastlund et al., 2004; Williams et al., 2006).”
BackgroundMethodIntracranial MEMS based temozolomide delivery in a 9L rat gliosarcoma model
Masi, B. C., Tyler, B. M., Bow, H., Wicks, R. T., Xue, Y., Brem, H., Langer, R., & Cima, M. J. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.04.048 · Cited by 64
Evaluation of a continuous glucose monitoring system in diabetic dogs
Davison, L. J., Slater, L. A., HERRTAGE, M. E., Church, D. B., Judge, S., Ristic, J. M. E., & Catchpole, B. (2003) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.2003.tb00102.x · Cited by 63
Molecular Imaging of the Tumor Microenvironment for Precision Medicine and Theranostics
(2014) · Advances in Cancer Research · doi:10.1016/b978-0-12-411638-2.00007-0 · Cited by 61
Inhibition of pH regulation as a therapeutic strategy in hypoxic human breast cancer cells
Meehan, J., Ward, C., Turnbull, A., Wills, J. C., Finch, A. J., Jarman, E. J., Xintaropoulou, C., Martínez-Pérez, C., Gray, M., Pearson, M. W., et al. (2017) · Oncotarget · doi:10.18632/oncotarget.17143 · Cited by 61
Self-citationStructural Adaptation of Normal and Tumour Vascular Networks
Secomb, T. W., Dewhirst, M. W., & Pries, A. R. (2011) · Basic & Clinical Pharmacology & Toxicology · doi:10.1111/j.1742-7843.2011.00815.x · Cited by 61
Cordeiro, C. A., de Vries, M. G., Wahono, N., Oomen, P. E., Cremers, T. I. F. H., & Westerink, B. H. C. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.101 · Cited by 54
New-generation diabetes management: glucose sensor-augmented insulin pump therapy
Cengiz, E., Sherr, J. L., Weinzimer, S. A., & Tamborlane, W. V. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.22 · Cited by 53
Ertefai, S., & Gough, D. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90097-6 · Cited by 52
Continuous Glucose Monitoring in Dogs and Cats
Wiedmeyer, C. E., & DeClue, A. E. (2008) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.0001.x · Cited by 51 · cited 1×
“Although CGM systems for veterinary patients are not in mainstream use, they have been successfully used in clinics (Davison et al., 2003; Wiedmeyer et al., 2003; Wiedmeyer and DeClue, 2008).”
BackgroundMonitoring Methods for Dogs and Cats with Diabetes Mellitus
Cook, A. K., & Dip. ACVIM-SAIM, D. E.-C. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600302 · Cited by 45
Fructosamine and glycated hemoglobin in the assessment of glycaemic control in dogs
Montoya, A. L., & Marca, M. C. (2001) · Veterinary Research · doi:10.1051/vetres:2001109 · Cited by 44 · cited 1×
“To overcome some of the issues outlined with blood glucose measurements in dogs and cats, glycosylated proteins such as glycosylated haemoglobin and fructosamine concentrations can be measured to give a quantitative indirect assessment of diabetes diagnosis and management (Thoresen and Bredal, 1996; Loste and Marca, 2…”
BackgroundDEHENNIS, A. D., Mortellaro, M. A., & Ioacără, S. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815596760 · Cited by 44
Ex ova chick chorioallantoic membrane as a novel in vivo model for testing biosensors
Valdes, T. I., Klueh, U., Kreutzer, D. L., & Moussy, F. G. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10055 · Cited by 40 · cited 1×
“, 1979; Ertefai and Gough, 1989) and an avian chorioallantoic membrane (CAM) system of a developing chick embryo (Valdes et al., 2002; Valdes et al., 2003).”
BackgroundOoi, S. L., He, H. G., Dong, Y., & Wang, W. (2016) · Health and Quality of Life Outcomes · doi:10.1186/s12955-016-0561-0 · Cited by 38
Bastlund, J. F., Jennum, P., Mohapel, P., Vogel, V., & Watson, W. P. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.03.004 · Cited by 37
Cavallini, A., Jost, T. R., Ghoreishizadeh, S. S., Olivo, J., de Beeck, M. O., Gorissen, B., Grassi, F., Micheli, G. D., & Carrara, S. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2339638 · Cited by 33
The Applications of BioMEMS in Diagnosis, Cell Biology, and Therapy: A Review
Menon, K., Joy, R. A., Sood, N., & Mittal, R. K. (2013) · BioNanoScience · doi:10.1007/s12668-013-0112-7 · Cited by 29
Kamendi, H., Brott, D., Chen, Y., Litwin, D. C., Lengel, D., Fonck, C., Bui, K., Gorko, M. A., & Bialecki, R. (2010) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2010.04.014 · Cited by 27 · cited 1×
“One study, using radiotelemetry combined with an automatic blood sampler and urine analysis, demonstrated the feasibility of recording multiple telemetric and non-telemetric physiological parameters simultaneously (Kamendi et al., 2010).”
MethodImplantable Microsystems for Personalised Anticancer Therapy
Marland, J. R. K., Blair, E. O., Flynn, B. W., González‐Fernández, E., Huang, L., Kunkler, I. H., Smith, S., Staderini, M., Tsiamis, A., Ward, C., et al. (2017) · Springer eBooks · doi:10.1007/978-3-319-67723-1_11 · Cited by 20
Self-citationDeletion of the chemokine receptor CCR2 attenuates foreign body reaction to implants in mice
Castro, P. R., Marques, S. M., Viana, C. T. R., Campos, P. P., Ferreira, M. A. N. D., Barcelos, L. S., & Andrade, S. P. (2014) · Microvascular Research · doi:10.1016/j.mvr.2014.07.002 · Cited by 19
Bally, L., Thabit, H., Tauschmann, M., Allen, J. M., Hartnell, S., Wilinska, M. E., Exall, J., Huegel, V., Sibayan, J., Borgman, S. K., et al. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-016738 · Cited by 17
Jenney (2000) · doi:10.1002/(sici)1097-4636(20000315)49:4<435::aid-jbm2>3.0.co;2-y
Cited by
Graphene-Based Sensors for Human Health Monitoring
Huang, H., Su, S., Wu, N., Wan, H., Wan, S., Bi, H., & Sun, L. (2019) · Frontiers in Chemistry · doi:10.3389/fchem.2019.00399 · Cited by 330
Nonspecific Binding—Fundamental Concepts and Consequences for Biosensing Applications
Frutiger, A., Tanno, A., Hwu, S., Tiefenauer, R. F., Vörös, J., & Nakatsuka, N. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00044 · Cited by 278
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Skin-Integrated Wearable Systems and Implantable Biosensors: A Comprehensive Review
Rodrigues, D., Barbosa, A. I., Rebelo, R., Kwon, I. K., Reis, R. L., & Correlo, V. M. (2020) · Biosensors · doi:10.3390/bios10070079 · Cited by 220
Recent Advances in Enabling Technologies in 3D Printing for Precision Medicine
Prendergast, M. E., & Burdick, J. A. (2020) · Advanced Materials · doi:10.1002/adma.201902516 · Cited by 209
Metadata
- Authors
- Gray, M., Meehan, J., Ward, C., Langdon, S. P., Kunkler, I. H., Murray, A., & Argyle, D.
- Venue
- The Veterinary Journal
- Publisher
- Elsevier BV
- Published
- 2018-09
- Volume
- 239
- Pages
- 21-29
- ISSN
- 1090-0233 (ISSN-L)
- OpenAlex
- W2884838252
- Cited by
- 169
- References
- 95
- FWCI
- 5.46
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.