A review of outdoor thermal comfort indices and neutral ranges for hot-humid regions
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
This paper reviews frequently used outdoor thermal comfort indices in hot-humid regions and neutral thermal ranges to offer guidelines for selecting an appropriate index for hot-humid regions. An overview of the development of outdoor thermal comfort (OTC) indices based on type of approach, from linear equation approach - to adaptive thermal comfort model – is provided and the advantages and limitations of each index are presented. Subjective neutral ranges from 31 studies conducted in hot-humid regions were assessed on the basis of geographical location, Koppen-Geiger's climate classification, parameters, a survey method, instrumentation set-up, respondent profile, method of analysis, neutral range, and coefficient of determinations in order to gain an understanding of their deviations. The review of 31 calibration studies of (m)PET's, (OUT_)SET*’s and UTCI's neutral ranges indicated that the lower threshold of (m)PET's neutral range needs to be lowered, while the lower threshold of (OUT_)SET*’s and UTCI's ranges should be raised. The appropriateness of (OUT_)SET*’s thermal range for hot climates was proven by its full-coverage neutral range in the evaluation. However, the accurate response to ambient thermal conditions was determined by the advancement of a human thermoregulatory model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Sample size estimation and power analysis for clinical research studies
Suresh, K., & Chandrashekara, S. (2012) · Journal of Human Reproductive Sciences · doi:10.4103/0974-1208.97779 · Cited by 1,024
RetractedUpdated world map of the Köppen-Geiger climate classification
Peel, M. C., Finlayson, B. L., & McMahon, T. A. (2007) · doi:10.5194/hessd-4-439-2007 · Cited by 13,640
Comparison of UTCI to selected thermal indices
Blazejczyk, K., Epstein, Y., Jendritzky, G., Staiger, H., & Tinz, B. (2012) · International Journal of Biometeorology · doi:10.1007/s00484-011-0453-2 · Cited by 1,129
UTCI-Fiala multi-node model of human heat transfer and temperature regulation
Fiala, D., Havenith, G., Bröde, P., Kampmann, B., & Jendritzky, G. (2012) · International Journal of Biometeorology · doi:10.1007/s00484-011-0424-7 · Cited by 994
Outdoor thermal comfort in public space in warm-humid Guayaquil, Ecuador
Johansson, E., Yahia, M. W., Arroyo, I., & Bengs, C. (2018) · International Journal of Biometeorology · doi:10.1007/s00484-017-1329-x · Cited by 149
Considering individual physiological differences in a human thermal model
Zhang, H., Huizenga, C., Arens, E., & Yu, T. (2001) · Journal of Thermal Biology · doi:10.1016/s0306-4565(01)00051-1 · Cited by 140
Nicol, J. F., & Roaf, S. (2017) · Building Research & Information · doi:10.1080/09613218.2017.1301698 · Cited by 133
The use of correlation functions in thoracic surgery research.
(2015) · PubMed Central · doi:10.3978/j.issn.2072-1439.2015.01.54 · Cited by 19
Metadata
- Authors
- Binarti, F., Koerniawan, M. D., Triyadi, S., Utami, S. S., & Matzarakis, A.
- Venue
- Urban Climate
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 31
- Pages
- 100531
- ISSN
- 2212-0955 (ISSN-L)
- OpenAlex
- W2989891582
- Cited by
- 247
- References
- 8
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of outdoor thermal comfort indices and neutral ranges for hot-humid regions. https://app.cochat.ai/papers/10.1016/j.uclim.2019.100531
- The paper
- Binarti, F., Koerniawan, M. D., Triyadi, S., Utami, S. S., & Matzarakis, A. (2020). A review of outdoor thermal comfort indices and neutral ranges for hot-humid regions. Urban Climate. https://doi.org/10.1016/j.uclim.2019.100531
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.