The DOI matches its Crossref record.
High-intensity focused ultrasound for the treatment of liver tumours
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PEGylation as a strategy for improving nanoparticle-based drug and gene delivery
Suk, J. S., Xu, Q., Kim, N., Hanes, J., & Ensign, L. M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.012 · Cited by 4,523
High-intensity focused ultrasound in the treatment of solid tumours
Kennedy, J. E. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1591 · Cited by 1,282
Self-citationTherapeutic applications of ultrasound
ter Haar, G. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.005 · Cited by 721
Self-citationIlling, R. O., Kennedy, J. E., Wu, F., ter Haar, G. R., Protheroe, A. S., Friend, P. J., Gleeson, F. V., Cranston, D. W., Phillips, R. R., & Middleton, M. R. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602803 · Cited by 584
Self-citationMagnetic Nanoparticles in Cancer Theranostics
Gobbo, O. L., Sjaastad, K., Radomski, M. W., Volkov, Y., & Prina-Mello, A. (2015) · Theranostics · doi:10.7150/thno.11544 · Cited by 462
Metadata
- Authors
- Kennedy, J. E., Wu, F., ter Haar, G. R., Gleeson, F. V., Phillips, R. R., Middleton, M. R., & Cranston, D.
- Venue
- Ultrasonics
- Publisher
- Elsevier BV
- Published
- 2004-04
- Volume
- 42
- Issue
- 1-9
- Pages
- 931-935
- ISSN
- 0041-624X (ISSN-L)
- OpenAlex
- W2004170475
- Cited by
- 435
- References
- 0
- FWCI
- 15.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-intensity focused ultrasound for the treatment of liver tumours. https://app.cochat.ai/papers/10.1016/j.ultras.2004.01.089
- The paper
- Kennedy, J. E., Wu, F., ter Haar, G. R., Gleeson, F. V., Phillips, R. R., Middleton, M. R., & Cranston, D. (2004). High-intensity focused ultrasound for the treatment of liver tumours. Ultrasonics. https://doi.org/10.1016/j.ultras.2004.01.089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.