Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 279

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Medical breast ultrasound image segmentation by machine learning

Open access
Xu, Yuan, Wang, Yuxin, Yuan, Jie, Cheng, Qian, Wang, Xueding, Carson, Paul L.·2019·Ultrasonics

Abstract

HighlightsA machine learning based method to automatically segment 3D breast ultrasound image.Might help assist clinical diagnose breast cancer in the future.Segmentation results demonstrate good consistency with ground truth. ABSTRACT Breast cancer is the most commonly diagnosed cancer, which alone accounts for 30% all new cancer diagnoses for women, posing a threat to women’s health. Segmentation of breast ultrasound images into functional tissues can aid tumor localization, breast density measurement, and assessment of treatment response, which is important to the clinical diagnosis of breast cancer. However, manually segmenting the ultrasound images, which is skill and experience dependent, would lead to a subjective diagnosis; in addition, it is time‐consuming for radiologists to review hundreds of clinical images. Therefore, automatic segmentation of breast ultrasound images into functional tissues has received attention in recent years, amidst the more numerous studies of detection and segmentation of masses. In this paper, we propose to use convolutional neural networks (CNNs) for segmenting breast ultrasound images into four major tissues: skin, fibroglandular tissue, mass, and fatty tissue, on three‐dimensional (3D) breast ultrasound images. Quantitative metrics for evaluation of segmentation results including Accuracy, Precision, Recall, and Symbol, all reached over 80%, which indicates that the method proposed has the capacity to distinguish functional tissues in breast ultrasound images. Another metric called the Jaccard similarity index (JSI) yields an 85.1% value, outperforming our previous study using the watershed algorithm with 74.54% JSI value. Thus, our proposed method might have the potential to provide the segmentations necessary to assist the clinical diagnosis of breast cancer and improve imaging in other modes in medical ultrasound. Symbol. No Caption available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultras.2018.07.006

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 279

Metadata

Authors
Xu, Y., Wang, Y., Yuan, J., Cheng, Q., Wang, X., & Carson, P. L.
Venue
Ultrasonics
Publisher
Elsevier BV
Published
2019-01
Volume
91
Pages
1-9
ISSN
0041-624X (ISSN-L)
OpenAlex
W2883547127
Cited by
279
References
26
FWCI
12.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Medical breast ultrasound image segmentation by machine learning. https://app.cochat.ai/papers/10.1016/j.ultras.2018.07.006
The paper
Xu, Y., Wang, Y., Yuan, J., Cheng, Q., Wang, X., & Carson, P. L. (2019). Medical breast ultrasound image segmentation by machine learning. Ultrasonics. https://doi.org/10.1016/j.ultras.2018.07.006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.