CoChat

Focused-Ultrasound Disruption of the Blood-Brain Barrier Using Closely-Timed Short Pulses: Influence of Sonication Parameters and Injection Rate

Open access
O’Reilly, Meaghan A., Waspe, Adam C., Ganguly, Milan, Hynynen, Kullervo · 2011 · Ultrasound in Medicine & Biology
Cited by 121

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Blood brain barrier disruption (BBBD) shows promise for drug delivery in the brain, however optimal parameters for disruption have yet to be firmly established. Previous work has shown that BBBD can be achieved using bursts comprised of microsecond length pulses at 50% duty cycle in order to eliminate standing waves and variability. The capabilities and limitations of this sort of pulse sequence comprising short bursts were examined. Ultrasound induced BBBD was performed in 28 rats using Definity contrast agent. The spacing between 3 μs pulses at 1.18 MHz was either 6 μs, 60 μs, 300 μs, 600 μs during a 10 ms pulse, or 1 s for a single pulse burst. The rate of infusion of the microbubbles was also examined, as well as the burst PRF under infusion conditions. A semi-log relationship between enhancement mean and the number of cycles in a burst was discovered, with a 1 pulse burst (i.e. a 3 μs burst at 1 Hz) still capable of disrupting the BBB. No increased efficacy or safety benefit over bursts containing more cycles was found, however. Microbubble infusions showed no improvement in T1w enhancement, but did improve consistency. Increased burst PRF combined with infusion improved T1w enhancement but without statistical significance, while a decrease in burst PRF showed a statistically significant decrease in enhancement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultrasmedbio.2011.01.008

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 121

Metadata

Authors
O’Reilly, M. A., Waspe, A. C., Ganguly, M., & Hynynen, K.
Venue
Ultrasound in Medicine & Biology
Publisher
Elsevier BV
Published
2011-04
Volume
37
Issue
4
Pages
587-594
ISSN
0301-5629 (ISSN-L)
OpenAlex
W2056416291
Cited by
121
References
2
FWCI
4.38
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Focused-Ultrasound Disruption of the Blood-Brain Barrier Using Closely-Timed Short Pulses: Influence of Sonication Parameters and Injection Rate. https://app.cochat.ai/papers/10.1016/j.ultrasmedbio.2011.01.008
The paper
O’Reilly, M. A., Waspe, A. C., Ganguly, M., & Hynynen, K. (2011). Focused-Ultrasound Disruption of the Blood-Brain Barrier Using Closely-Timed Short Pulses: Influence of Sonication Parameters and Injection Rate. Ultrasound in Medicine & Biology. https://doi.org/10.1016/j.ultrasmedbio.2011.01.008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.