Decafluorobutane as a Phase-Change Contrast Agent for Low-Energy Extravascular Ultrasonic Imaging
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Currently available microbubbles used for ultrasound imaging and therapeutics are limited to intravascular space due to their size distribution in the micron range. Phase-change contrast agents (PCCAs) have been proposed as a means to overcome this limitation, since droplets formed in the hundred nanometer size range might be able to extravasate through leaky microvasculature, after which they could be activated to form larger highly echogenic microbubbles. Existing PCCAs in the sub-micron size range require substantial acoustic energy to be vaporized, increasing the likelihood of unwanted bioeffects. Thus, there exists a need for PCCAs with reduced acoustic activation energies for use in imaging studies. In this article, it is shown that decafluorobutane, which is normally a gas at room temperature, can be incorporated into metastable liquid sub-micron droplets with appropriate encapsulation methods. The resulting droplets are activatable with substantially less energy than other favored PCCA compounds. Decafluorobutane nanodroplets may present a new means to safely extend ultrasound imaging beyond the vascular space. (E-mail: padayton@bme.unc.edu)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of chemistry and physics
(1930) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(30)91499-8 · Cited by 11,721
Nist chemistry webbook, nist standard reference database number 69
Linstorm, P. (1998) · Medical Entomology and Zoology · Cited by 4,606
Handbook of Chemistry and Physics.
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-934_3 · Cited by 2,559
Regulation of transport pathways in tumor vessels: Role of tumor type and microenvironment
Hobbs, S. K., Monsky, W. L., Yuan, F., Roberts, W. G., Griffith, L., Torchilin, V. P., & Jain, R. K. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4607 · Cited by 2,438 · cited 1×
“Many tumor types exhibit characteristically permeable vasculature, with endothelial gaps typically between 200–600 nm and show poor lymphatic clearance, also known as the enhanced permeability and retention (EPR) effect (Hobbs et al. 1998; Campbell 2006; Torchilin 2010).”
BackgroundUltrasound Microbubble Contrast Agents: Fundamentals and Application to Gene and Drug Delivery
Ferrara, K., Pollard, R., & Borden, M. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095852 · Cited by 1,288 · cited 1×
“Beyond imaging, microbubbles have demonstrated substantial potential for use in therapeutic applications such as drug delivery, gene delivery and thrombolysis (Ferrara et al. 2007; Hitchcock and Holland 2010; Sirsi and Borden 2009; Stride and Coussios 2010; Tinkov et al. 2009).”
BackgroundMicrobubble compositions, properties and biomedical applications
Sirsi, S. R., & Borden, M. A. (2009) · Bubble Science, Engineering & Technology · doi:10.1179/175889709x446507 · Cited by 594 · cited 1×
“Beyond imaging, microbubbles have demonstrated substantial potential for use in therapeutic applications such as drug delivery, gene delivery and thrombolysis (Ferrara et al. 2007; Hitchcock and Holland 2010; Sirsi and Borden 2009; Stride and Coussios 2010; Tinkov et al. 2009).”
BackgroundPassive and Active Drug Targeting: Drug Delivery to Tumors as an Example
Torchilin, V. P. (2010) · Handbook of Experimental Pharmacology · doi:10.1007/978-3-642-00477-3_1 · Cited by 573 · cited 1×
“Many tumor types exhibit characteristically permeable vasculature, with endothelial gaps typically between 200–600 nm and show poor lymphatic clearance, also known as the enhanced permeability and retention (EPR) effect (Hobbs et al. 1998; Campbell 2006; Torchilin 2010).”
BackgroundAcoustic droplet vaporization for therapeutic and diagnostic applications
Kripfgans, O. D., Fowlkes, J. B., Miller, D. L., Eldevik, O. P., & Carson, P. L. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00262-3 · Cited by 572 · cited 3×
“2006), ultrasound frequency, peak negative pressure and pulse length (Kripfgans et al. 2000; Giesecke and Hynynen 2003; Lo et al. 2007; Fabiilli et al. 2009; Schad and Hynynen 2010) can have on the vaporization threshold for a particular droplet or droplet emulsion.”
BackgroundControlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
Rapoport, N. Y., Kennedy, A. M., Shea, J. E., Scaife, C. L., & Nam, K.-H. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.026 · Cited by 551 · cited 3×
“…correction (Kripfgans et al. 2002; Haworth et al. 2008), occlusion therapy (Kripfgans et al. 2005; Zhang et al. 2010), therapeutic drug delivery (Rapoport et al. 2009b; Fabiilli et al. 2010a, 2010b), and high-intensity focused ultrasound (HIFU) and lithotripsy-based nucleation agents to enhance…”
BackgroundMethodMicrobubble-enhanced US in Body Imaging: What Role?
Wilson, S. R., & Burns, P. N. (2010) · Radiology · doi:10.1148/radiol.10091210 · Cited by 470 · cited 1×
“…contrast agents for ultrasound (US) have been extensively explored and show promising results in applications ranging from echocardiography to molecular imaging of highly-vascularized tumors (Lindner 2009; Sboros and Tang 2010; Staub et al. 2010; Gessner and Dayton 2010; Wilson and Burns 2010).”
Background
Cited by
Sheeran, P. S., Luois, S., Dayton, P. A., & Matsunaga, T. O. (2011) · Langmuir · doi:10.1021/la2013705 · Cited by 309
Self-citationDesign of ultrasonically-activatable nanoparticles using low boiling point perfluorocarbons
Sheeran, P. S., Luois, S. H., Mullin, L. B., Matsunaga, T. O., & Dayton, P. A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.021 · Cited by 254
Self-citationPhase-Change Contrast Agents for Imaging and Therapy
S. Sheeran, P., & A.Dayton, P. (2012) · Current Pharmaceutical Design · doi:10.2174/138161212800099883 · Cited by 253
Stimuli-responsive nanobubbles for biomedical applications
Xiong, R., Xu, R. X., Huang, C., De Smedt, S., & Braeckmans, K. (2021) · Chemical Society Reviews · doi:10.1039/c9cs00839j · Cited by 236
Williams, R., Wright, C., Cherin, E., Reznik, N., Lee, M., Gorelikov, I., Foster, F. S., Matsuura, N., & Burns, P. N. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.10.004 · Cited by 166
Chen, C. C., Sheeran, P. S., Wu, S.-Y., Olumolade, O. O., Dayton, P. A., & Konofagou, E. E. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.09.025 · Cited by 163
“Acoustic nanodroplet vaporization was investigated in vitro using an experimental setup described previously [39].”
Self-citation
Metadata
- Authors
- Sheeran, P. S., Wong, V. P., Luois, S., McFarland, R. J., Ross, W. D., Feingold, S., Matsunaga, T. O., & Dayton, P. A.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2011-09
- Volume
- 37
- Issue
- 9
- Pages
- 1518-1530
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2076728050
- Cited by
- 244
- References
- 31
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.