Training Midwives to Perform Basic Obstetric Point-of-Care Ultrasound in Rural Areas Using a Tablet Platform and Mobile Phone Transmission Technology—A WFUMB COE Project
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Point-of-care ultrasound (POCUS) has become a topical subject and can be applied in a variety of ways with differing outcomes. The cost of all diagnostic procedures including obstetric ultrasound examinations is a major factor in the developing world and POCUS is only useful if it can be equated to good outcomes at a lower cost than a routine obstetric examination. The aim of this study was to assess a number of processes including accuracy of images and reports generated by midwives, performance of a tablet-sized ultrasound scanner, training of midwives to complete ultrasounds, teleradiology solution transmissions of images via internet, review of images by a radiologist, communication between midwife and radiologist, use of this technique to identify high-risk patients and improvement of the education and teleradiology model components. The midwives had no previous experience in ultrasound. They were stationed in rural locations where POCUS was available for the first time. After scanning the patients, an interim report was generated by the midwives and sent electronically together with all images to the main hospital for validation. Unique software was used to send lossless images by mobile phone using a modem. Transmission times were short and quality of images transmitted was excellent. All reports were validated by two experienced radiologists in our department and returned to the centers using the same transmission software. The transmission times, quality of scans, quality of reports and other parameters were recorded and monitored. Analysis showed excellent correlation between provisional and validated reports. Reporting accuracy of scans performed by the midwives was 99.63%. Overall flow turnaround time (from patient presentation to validated report) was initially 35 min but reduced to 25 min. The unique mobile phone transmission was faultless and there was no degradation of image quality. We found excellent correlation between final outcomes of the pregnancies and diagnoses on the basis of reports generated by the midwives. Only 1 discrepancy was found in the midwives' reports. Scan results versus actual outcomes revealed 2 discrepancies in the 20 patients identified as high risk. In conclusion, we found that it is valuable to train midwives in POCUS to use an ultrasound tablet device and transmit images and reports via the internet to radiologists for review of accuracy. This focus on the identification of high-risk patients can be valuable in a remote healthcare facility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Image acquisition can be taught from a distance via the internet and a telemedicine platform is reliably able to transmit high quality images (29, 34, 37, 38).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [38]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In an attempt to overcome such challenges, ultrasound training programs have taught non-experts either to independently perform obstetric ultrasounds to screen for high-risk pregnancies (52–55) or to utilize tele-ultrasound (29, 34, 37, 38).”
From Tele-Ultrasound in Resource-Limited Settings: A Systematic Review (2019) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review article: Use of ultrasound in the developing world
Sippel, S., Muruganandan, K., Levine, A., & Shah, S. (2011) · International Journal of Emergency Medicine · doi:10.1186/1865-1380-4-72 · Cited by 352
A review of training opportunities for ultrasonography in low and middle income countries
LaGrone, L. N., Sadasivam, V., Kushner, A. L., & Groen, R. S. (2012) · Tropical Medicine & International Health · doi:10.1111/j.1365-3156.2012.03014.x · Cited by 142 · cited 1×
“…had to be assessed toward the end of the training period and several similar trainings have been described by other authors (Hediger et al. 2016; LaGrone et al. 2012; Parker and Harrison 2015; Rijken et al. 2009; Shaw-Battista 2015); yet no data have been published stating an ideal time frame…”
Best practice in maternal–fetal medicine
FIGO Working Group on Best Practice in Maternal–Fetal Medicine (2014) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2014.10.011 · Cited by 113
Obstetric ultrasound scanning by local health workers in a refugee camp on the Thai-Burmese border.
Rijken, M. J., Lee, S. J., Boel, M. E., Papageorghiou, A. T., Visser, G. H. A., Dwell, S. L. M., Kennedy, S. H., Singhasivanon, P., White, N. J., Nosten, F., et al. (2009) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.7350 · Cited by 108 · cited 3×
“Indeed, this is the practice in most developed economies; however, many women in low resource regions especially in sub-Saharan Africa will still go through pregnancy without the benefit of even a single ultrasound examination (Ostensen 2000; Rijken et al. 2009; Sippel, et al. 2011).”
BackgroundMethodACOG Practice Bulletin No. 101: Ultrasonography in Pregnancy
(2009) · Obstetrics & Gynecology · doi:10.1097/00006250-200902000-00033 · Cited by 93
Shaw‐Battista, J., Young‐Lin, N., Bearman, S., Dau, K. Q., & Vargas, J. (2015) · Journal of Midwifery & Women s Health · doi:10.1111/jmwh.12395 · Cited by 66
Nathan, R., Swanson, J. O., Swanson, D. L., McClure, E. M., Bolamba, V. L., Lokangaka, A. L., Pineda, I. S., Figueroa, L., López-Gomez, W., Garcés, A., et al. (2016) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2016.11.001 · Cited by 56
Ultrasound Quality Assurance (QA) for Singletons in the NICHD Fetal Growth Studies
Hediger, M., Fuchs, K., Grantz, K., Grewal, J., Kim, S., Gore-Langton, R. E., Louis, G. B. B., D'Alton, M., & Albert, P. S. (2016) · Journal of ultrasound in medicine · doi:10.7863/ultra.15.09087 · Cited by 48 · cited 3×
“The open-ended timeline had to be assessed toward the end of the training period and several similar trainings have been described by other authors (Hediger et al. 2016; LaGrone et al. 2012; Parker and Harrison 2015; Rijken et al. 2009; Shaw-Battista 2015); yet no data have been published stating…”
MethodResultDiagnostic Ultrasound at MACH 20: Retroperitoneal and Pelvic Imaging in Space
Jones, J. A., Sargsyan, A. E., Barr, Y., Melton, S. L., Hamilton, D. R., Dulchavsky, S. A., & Whitson, P. A. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2009.01.002 · Cited by 46
Øyen, L., & Aune, I. (2015) · Sexual & Reproductive Healthcare · doi:10.1016/j.srhc.2015.10.003 · Cited by 43
Research works printed but not linked: 1
- Cunningham F, Leveno KJ, Bloom SL, Spong CY, Dashe JS, Hoffman BL, Casey BM, Sheffield JS. Fetal imaging, Williams ob- stetrics. 24th edition. New York: McGraw-Hill 2013.
Cited by
Tele-Ultrasound in Resource-Limited Settings: A Systematic Review
Britton, N., Miller, M. A., Safadi, S., Siegel, A., Levine, A. R., & McCurdy, M. T. (2019) · Frontiers in Public Health · doi:10.3389/fpubh.2019.00244 · Cited by 166
“In an attempt to overcome such challenges, ultrasound training programs have taught nonexperts either to independently perform obstetric ultrasounds to screen for high-risk pregnancies (52–55) or to utilize teleultrasound (29, 34, 37, 38).”
BackgroundAbrokwa, S. K., Ruby, L. C., Heuvelings, C. C., & Bélard, S. (2022) · EClinicalMedicine · doi:10.1016/j.eclinm.2022.101333 · Cited by 140
Diagnostic Ultrasound Safety Review for Point‐of‐Care Ultrasound Practitioners
Miller, D. L., Abo, A. M., Abramowicz, J. S., Bigelow, T. A., Dalecki, D., Dickman, E., Donlon, J., Harris, G. R., & Nomura, J. T. (2019) · Journal of Ultrasound in Medicine · doi:10.1002/jum.15202 · Cited by 103
“A particularly exciting aspect of POCUS is that appropriate training including safety and image interpretation potentially can be given to many nonphysician medical personnel and can bring the benefits of POCUS to virtually any patient in need: for example, in remote rural areas.(105,106)”
BackgroundPoint-of-care ultrasound in obstetrics and gynecology
Recker, F., Weber, E. C., Strizek, B., Gembruch, U., Westerway, S. C., & Dietrich, C. F. (2021) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-021-05972-5 · Cited by 94
“A WFUMB project showed that training midwives in performing routine and focused prenatal scans was a convenient way to cope with the small number of trained sonographers or obstetricians in low-resource countries [17].”
BackgroundEvaluation of antenatal Point-of-Care Ultrasound (PoCUS) training: a systematic review
Bidner, A., Bezak, E., & Parange, N. (2022) · Medical Education Online · doi:10.1080/10872981.2022.2041366 · Cited by 72
“[63] used an asynchronous method, where trainee images and interim report was sent for specialist review while the patient waited.”
BackgroundMethodInfluentialPoint‐of‐care ultrasound in obstetrics
Collins, K., Collins, C., & Kothari, A. (2019) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12133 · Cited by 63
Doig, M., Dizon, J. M. R., Guerrero, K., & Parange, N. (2019) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12138 · Cited by 59
“…alone (10 month period) Kimberly et al. (2009)22 21 midwives 9 weeks OSCE to measure ultrasound ability and skill retention (at 2 months and 6 months) Vinayak et al. (2017)29 Three midwives 4 weeks Agreement between the readings produced by the trainees and the trainers Bentley et al. (2015)26 31…”
Toscano, M. A., Marini, T. J., Drennan, K. J., Baran, T. M., Kan, J. A., Garra, B. S., Dozier, A. M., Ortega, R. L., Quinn, R. A., Zhao, Y., et al. (2021) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-021-03720-w · Cited by 59
A Crossover Comparison of Standard and Telerobotic Approaches to Prenatal Sonography
Adams, S., Burbridge, B., Badea, A., Kanigan, N., Bustamante, L., Babyn, P., & Mendez, I. M. (2018) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14619 · Cited by 51
Karageorgos, G. M., Andreadis, I., Psychas, K., Mourkousis, G., Kiourti, A., Lazzi, G., & Nikita, K. S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2868896 · Cited by 53
Westerway, S. C. (2019) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.12125 · Cited by 42
Bidner, A., Bezak, E., & Parange, N. (2022) · BMC Medical Education · doi:10.1186/s12909-022-03888-5 · Cited by 41
Obstetric ultrasound: where are we and where are we going?
Abramowicz, J. S. (2020) · ULTRASONOGRAPHY · doi:10.14366/usg.20088 · Cited by 40
“It is possible to train non-experts to obtain images and transmit them to the obstetric or radiology department [88].”
BackgroundWong, H. Y., Marcu, L. G., Bezak, E., & Parange, N. (2020) · Risk Management and Healthcare Policy · doi:10.2147/rmhp.s247774 · Cited by 42
Lie, W., Jiang, B., & Zhao, W. (2020) · IEEE Access · doi:10.1109/access.2020.2988563 · Cited by 41
Smith, C. J., Matthias, T., Beam, E. L., Wampler, K., Pounds, L., Nickol, D., Carlson, K., & Michael, K. (2018) · BMC Medical Education · doi:10.1186/s12909-018-1437-2 · Cited by 37
Holmlund, S., Ntaganira, J., Edvardsson, K., Làn, P. T., Sengoma, J. P. S., Kidanto, H. L., Ngarina, M., Small, R. E., & Mogren, I. (2018) · PLoS ONE · doi:10.1371/journal.pone.0208387 · Cited by 37
Luntsi, G., Ugwu, A. C., Ohagwu, C. C., Kalu, O., Sidi, M., & Akpan, E. (2022) · Radiography · doi:10.1016/j.radi.2022.01.003 · Cited by 39
Concepts for point-of-care ultrasound training in low resource settings: a scoping review
Eppel, F., Hunstig, F., Bélard, S., & Kreuels, B. (2025) · The Ultrasound Journal · doi:10.1186/s13089-025-00427-3 · Cited by 38
“[27, 29, 30, 40, 43, 58, 66] Potential bias Trainee selection as potential bias 11 (20.8) [33, 35, 48, 51, 53, 61, 63, 64, 67, 68, 74] Previous ultrasound experience as possible confounder 5 (9.4”
InfluentialVinayak, S., & Brownie, S. M. (2018) · Journal of Interprofessional Care · doi:10.1080/13561820.2018.1470499 · Cited by 31
“Core principles of measurement and evaluation were embedded into every aspect of this initiative with each assessment point fully recorded and evaluated regularly across the project (Vinayak et al., 2017).”
BackgroundMethodSelf-citationDornhofer, K., Farhat, A. M., Guan, K., Parker, E. M., Kong, C., Kim, D., Nguyen, T., Mogi, J., Lahham, S., & Fox, J. C. (2019) · Journal of Clinical Ultrasound · doi:10.1002/jcu.22809 · Cited by 30
“increasing maternal and neonatal health services, of which, screenings with US may be beneficial for identifying high-risk conditions during pregnancy.(17,18) Ultimately, improving the quality of care and knowledge base”
BackgroundHall, E., Matilsky, D. K., Zang, R. M., Hase, N., Ali, A. H., Henwood, P. C., & Dean, A. J. (2021) · The Ultrasound Journal · doi:10.1186/s13089-021-00220-y · Cited by 28
Guideline No. 421: Point of Care Ultrasound in Obstetrics and Gynaecology
Jain, V., O’Quinn, C., & den Hof, M. V. (2021) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2021.07.003 · Cited by 26
Jemal, K., Ayana, D., Tadesse, F., Adefris, M., Awol, M., Tesema, M., Dagne, B., Abeje, S., Bantie, A., Butler, M., et al. (2022) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x221115746 · Cited by 26
“6,8,35,36 For example, a pilot project in Kenya trained midwives to perform basic ultrasound to identify high-risk pregnancies, and used an internet connection through a mobile phone to transmit the acquired images to a main hospital for radiologists to review the images and validate the reports.”
BackgroundLukhele, S., Mulaudzi, F. M., Sepeng, N. V., Netshisaulu, K. G., Ngunyulu, R. N., Musie, M. R., & Anokwuru, R. (2023) · BMC Medical Education · doi:10.1186/s12909-023-04647-w · Cited by 24
“The studies found in this review were conducted across 8 African countries which are Kenya [3, 12], Ethiopia [4], Rwanda [16], Tanzania [7], Ghana [18], Uganda [6, 15, 17], Libe-ria [8] and South Africa [19].”
BackgroundResultInfluentialExperiences of midwives on Vscan limited obstetric ultrasound use: a qualitative exploratory study
Argaw, M. D., Abawollo, H. S., Tsegaye, Z. T., Beshir, I. A., Damte, H. D., Mengesha, B. T., Gebremedhin, Z. K., Heyi, A. F., Guteta, A. A., Mamo, T. T., et al. (2022) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-022-04523-3 · Cited by 23
Viner, A. C., Gadama, G. M., Whyte, S., Kayambo, D., Masamba, M., Makwakwa, E., Lissauer, D. M., Stock, S. J., Norman, J. E., Reynolds, R. M., et al. (2022) · Frontiers in Global Women s Health · doi:10.3389/fgwh.2022.880615 · Cited by 24
“The OSCE approach to “hands-on” assessment is well-established (24, 26, 28, 30, 41), as is the concept of comparing trainee measurements with those obtained by the faculty (20, 22, 23, 33, 42).”
ResultKnights, S., Prasad, S., Kalafat, E., Dadali, A., Sizer, P., Harlow, F. H., & Khalil, A. A. (2023) · PLoS Medicine · doi:10.1371/journal.pmed.1004192 · Cited by 23
“Most of the data on the use of POCUS in antenatal settings are from low-resource settings where there is inadequate access to ultrasound owing to both material and physical constraints; hence, the focus is on task-shifting of obstetric ultrasound from sonographers to primary care providers [19,20].”
BackgroundWhittington, J. R., Hughes, D. S., Rabie, N. Z., Ounpraseuth, S., Nembhard, W. N., Chauhan, S. P., & Magann, E. F. (2021) · American Journal of Perinatology · doi:10.1055/s-0041-1739352 · Cited by 21
Kariman, S. S., van den Heuvel, J. F. M., Adriaanse, B. M. E., Oepkes, D., & Bekker, M. N. (2024) · Prenatal Diagnosis · doi:10.1002/pd.6679 · Cited by 20
Bidner, A., Bezak, E., & Parange, N. (2023) · BMC Public Health · doi:10.1186/s12889-023-17106-4 · Cited by 18
“The use of ultrasound in low-resource settings has been shown to increase attendance at antenatal care appointments and parental engagement with pregnancy care [45–47], and was described by respondents to this survey.”
BackgroundMatiang’i, M., Joosse, K., Ngunju, P., Kiilu, C., Romy, H., Hangelbroek, M., & Omogi, J. O. (2021) · Open Journal of Clinical Diagnostics · doi:10.4236/ojcd.2021.111001 · Cited by 17
“Training of midwives on how to perform basic obstetric ultrasound screening is very critical and valuable enabler; though based in the Nairobi metropolis, findings from a related study at the Agakhan University Hospital [17] established a higher competency rating with an accuracy of 99.63% among the midwives who had b…”
BackgroundInfluentialAbawollo, H. S., Argaw, M. D., Tsegaye, Z. T., Beshir, I. A., Guteta, A. A., Heyi, A. F., Mengesha, B. T., Mamo, T. T., Gebremedhin, Z. K., Damte, H. D., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0281626 · Cited by 15
Obstetric ultrasound training programmes for midwives: A scoping review
Casmod, Y., & Armstrong, S. J. (2023) · Health SA Gesondheid · doi:10.4102/hsag.v28i0.2163 · Cited by 12
“Obstetric ultrasound, a significant component of antenatal care, is a non-invasive imaging modality (Dornhofer et al. 2020) that has been identified as an important and valuable tool used routinely in pregnancy (Vinayak et al. 2017).”
BackgroundMethodInfluentialEvaluation of a Point-of-Care Ultrasound Educational Program for Nurse Educators
Matsumoto, M., Tamai, N., Miura, Y., Okawa, Y., Yoshida, M., Igawa, Y., Nakagami, G., & Sanada, H. (2021) · The Journal of Continuing Education in Nursing · doi:10.3928/00220124-20210714-07 · Cited by 12
Smith, C. J., Matthias, T., Beam, E. L., Wampler, K., Pounds, L., Nickol, D., Shope, R. J., Carlson, K., & Michael, K. (2020) · Journal of General Internal Medicine · doi:10.1007/s11606-020-06105-5 · Cited by 11
Eggleston, A. J., Farrington, E., McDonald, S. J., & Aziz, S. (2022) · BMJ Open · doi:10.1136/bmjopen-2022-065181 · Cited by 12
Pioneering point-of-care obstetric ultrasound integration in midwifery education – the MEPOCUS study
Groos, J., Walter, A., Plöger, R., Strizek, B., Gembruch, U., Wittek, A., & Recker, F. (2024) · BMC Medical Education · doi:10.1186/s12909-024-06221-4 · Cited by 10
“Our project targets midwives in training and integrates seamlessly into their curriculum, unlike most studies that include practising midwives, often leading to conflicts with their professional responsibilities [9, 25].”
BackgroundGraham, K. P., Colquhoun, S., LaBond, C., Housen, T., Mohale, H., Campbell, S., & Sweet, L. P. (2025) · Women and Birth · doi:10.1016/j.wombi.2024.101866 · Cited by 10
Beldjerd, M., Lafouge, A., Giorgi, R., Corroller, A. L., & Quarello, E. (2022) · PLoS ONE · doi:10.1371/journal.pone.0269477 · Cited by 10
ISUOG Practice Guidelines: point‐of‐care ultrasound in obstetrics and gynecology
Robertis, V. D., Bilardo, C. M., Abu-Rustum, R., Poon, L. C., Kamel, R., Rocha, R. M., Syngelaki, A., Stampalija, T., & Collaborators (2025) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.70122 · Cited by 9
Groos, J., Walter, A., Wittek, A., Strizek, B., Gembruch, U., & Recker, F. (2024) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-024-07558-3 · Cited by 9
“This period, typically ranging from 3 to 6 months, represents a crucial phase of workplace-based learning [14, 17, 18].”
BackgroundInfluentialUse of ultrasound and mHealth to improve perinatal outcomes in low and middle income countries
Swanson, J. O., Nathan, R., Swanson, D. L., Perez, K., Bresnahan, B. W., Mirza, W. A., & Goldenberg, R. L. (2019) · Seminars in Perinatology · doi:10.1053/j.semperi.2019.03.016 · Cited by 10
A Curriculum Model for Multidisciplinary Training of Midwife Sonographers in a Low Resource Setting
Vinayak, S., Temmerman, M., Villeirs, G. M., & Brownie, S. M. (2021) · Journal of Multidisciplinary Healthcare · doi:10.2147/jmdh.s331371 · Cited by 8
Self-citationMessina, M. P., Piccioni, M. G., Petrella, C., Vitali, M., Greco, A., Ralli, M., Ceccanti, M., Ferraguti, G., Neri, I., Ricchi, A., et al. (2021) · Minerva Obstetrics and Gynecology · doi:10.23736/s2724-606x.21.04687-6 · Cited by 8
Lynch, K. A., Atkinson, T. M., Omisore, A. D., Famurewa, O. C., Olasehinde, O. O., Odujoko, O. O., Alatise, O. I., Egberongbe, A. A., Kingham, T. P., Morris, E. A., et al. (2022) · JMIR Formative Research · doi:10.2196/34035 · Cited by 7
“The device proposed for use in this intervention was developed in the United States (Philips Ultrasound Inc, Bothell, WA) but has been successfully used by midwives at Aga Khan hospital in Nairobi, Kenya [11].”
MethodMubuuke, A. G., & Nassanga, R. (2023) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-023-05429-4 · Cited by 7
“POCUS refers to the practice of other health professionals who are not imaging experts using ultrasound to diagnose basic emergency cases without waiting for a qualified imaging professional [3].”
BackgroundMidwives' experiences of performing obstetric ultrasounds in maternity care: a systematic review
Bwanga, O., Mwase, G., & Kaunda, H. C. (2021) · African Journal of Midwifery and Women s Health · doi:10.12968/ajmw.2020.0033 · Cited by 7
Kumar, M. B., Mulongo, C. M., Pincerato, L., Vita, M. V. D., Saidi, S., Gakii, Y., Morino, G., & Kumar, P. A. (2024) · Oxford Open Digital Health · doi:10.1093/oodh/oqae037 · Cited by 6
“…broadly felt that the nurse-led, point-of-care obstetric ultrasonography was useful in improving access to an important diagnostic tool in obstetrics, and in reducing the cost of ultrasonography–a broadly accepted view from other studies of point-of-care ultrasonography in LMICs [17, 34, 35].”
Matiang’i, M., Ngunju, P., Nyagero, J. M., & Omogi, J. O. (2020) · Open Journal of Clinical Diagnostics · doi:10.4236/ojcd.2020.102006 · Cited by 6
“There is evidence that midwives can learn basic ultrasound skills [5] [6] and such diagnostic care is not only beneficial but also leaves pregnant women more satisfied when they know early enough the status of their pregnancy [7].”
BackgroundLynch, K. A., Omisore, A. D., Famurewa, O. C., Olasehinde, O. O., Odujoko, O. O., Vera, J. A., Kingham, T. P., Alatise, O. I., Egberongbe, A. A., Morris, E. A., et al. (2021) · International Journal of Qualitative Methods · doi:10.1177/16094069211002421 · Cited by 7
“This device was developed in the United States (Philips Ultra-sound, Inc., Bothell, WA, USA) but has been successfully used by midwives at Aga Khan hospital in Nairobi, Kenya (Vinayak et al., 2017).”
Johnston, B. K., Darling, E., Malott, A. M., Thomas, L., & Murray‐Davis, B. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e27512 · Cited by 6
“This has also been identified by other authors, with one study reporting that 100% of pregnant patients felt safe with POCUS being used in their care [3].”
BackgroundResultInfluentialTeaching obstetric ultrasound at Mulago Hospital - Kampala, Uganda
Ahmadzia, H. K., Cigna, S. T., Namagembe, I., Macri, C. J., Galerneau, F., & Magriples, U. (2018) · African Health Sciences · doi:10.4314/ahs.v18i1.21 · Cited by 6
Twelve tips for point-of-care ultrasound teaching in low-resource settings
Davis, N. R., & Alade, K. H. (2020) · Medical Teacher · doi:10.1080/0142159x.2020.1845307 · Cited by 6
“In a Kenyan study funded by Phillips, Vinayak et al. (2017) utilized Philips Connected Care, a connectivity app, and a cellphone modem to allow real-time transmission and image review/ verification in obstetric ultrasounds for a small group of midwives.”
BackgroundMethodViner, A. C., Okolo, I. D., Norman, J. E., Stock, S. J., & Reynolds, R. M. (2022) · Frontiers in Global Women s Health · doi:10.3389/fgwh.2022.854198 · Cited by 6
“The remainder (n = 14, 56%) (27, 31, 35, 37, 40–48, 53) undertook some form of assessment ranging from written tests (n= 9, 64%) (27, 31, 35, 37, 40, 42, 44, 47, 48), to supervised practical exams (n= 12, 86%) (31, 35, 37, 41–48, 53) or a combination of both (n = 7, 50%) (31, 35, 37, 42, 44, 47, 48).”
Terefe, F. T., Yang, B., Jemal, K., Ayana, D., Adefris, M., Awol, M., Tesema, M., Dagne, B., Abeje, S., Bantie, A., et al. (2024) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2024.0066 · Cited by 5
“35 This study showed significant success as there was a high rate of concordance between midwives and radiologist reports, with the midwives ’ accuracy at 99.63%.”
InfluentialLi, Y., Wang, H., Yuan, K., Zhou, X., Wang, M., Huang, Y., Yu, X., & Tang, K. (2025) · The Ultrasound Journal · doi:10.1186/s13089-025-00471-z · Cited by 7
Dayan, R. R., Karni, O., Shitrit, I. B., Gaufberg, R., Ilan, K., & Fuchs, L. (2025) · Perspectives on Medical Education · doi:10.5334/pme.1613 · Cited by 5
Review of Teleradiology Applications in Some Selected African CountriesPreprint
Nortey, J. N. N., Agbotsigah, L. A., Osei, E. O., Adabo, A., Gborgblah, M., & Suleiman, R. (2023) · medRxiv · doi:10.1101/2023.10.07.23296691 · Cited by 8
Haluzani, S., Lungu, A., Mudenda, M., Hamapa, A. M., Mkandawire, C., Kaluba, A., Khondowe, O., Mutale, M., Imasiku, K., Nyirenda, M., et al. (2024) · WFUMB Ultrasound Open · doi:10.1016/j.wfumbo.2024.100057 · Cited by 4
Sesay, A. D. D., Koroma, A. L., van der Kwaak, A., Seguin, E., Kanu, A. F., Falama, A. M., Bakker, M. I., & de Vries, I. (2026) · BMC Pregnancy and Childbirth · doi:10.1186/s12884-026-09152-8 · Cited by 4
“Similar studies show that targeted training enables individuals with no prior ultrasound experience to conduct basic obstetric scans effectively [27–33].”
Nurse performed bladder ultrasound: a clinical quality improvement initiative
Liptrott, S. J., Saliquni, A., Giau, L., Pecora, R., Cimino, C., Piccolo, A. L., Palermo, A., Vidovic, B., Cheda, E., Imhof, S. A., et al. (2024) · Contemporary Nurse · doi:10.1080/10376178.2024.2406350 · Cited by 4
“Nurses can contribute significantly to procedural care of patients, in fact the performance of ultrasound following advanced certification is a recognised nursing procedure in patient care including lung and obstetric ultrasound (Santos et al., 2018; Vinayak et al., 2017).”
Beldjerd, M., Quarello, E., Lafouge, A., Giorgi, R., & Corroller, A. L. (2023) · Journal of Telemedicine and Telecare · doi:10.1177/1357633x231151713 · Cited by 3
“9,10 ASTE does not require the simultaneous real-time availability of healthcare professionals or of the patient.”
Sousa, M. F., & Corning-Davis, B. (2019) · Journal of Radiology Nursing · doi:10.1016/j.jradnu.2019.03.002 · Cited by 3
Bo, X., Sun, L., Wan, J., Sun, Y.-K., Zhang, Y., He, T., Qian, Z.-B., Qin, C., Guo, L., & Xu, H. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103738 · Cited by 3
Rolin, J., Corini, E., Michel, J., Hossu, G., Gauchotte, E., Germain, J., Morel, O., & Ambroise-Grandjean, G. (2022) · Pédagogie médicale · doi:10.1051/pmed/2022010 · Cited by 3
Tung, J. Y., Gower, S., Ooteghem, K. V., Nouredanesh, M., & Gage, W. H. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818914-6.00008-9 · Cited by 2
Joe, W., Prakash, A., Ahluwalia, K., Kim, R., & Subramanian, S. V. (2025) · Journal of Global Health · doi:10.7189/jogh.15.04136 · Cited by 2
“Line-listing of twin pregnancies, tracking, and review of such pregnancies and their outcomes through dedicated platforms is also necessary [ 39 ].”
Directive clinique no 421 : Échographie au chevet en obstétrique et gynécologie
Jain, V., O’Quinn, C., & den Hof, M. V. (2021) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2021.07.004 · Cited by 2
Johnston, B. K., Darling, E., Malott, A. M., Kras, S., Bernacci, C., Thomas, L., & Murray‐Davis, B. (2022) · MedEdPublish · doi:10.12688/mep.19361.2 · Cited by 2
Devi, D. A., Hanifah, L., Prihatiningsih, A. D., & Astuti, A. W. (2022) · Jurnal Aisyah Jurnal Ilmu Kesehatan · doi:10.30604/jika.v7i4.1283 · Cited by 2
Doig, M., Guerrero, K., Dizon, J. M. R., & Parange, N. (2019) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.07.298 · Cited by 2
Johnston, B. K., Darling, E., Malott, A. M., Thomas, L., & Murray‐Davis, B. (2023) · Canadian Journal of Midwifery Research and Practice · doi:10.22374/cjmrp.v22i2.14 · Cited by 2
Digital Health and Entrepreneurship in Primary Health Care Settings – Kenya's ExperiencePreprint
Matiangi, M. O., Matiangi, M. O., Ngunju, P. W., Koen, J., Kiilu, C., Romy, H., Aranka, H., Hangelbroek, M., & Ndoria, S. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4073451 · Cited by 2
Eppel, F., Hunstig, F., Kreuels, B., & Bélard, S. (2026) · The Ultrasound Journal · doi:10.5826/tuj.2026.18295 · Cited by 1
Hampshire, Z., Wood, L., Schubert, C., Dizon, J. M., Guerrero, K., & Parange, N. (2026) · Australasian Journal of Ultrasound in Medicine · doi:10.1002/ajum.70040 · Cited by 1
“Implementation of such services is a major economic consideration in low-income countries, and the cost of PoCUS is only deemed appropriate if comparable outcomes are met with current ANC examinations at a lower expense [27].”
InfluentialIndependent learning of the sonographic FAST exam technique using a tablet-based training module
Leavitt, D. R. M., Arpin, P. A., Nielsen, B. M., & Mason, N. L. (2021) · American Journal of Disaster Medicine · doi:10.5055/ajdm.2021.0392 · Cited by 1
Johnston, B. K., Darling, E., Malott, A. M., Kras, S., Bernacci, C., Thomas, L., & Murray‐Davis, B. (2025) · MedEdPublish · doi:10.12688/mep.19361.3 · Cited by 1
“Many use POCUS to aid in clinical assessments such as pregnancy dating and confirming fetal presentation (Bentley et al ., 2015; Edvardsson et al ., 2016; Kimberly et al ., 2010; Vinayak & Brownie, 2018; Vinayak et al ., 2017).”
Bozhkov, V., Madjov, R., Plachkov, I., Arnaudov, P., Chernopolsky, P., & Krasnaliev, I. (2014) · Scripta Scientifica Medica · doi:10.14748/ssm.v46i2.687
Maternal-Fetal and Women’s Imaging for Global Health Radiology
Dowdy, D. L., & Omofoye, T. S. (2019) · Springer eBooks · doi:10.1007/978-3-319-98485-8_19
Stadler, J. A. M. (2019) · Open University of Cape Town (University of Cape Town)
Ebelik Mesleğinin Yeni Gelişen Rolü: Obsetrik Ultrason Muayenesi
Sökmen, Y., & TAŞPINAR, A. (2020) · Mersin Üniversitesi Tıp Fakültesi Lokman Hekim Tıp Tarihi ve Folklorik Tıp Dergisi · doi:10.31020/mutftd.707209
Improving access to ultrasound imaging in northern, remote communities
Adams, S. (2021) · HARVEST (University of Saskatchewan)
Viability of Point of Care Ultrasound Screening in Primary Health Care Setting_KenyaPreprint
Matiangi, M. O., Ngunju, P. W., Koen, J., Kiilu, C., Romy, H., Aranka, H., Hangelbroek, M., Opanga, Y., & Ndoria, S. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4153423
Sabir, M., Aster, R., Rafiq, R., Raza, M. A., Alam, M. A., & Alloudin, A. (2023) · Pakistan Journal of Health Sciences · doi:10.54393/pjhs.v4i12.1222
Utilidad de la capacitación en ecografía a los obstetras o matronas: una revisión sistemática
Enrique-Peves, N. X., Quinto-Aylas, W. A., Ordoñez-Vargas, C. I., & Vega-Gonzales, E. O. (2025) · Investigación en Educación Médica · doi:10.22201/fm.20075057e.2025.54.24613
“Además, se ha encontrado que, en el 90% de los casos las matronas pudieron identificar a pacientes de alto riesgo para su oportuna derivación 59 .”
InfluentialShoukat, S. (2025) · Journal of Gandhara Medical and Dental Science · doi:10.37762/jgmds.12-2.687
Point-of-Care-Ultraschall in Geburtshilfe und Gynäkologie
Recker, F. (2025) · Springer eBooks · doi:10.1007/978-3-662-67373-7_39
Quinton, A. E., Russo, K., Alphonse, J., & Lanzarone, V. (2025) · Sonography · doi:10.1002/sono.12526
Utilisation of Obstetric Ultrasound at the Ho Teaching Hospital in Ghana
Angmorterh, S. K., Suraka, S. A., Dzefi‐Tettey, K., Kekessie, K. K., Angaag, N. A., Agyemang, P. N., & Kenyanya, J. (2025) · South African Radiographer · doi:10.54450/saradio.2025.63.1.829
Maternal-Fetal Imaging in Global Health Radiology
Dowdy, D. L., Ostrem-Niemcewicz, K., & Omofoye, T. S. (2025) · Springer eBooks · doi:10.1007/978-3-031-86485-8_20
Argaw, M. D., Abawollo, H. S., Tsegaye, Z. T., Beshir, I. A., Damte, H. D., Mengesha, B. T., Gebremedhin, Z. K., Heyi, A. F., Guteta, A. A., Mamo, T. T., et al. (2022) · Figshare · doi:10.6084/m9.figshare.19343053
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26641648
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26641627
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26558510
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26558519
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26558501
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26558507
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26641678
Bidner, A., Bezak, E., & Parange, N. (2024) · Figshare · doi:10.6084/m9.figshare.26641624
Metadata
- Authors
- Vinayak, S., Sande, J., Nisenbaum, H., & Nolsøe, C. P.
- Affiliations
- Aga Khan University Hospital Nairobi (KE)
- Penn Presbyterian Medical Center (US)
- University of Copenhagen (DK)
- Corresponding author
- Vinayak, Sudhir
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 43
- Issue
- 10
- Pages
- 2125-2132
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W2735074909
- Cited by
- 123
- References
- 15
- Citations by year
- 2026: 5 · 2025: 10 · 2024: 39 · 2023: 11 · 2022: 19 · 2021: 15 · 2020: 7 · 2019: 9 · 2018: 7
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor)
- Locations
- Ultrasound in Medicine & Biology (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Research at the University of Copenhagen (University of Copenhagen) (publishedVersion, cc-by-nc-nd)
- eCommons - AKU (Aga Khan University) (submittedVersion)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- point-of-care ultrasound, midwifery education, rural health care, teleradiology, high-risk pregnancy identification, telemedicine, developing countries
- MeSH terms
- Female, Humans, Kenya, Midwifery, Pilot Projects, Pregnancy, Ultrasonography, Point-of-Care Systems, Cell Phone, Rural Nursing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.

