Ultrasound Contrast Agent Modeling: A Review
Open accessThe DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.
Abstract
Ultrasound is extensively used in medical imaging, being safe and inexpensive and operating in real time. Its scope of applications has been widely broadened by the use of ultrasound contrast agents (UCAs) in the form of microscopic bubbles coated by a biocompatible shell. Their increased use has motivated a large amount of research to understand and characterize their physical properties as well as their interaction with the ultrasound field and their surrounding environment. Here we review the theoretical models that have been proposed to study and predict the behavior of UCAs. We begin with a brief introduction on the development of UCAs. We then present the basics of free-gas-bubble dynamics upon which UCA modeling is based. We review extensively the linear and non-linear models for shell elasticity and viscosity and present models for non-spherical and asymmetric bubble oscillations, especially in the presence of surrounding walls or tissue. Then, higher-order effects such as microstreaming, shedding and acoustic radiation forces are considered. We conclude this review with promising directions for the modeling and development of novel agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review
Maeda, H., Wu, J., Sawa, T., Matsumura, Y., & Hori, K. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00248-5 · Cited by 6,565
Rheology: Principles, Measurements, and Applications
Macosko, C. W. (1994) · Cited by 3,474
VIII. On the pressure developed in a liquid during the collapse of a spherical cavity
Rayleigh, L. (1917) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440808635681 · Cited by 3,263
Leighton, T. G. (2012) · Cited by 2,284
On the Stability of Gas Bubbles in Liquid-Gas Solutions
Epstein, P. S., & Plesset, M. S. (1950) · The Journal of Chemical Physics · doi:10.1063/1.1747520 · Cited by 1,634
Bubble oscillations of large amplitude
Keller, J. B., & Miksis, M. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384720 · Cited by 1,346
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Collapse of an initially spherical vapour cavity in the neighbourhood of a solid boundary
Plesset, M. S., & Chapman, R. B. (1971) · Journal of Fluid Mechanics · doi:10.1017/s0022112071001058 · Cited by 1,082
Statistical theory of superlattices
Bethe, H. A. (1935) · Proceedings of the Royal Society of London. Series A - Mathematical and Physical Sciences · doi:10.1098/rspa.1935.0122 · Cited by 1,069
Single-bubble sonoluminescence
Brenner, M. P., Hilgenfeldt, S., & Lohse, D. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.425 · Cited by 1,052
Cited by
Stimuli-responsive nanobubbles for biomedical applications
Xiong, R., Xu, R. X., Huang, C., De Smedt, S., & Braeckmans, K. (2021) · Chemical Society Reviews · doi:10.1039/c9cs00839j · Cited by 236
Opening doors with ultrasound and microbubbles: Beating biological barriers to promote drug delivery
Deprez, J., Lajoinie, G., Engelen, Y., De Smedt, S. C., & Lentacker, I. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.02.015 · Cited by 207
Self-citationWang, Y., Lu, H., Huang, L., Li, D., Qiu, W., Li, L., Xu, G., Su, M., Zhou, J., & Li, F. (2023) · Biosensors · doi:10.3390/bios13050528 · Cited by 13
Metadata
- Authors
- Versluis, M., Stride, E., Lajoinie, G., Dollet, B., & Segers, T.
- Venue
- Ultrasound in Medicine & Biology
- Publisher
- Elsevier BV
- Published
- 2020-09
- Volume
- 46
- Issue
- 9
- Pages
- 2117-2144
- ISSN
- 0301-5629 (ISSN-L)
- OpenAlex
- W3035568990
- Cited by
- 233
- References
- 117
- FWCI
- 8.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.