CoChat

Sono-chemical treatment of per- and poly-fluoroalkyl compounds in aqueous film-forming foams by use of a large-scale multi-transducer dual-frequency based acoustic reactor

Open access
Gole, Vitthal L., Sierra-Alvarez, Reyes, Peng, Hui, Giesy, John P., Deymier, Pierre, Keswani, Manish · 2018 · Ultrasonics Sonochemistry
Cited by 80

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Aqueous film-forming foams (AFFFs) contain a mixture of organic chemicals, including per- and poly-fluorinated, alkyl sulfonate substances (PFAS) (1-5%, w/w). Some longer-chain PFAS can be toxic, moderately bioaccumulative and persistent in the environment. In the present work, decomposition of PFAS present in two commercially available AFFFs (ANSUL- and 3M-) was investigated using a sono-chemical reactor of volume 91 L. The reactor consists of 12 transducers with operating frequencies of 1 MHz or 500 kHz and total input power of 12 kW. Degradation of PFASs performed using various dilutions of AFFF revealed that release of F- and SO4-2 ions was inversely proportional to initial pH of up to 4. Defluorination of ANSUL-AFFF resulted in an increase in the concentration of F- released from 55.6 ± 0.3 µM (500× dilution) to 58.6 ± 0.6 (25× dilution), while for 3M AFFF it increased from 19.9 ± 0.7 µM (500× dilution) to 217.1 ± 2.4 µM (25× dilution). Though amounts of F- released were less for ANSUL-AFFF than for 3M-AFFF, there was a considerable increase in removal of TOC and release of SO4-2 present in ANSUL-AFFF. Approximately 90.5% and 26.6% reduction of perfluoroalkyl sulfonates (PFSA) and perfluoroalkyl carboxylates (PFCA) in 3M, respectively, and 38.4% reduction of fluorotelomer sulfonates in ANSUL-AFFF were achieved in 13 h. Estimated costs of energy for the treatment of ANSUL-AFFF and 3M-AFFF at a 500× dilution were $0.015 ± 0.0001/L and $0.019 ± 0.0002/L, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultsonch.2018.02.014

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 80

Metadata

Authors
Gole, V. L., Sierra-Alvarez, R., Peng, H., Giesy, J. P., Deymier, P., & Keswani, M.
Venue
Ultrasonics Sonochemistry
Publisher
Elsevier BV
Published
2018-07
Volume
45
Pages
213-222
ISSN
1350-4177 (ISSN-L)
OpenAlex
W2793696147
Cited by
80
References
4
FWCI
2.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sono-chemical treatment of per- and poly-fluoroalkyl compounds in aqueous film-forming foams by use of a large-scale multi-transducer dual-frequency based acoustic reactor. https://app.cochat.ai/papers/10.1016/j.ultsonch.2018.02.014
The paper
Gole, V. L., Sierra-Alvarez, R., Peng, H., Giesy, J. P., Deymier, P., & Keswani, M. (2018). Sono-chemical treatment of per- and poly-fluoroalkyl compounds in aqueous film-forming foams by use of a large-scale multi-transducer dual-frequency based acoustic reactor. Ultrasonics Sonochemistry. https://doi.org/10.1016/j.ultsonch.2018.02.014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.