Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

High-intensity ultrasound: A novel technology for the development of probiotic and prebiotic dairy products

Open access
Guimarães, Jonas T., Balthazar, Celso F., Scudino, Hugo, Pimentel, Tatiana C., Esmerino, Erick A., Ashokkumar, Muthupandian, Freitas, Monica Q., Cruz, Adriano G. · 2019 · Ultrasonics Sonochemistry

Abstract

High-intensity ultrasound (HIUS) can be used as a mild-preservation technology in dairy products, due to its ability to inactivate pathogenic microorganisms and enzymes. In addition, it can result in physical and chemical alterations in the products and has impact on the probiotic viability and metabolic activity. This review provides an overview of the effects of HIUS on dairy products manufactured with probiotics and prebiotics. Furthermore, it presents perspectives of HIUS application on paraprobiotics and postbiotics products. HIUS has been proven to be a potential technology and its application to fermented dairy products can result in shorter processing time, increased probiotic viability, and products with low lactose content, higher oligosaccharides concentration, less undesirable taste (lower propionic and acetic acids content) and reduced ingredients (no need of prebiotic addition or β-galactosidase inclusion). In cheeses, HIUS can reduce the ripening time and accelerate proteolysis, resulting in products with better sensory, textural and nutritional (bioactive peptides) characteristics. Furthermore, it can change the prebiotic structure, facilitating the access for the probiotics. The impact of the HIUS is highly dependent on the process parameters (frequency, power, processing time, pulse mode and duration), type of probiotic culture and food composition. Therefore, HIUS process parameters must be precisely quantified and controlled. The HIUS can also be applied to the inactivation of probiotic cultures and development of paraprobiotic products or to the improvement in the production of soluble factors (postbiotics) with health effects. Further researches should be conducted to evaluate the efficiency of this methodology in the cases of paraprobiotic and postbiotic products.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultsonch.2019.05.004

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 158

Metadata

Authors
Guimarães, J. T., Balthazar, C. F., Scudino, H., Pimentel, T. C., Esmerino, E. A., Ashokkumar, M., Freitas, M. Q., & Cruz, A. G.
Venue
Ultrasonics Sonochemistry
Publisher
Elsevier BV
Published
2019-10
Volume
57
Pages
12-21
ISSN
1350-4177 (ISSN-L)
OpenAlex
W2944699073
Cited by
158
References
4
FWCI
10.73
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-intensity ultrasound: A novel technology for the development of probiotic and prebiotic dairy products. https://app.cochat.ai/papers/10.1016/j.ultsonch.2019.05.004
The paper
Guimarães, J. T., Balthazar, C. F., Scudino, H., Pimentel, T. C., Esmerino, E. A., Ashokkumar, M., Freitas, M. Q., & Cruz, A. G. (2019). High-intensity ultrasound: A novel technology for the development of probiotic and prebiotic dairy products. Ultrasonics Sonochemistry. https://doi.org/10.1016/j.ultsonch.2019.05.004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.