CoChat

Modeling of process intensification of biodiesel production from Aegle Marmelos Correa seed oil using microreactor assisted with ultrasonic mixing

Open access
Thangarasu, Vinoth, Siddharth, R., Ramanathan, Anand · 2020 · Ultrasonics Sonochemistry
Cited by 67

The DOI matches its Crossref record.

Abstract

Conventionally, the batch type reactors were used for the production of biodiesel. However, in recent years, the usage of microreactors has started emerging as a significant substitute for biodiesel production due to its higher conversion rate at a short duration. These microreactors have a significantly high surface to volume ratio and high heat-mass transfer rate. The disadvantage of this type of reactors is its low mixing rate of the reagents. This can be overcome with the assistance of ultrasonic mixing. The main objective of this paper is to study the interlaced effect of a continuous flow microreactor and ultrasonic mixing on trans-esterification of Aegle Marmelos Correa seed oil using sodium methoxide catalyst. Results of microreactors with 0.3 mm and 0.8 mm diameter were compared. The effects of process parameters namely, flow rate (2–10 mL/min), reaction temperature (45–65 °C), catalyst amount (0.5–2.5 wt%), oil to methanol molar ratio (1:6–1:18) and ultrasonic mixing time (30–150 s) were studied using response surface methodology (RSM). The biodiesel yield of 98% and 91.8% were obtained for 0.3 mm and 0.8 mm microreactors, respectively. The maximum biodiesel yield observed in 0.3 mm reactor under following optimum conditions: 6.8 mL/min flow rate, 48 °C reaction temperature, 1.3 wt% catalyst, 1:9 oil to methanol molar ratio and 83 s ultrasonic mixing time. The predictive and generalization abilities of RSM and artificial neural network (ANN) models were evaluated and compared. The study showed that ANN and RSM models could predict the yield with an R2 value of 0.9955 and 0.9900 respectively. However, the ANN model predicted the yield with the least mean square error value of 0.00001294, which is much lower than RSM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ultsonch.2019.104764

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 67

Metadata

Authors
Thangarasu, V., Siddharth, R., & Ramanathan, A.
Venue
Ultrasonics Sonochemistry
Publisher
Elsevier BV
Published
2020-01
Volume
60
Pages
104764
ISSN
1350-4177 (ISSN-L)
OpenAlex
W2971876484
Cited by
67
References
0
FWCI
2.65
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modeling of process intensification of biodiesel production from Aegle Marmelos Correa seed oil using microreactor assisted with ultrasonic mixing. https://app.cochat.ai/papers/10.1016/j.ultsonch.2019.104764
The paper
Thangarasu, V., Siddharth, R., & Ramanathan, A. (2020). Modeling of process intensification of biodiesel production from Aegle Marmelos Correa seed oil using microreactor assisted with ultrasonic mixing. Ultrasonics Sonochemistry. https://doi.org/10.1016/j.ultsonch.2019.104764

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.