Echographic measurement of skin thickness in adults by high frequency ultrasound to assess the appropriate microneedle length for intradermal delivery of vaccines
Abstract
Skin thickness (epidermis-dermis) across the deltoid, suprascapular, waist and thigh as possible body sites for a new microdelivery system for intradermal (id) inoculation were evaluated using 20 MHz ultrasound echography in 205 women and 137 men aged 18-70 years, in three ethnic groups: Caucasian, Asian and Black. Mean skin thickness was 2.54 mm at the suprascapular, 2.02 mm at the deltoid, 1.91 mm at the waist and 1.55 mm at the thigh. A 1.5 mm microneedle length inserted perpendicularly to the skin surface would ensure the administration of the antigen into the dermal layer, irrespectively of subject gender, age, ethnicity and BMI. The deltoid, suprascapular and waist are the most appropriate body sites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Once adolescence is reached, skin is known to thin as age increases.
“Once adolescence is reached, skin is known to thin as age increases [70,80,81,82].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [81]
The citation lists haven’t been fetched yet
References 43 · Cited by 235
- Authors
- Laurent, A., Mistretta, F., Bottigioli, D., Dahel, K., Goujon, C., Nicolas, J. F., Hennino, A., & Laurent, P. E.
- Affiliations
- Hôpital Lyon Sud (FR)
- Hospices Civils de Lyon (FR)
- Lyon 1 Université (FR)
- Becton Dickinson (France) (FR)
- Corresponding author
- Laurent, Philippe E.
- Venue
- Vaccine
- Publisher
- Elsevier BV
- Published
- 2007-08
- Volume
- 25
- Issue
- 34
- Pages
- 6423-6430
- ISSN
- 0264-410X (ISSN-L)
- OpenAlex
- W1992894246
- Cited by
- 235
- References
- 43
- Citations by year
- 2026: 4 · 2025: 10 · 2024: 10 · 2023: 9 · 2022: 15 · 2021: 16 · 2020: 16 · 2019: 17 · 2018: 14 · 2017: 11 · 2016: 12 · 2015: 18 · 2014: 12 · 2013: 11 · 2012: 16
- FWCI
- 8.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Vaccine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmaceutical Science › Advancements in Transdermal Drug Delivery
- Health Sciences › Medicine › Emergency Medicine › Intramuscular injections and effects
- Health Sciences › Medicine › Dermatology › Dermatologic Treatments and Research
- Keywords
- skin thickness, microneedles, intradermal vaccination, ultrasonography, deltoid muscle, waist, thigh, injection site selection, ethnic differences, body mass index
- MeSH terms
- Administration, Cutaneous, Adolescent, Adult, Aged, Female, Humans, Male, Middle Aged, Needles, Skin, Ultrasonography, Vaccines, Body Mass Index
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review