Electric field standing wave effects in FT-IR transflection spectra of biological tissue sections: Simulated models of experimental variability
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The so-called electric field standing wave effect (EFSW) has recently been demonstrated to significantly distort FT-IR spectra acquired in a transflection mode, both experimentally and in simulated models, bringing into question the appropriateness of the technique for sample characterization, particularly in the field of spectroscopy of biological materials. The predicted effects are most notable in the regime where the sample thickness is comparable to the source wavelength. In this work, the model is extended to sample thicknesses more representative of biological tissue sections and to include typical experimental factors which are demonstrated to reduce the predicted effects. These include integration over the range of incidence angles, varying degrees of coherence of the source and inhomogeneities in sample thickness. The latter was found to have the strongest effect on the spectral distortions and, with inhomogeneities as low as 10% of the sample thickness, the predicted distortions due to the standing wave effect are almost completely averaged out. As the majority of samples for biospectroscopy are prepared by cutting a cross section of tissue resulting in a high degree of thickness variation, this finding suggests that the standing wave effect should be a minor distortion in FT-IR spectroscopy of tissues. The study has important implications not only in optimization of protocols for future studies, but notably for the validity of the extensive studies which have been performed to date on tissue samples in the transflection geometry.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bassan, P., Kohler, A., Martens, H., Lee, J., Byrne, H. J., Dumas, P., Gazi, E., Brown, M., Clarke, N., & Gardner, P. (2010) · The Analyst · doi:10.1039/b921056c · Cited by 375
Self-citationElectric field standing wave artefacts in FTIR micro-spectroscopy of biological materials
Filik, J., Frogley, M. D., Pijanka, J. K., Wehbe, K., & Cinque, G. (2012) · The Analyst · doi:10.1039/c2an15995c · Cited by 122
The effect of optical substrates on micro-FTIR analysis of single mammalian cells
Wehbe, K., Filik, J., Frogley, M. D., & Cinque, G. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6521-6 · Cited by 67
Cited by
Lewy pathology in Parkinson’s disease consists of crowded organelles and lipid membranes
Shahmoradian, S. H., Lewis, A. J., Genoud, C., Hench, J., Moors, T. E., Navarro, P. P., Castaño-Díez, D., Schweighauser, G., Graff-Meyer, A., Goldie, K. N., et al. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0423-2 · Cited by 996
Spectral pre and post processing for infrared and Raman spectroscopy of biological tissues and cells
Byrne, H. J., Knief, P., Keating, M. E., & Bonnier, F. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00440c · Cited by 213
Self-citationThe electric field standing wave effect in infrared transflection spectroscopy
Mayerhöfer, T. G., & Popp, J. (2018) · Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2017.10.033 · Cited by 55
Mayerhöfer, T. G., Pahlow, S., Hübner, U., & Popp, J. (2018) · The Analyst · doi:10.1039/c8an00526e · Cited by 56
The Electric Field Standing Wave Effect in Infrared Transmission Spectroscopy
Mayerhöfer, T. G., Mutschke, H., & Popp, J. (2017) · ChemPhysChem · doi:10.1002/cphc.201700688 · Cited by 37
Metadata
- Authors
- Wrobel, T. P., Wajnchold, B., Byrne, H. J., & Baranska, M.
- Venue
- Vibrational Spectroscopy
- Publisher
- Elsevier BV
- Published
- 2013-11
- Volume
- 69
- Pages
- 84-92
- ISSN
- 0924-2031 (ISSN-L)
- OpenAlex
- W2034467974
- Cited by
- 35
- References
- 3
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.