Abstract
This review presents the current understanding of the factors influencing the quality of spectra recorded and the pre-processing steps commonly employed to improve on spectral quality, as well as some of the most common techniques for classification and analysis of the spectral data for biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 3 Example of mean spectra recorded on two different human skin samples from the thigh dry (A and B) and using the immersion objective (respectively C and D). The first sample has been dewaxed in hexane (A and D), the second using xylene (B and C). (Reproduced from John Wiley and Sons [34])](https://figures.cochat.ai/paper-figures/4a3c5a8b7cf1414fa50de3523dcea6d3/spectral-pre-and-post-processing-for-infrared-and-raman-spectroscopy-of-figure-3.png)


![Figure 5 I; (A) Microscopic image of an A549 cell, showing the reduced area identified for spectral mapping. (B) K-means cluster map of the Raman profile of the same reduced area. II; K-means spectra of clusters 3 (A - representing nucleoli), 6 (B - representing nucleus), 1 and 4 (C and D, both from the cytoplasm). Spectra are offset for clarity. III; K-means spectrum of Cluster 5 (A), compared to the Raman spectrum polystyrene nanoparticles (B). Spectra are offset for clarity. (Reproduced from Royal Society of Chemistry [12])](https://figures.cochat.ai/paper-figures/ca0de7f86c4046dab8b11f94112e3c5c/spectral-pre-and-post-processing-for-infrared-and-raman-spectroscopy-of-figure-5.png)


![Figure 7 Mean Raman spectra recorded from RNA (A), histone (B) and ceramide (C) on CaF2 windows. II: Scores plot of the 2 first principal components after PCA performed on Raman spectra recorded from RNA, histone and ceramide. III: Plot of the loadings of PC1 (blue dot line) compared with the difference spectrum calculated from the mean spectrum of ceramide minus the mean spectrum of RNA (red dash line). The loadings are compared with spectra recorded from ceramide (A) and RNA (C), both offset for clarity. IIIB: Plot of the loadings of PC2 (blue dot line) compared with the difference between the mean spectrum of histone minus the average mean spectrum of RNA and ceramide (red dash line). (Reproduced from Royal Society of Chemistry [89])](https://figures.cochat.ai/paper-figures/e74348b7ea37457fadb13ba234c1aec7/spectral-pre-and-post-processing-for-infrared-and-raman-spectroscopy-of-figure-7.png)

![Figure 9 SCCA analysis using component spectra of polystyrene (A), 3-sn-phosphatidyl ethanolamine (B) and RNA (C). The spectrum of each pure component is shown on the left of the figure and the correlation maps for non-thresholded shown in the middle and thresholded on the right. (Reproduced from Royal Society of Chemistry [13])](https://figures.cochat.ai/paper-figures/0d359cad7e084c7ebcfd2d887424f5ab/spectral-pre-and-post-processing-for-infrared-and-raman-spectroscopy-of-figure-9.png)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Hierarchical Grouping to Optimize an Objective Function
Ward, J. H. (1963) · Journal of the American Statistical Association · doi:10.1080/01621459.1963.10500845 · Cited by 20,598
Vertex component analysis: a fast algorithm to unmix hyperspectral data
Nascimento, J. M. P., & Dias, J. M. B. (2005) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2005.844293 · Cited by 2,669
Methods of multivariate analysis
(1995) · Choice Reviews Online · doi:10.5860/choice.33-1586 · Cited by 2,281
Data Mining and Knowledge Discovery Handbook
(2010) · doi:10.1007/978-0-387-09823-4 · Cited by 2,190
Advances in Neural Information Processing Systems 18
Murray, I., Mackay, D., Zoubin Ghahramani, A., & Skilling, J. (2006) · Cited by 1,927
Raman Spectroscopy for Chemical Analysis
McCreery, R. L. (2000) · Wiley eBooks · doi:10.1002/0471721646 · Cited by 1,440
Introduction to Multivariate Statistical Analysis in Chemometrics
Varmuza, K., & Filzmoser, P. (2016) · CRC Press eBooks · doi:10.1201/9781420059496 · Cited by 1,228
Studying single living cells and chromosomes by confocal Raman microspectroscopy
Puppels, G. J., de Mul, F. F. M., Otto, C., Greve, J., Robert-Nicoud, M., Arndt-Jovin, D. J., & Jovin, T. M. (1990) · Nature · doi:10.1038/347301a0 · Cited by 920
What Are Artificial Neural Networks?
Krogh, A. (2008) · Nature Biotechnology · doi:10.1038/nbt1386 · Cited by 844
Research works printed but not linked: 5
- H. J. Byrne , G. D.Sockalingum and N.Stone, in Biomedical Applications of Synchrotron Infrared Microspectroscopy: A Practical Approach, ed. D. Moss, RSC Analytical Spectroscopy Monographs No. 11, 2011, ISBN: 978-0-85404-154-1
- Huang, 2003, Int. J. Oncol., 23, 649
- K. H. Esbensen , Multivariate data analysis-in practice, CAMO Software AS, Norway, 2006
- K. Varmuza and P.Filzmoser, Introduction to Multivariate Statistical Analysis in Chemometrics, CRC Press, Taylor and Francis Group, Boca Raton, FL, 2009 · DOI · Paper page
- Meade, 2014, Proc. – IEEE Int. Conf. Bioinf. Biomed., 254
Cited by
Biomolecular and bioanalytical applications of infrared spectroscopy – A review
Beć, K. B., Grabska, J., & Huck, C. W. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.04.015 · Cited by 252
Clinical applications of infrared and Raman spectroscopy: state of play and future challenges
Baker, M. J., Byrne, H. J., Chalmers, J., Gardner, P., Goodacre, R., Henderson, A., Kazarian, S. G., Martin, F. L., Moger, J., Stone, N., et al. (2018) · The Analyst · doi:10.1039/c7an01871a · Cited by 230
Self-citationKrafft, C., Schmitt, M., Schie, I. W., Cialla‐May, D., Matthäus, C., Bocklitz, T., & Popp, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201607604 · Cited by 234
Raman microspectroscopy for microbiology
Lee, K. S., Landry, Z., Pereira, F. C., Wagner, M., Berry, D., Huang, W. E., Taylor, G. T., Kneipp, J., Popp, J., Zhang, M., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00075-6 · Cited by 161
Standardization of complex biologically derived spectrochemical datasets
Morais, C. L. M., Paraskevaidi, M., Li, C., Fullwood, N. J., Isabelle, M., Lima, K. M. G., Martin‐Hirsch, P. L., Sreedhar, H., Trevisan, J., Walsh, M. J., et al. (2019) · Nature Protocols · doi:10.1038/s41596-019-0150-x · Cited by 164
Metadata
- Authors
- Byrne, H. J., Knief, P., Keating, M. E., & Bonnier, F.
- Affiliations
- Dublin Institute of Technology (IE)
- Royal College of Surgeons in Ireland (IE)
- Université de Tours (FR)
- Corresponding author
- Byrne, Hugh J.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 45
- Issue
- 7
- Pages
- 1865-1878
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W1784804776
- Semantic Scholar
- 08f04a798d401ede390f5b05986d3bc923e16547
- Cited by
- 213
- References
- 104
- Citations by year
- 2026: 16 · 2025: 23 · 2024: 20 · 2023: 22 · 2022: 21 · 2021: 22 · 2020: 25 · 2019: 20 · 2018: 23 · 2017: 10 · 2016: 11
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- green
- arrow.tudublin.ie
- Licence
- cc-by-nc-sa
- Locations
- Chemical Society Reviews (publishedVersion)
- PubMed (publishedVersion)
- Arrow - TU Dublin (Technological University Dublin) (submittedVersion, cc-by-nc-sa)
- HAL (submittedVersion)
- Funders
- Science Foundation Ireland (11/PI/08)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- infrared spectroscopy, Raman spectroscopy, spectral preprocessing, biological tissue, biological cells, spectral distortion, sample presentation, measurement conditions, spectral classification, simulated spectra, disease diagnosis
- MeSH terms
- Cells, Humans, Spectrophotometry, Infrared, Spectrum Analysis, Raman, Biomedical Research
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spectral pre and post processing for infrared and Raman spectroscopy of biological tissues and cells. https://app.cochat.ai/papers/10.1039/c5cs00440c
- The paper
- Byrne, H. J., Knief, P., Keating, M. E., & Bonnier, F. (2016). Spectral pre and post processing for infrared and Raman spectroscopy of biological tissues and cells. Chemical Society Reviews. https://doi.org/10.1039/c5cs00440c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.