Biotransformation of arsenic species by activated sludge and removal of bio-oxidised arsenate from wastewater by coagulation with ferric chloride
Abstract
The potential of activated sludge to catalyse bio-oxidation of arsenite [As(III)] to arsenate [As(V)] and bio-reduction of As(V) to As(III) was investigated. In batch experiments (pH 7, 25 degrees C) using activated sludge taken from a treatment plant receiving municipal wastewater non-contaminated with As, As(III) and As(V) were rapidly biotransformed to As(V) under aerobic condition and As(III) under anaerobic one without acclimatisation, respectively. Sub-culture of the activated sludge using a minimal liquid medium containing 100mg As(III)/L and no organic carbon source showed that aerobic arsenic-resistant bacteria were present in the activated sludge and one of the isolated bacteria was able to chemoautotrophically oxidise As(III) to As(V). Analysis of arsenic species in a full-scale oxidation ditch plant receiving As-contaminated wastewater revealed that both As(III) and As(V) were present in the influent, As(III) was almost completely oxidised to As(V) after supply of oxygen by the aerator in the oxidation ditch, As(V) oxidised was reduced to As(III) in the anaerobic zone in the ditch and in the return sludge pipe, and As(V) was the dominant species in the effluent. Furthermore, co-precipitation of As(V) bio-oxidised by activated sludge in the plant with ferric hydroxide was assessed by jar tests. It was shown that the addition of ferric chloride to mixed liquor as well as effluent achieved high removal efficiencies (>95%) of As and could decrease the residual total As concentrations in the supernatant from about 200 microg/L to less than 5 microg/L. It was concluded that a treatment process combining bio-oxidation with activated sludge and coagulation with ferric chloride could be applied as an alternative technology to treat As-contaminated wastewater.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
For arsenic removal, Fe and Al based coagulants are widely used among the various chemical coagulants.
“For As removal, Fe and Al based coagulants are widely used [158] among the various chemical coagulants.”
From Arsenic Contamination of Groundwater: A Review of Sources, Prevalence, Health Risks, and Strategies for Mitigation (2014) · cites this paper as [158]
Cited by
Sorted by citations
A review on heavy metals (As, Pb, and Hg) uptake by plants through phytoremediation
Tangahu, B. V., Sheikh Abdullah, S. R., Basri, H., Idris, M., Anuar, N., & Mukhlisin, M. (2011) · International Journal of Chemical Engineering · doi:10.1155/2011/939161 · Cited by 1,684 · see citing works
Shankar, S., Shanker, U., & Shikha (2014) · The Scientific World Journal · doi:10.1155/2014/304524 · Cited by 616 · see citing works
“Fe based coagulants have also been investigated by several authors [162–165].”
Background
- Authors
- Andrianisa, H. A., Ito, A., Sasaki, A., Aizawa, J., & Umita, T.
- Affiliations
- Iwate University (JP)
- Yamagata University (JP)
- Corresponding author
- Ito, Ayumi
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2008-12
- Volume
- 42
- Issue
- 19
- Pages
- 4809-4817
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2026640016
- Cited by
- 75
- References
- 0
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 6 · 2022: 12 · 2021: 2 · 2020: 5 · 2019: 9 · 2018: 3 · 2017: 7 · 2016: 4 · 2015: 3 · 2014: 5 · 2013: 4 · 2012: 2
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Water Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Environmental Chemistry › Arsenic contamination and mitigation
- Physical Sciences › Environmental Science › Environmental Chemistry › Mine drainage and remediation techniques
- Physical Sciences › Environmental Science › Pollution › Wastewater Treatment and Nitrogen Removal
- Keywords
- arsenic biotransformation, arsenite oxidation, arsenate reduction, activated sludge, ferric chloride coagulation, oxidation ditch, aerobic and anaerobic conditions, arsenic-resistant bacteria, arsenic removal
- MeSH terms
- Arsenic, Biotransformation, Chlorides, Ferric Compounds, Oxidation-Reduction, Sewage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review