The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Removal of toxic metal ions with magnetic hydrogels
Open accessAbstract
Hydrogels, based on 2-acrylamido-2-methyl-1-propansulfonic acid (AMPS) were synthesized via photopolymerization technique and used for the preparation of magnetic responsive composite hydrogels. These composite hydrogels with magnetic properties were further utilized for the removal of toxic metal ions such as Cd(II), Co(II), Fe(II), Pb(II), Ni(II), Cu(II) and Cr(III) from aqueous environments. It was revealed that hydrogel networks with magnetic properties can effectively be utilized in the removal of pollutants. The results verified that magnetic iron particle containing p(AMPS) hydrogel networks provide advantageous over conventional techniques. Langmuir and Freundlich adsorption isotherms were applied for toxic metal removal and both isotherms were fit reasonably well for the metal ion absorptions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The adsorption of gases on plane surfaces of glass, mica and platinum
Langmuir, I. (1918) · Journal of the American Chemical Society · doi:10.1021/ja02242a004 · Cited by 23,242
Über die adsorption in lösungen
Freundlich, H. (1907) · Zeitschrift für Physikalische Chemie · doi:10.1515/zpch-1907-5723 · Cited by 9,001
Magnetic Chitosan Nanocomposites: A Useful Recyclable Tool for Heavy Metal Ion Removal
Liu, X., Hu, Q., Fang, Z., Zhang, X., & Zhang, B. (2009) · Langmuir · doi:10.1021/la802754t · Cited by 532
Zhou, L., Wang, Y., Liu, Z., & Huang, Q. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.04.078 · Cited by 505
Magnetic hydrogel nanocomposites for remote controlled pulsatile drug release
SATARKAR, N., & HILT, J. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.06.008 · Cited by 505
Liu, C., Bai, R., & San Ly, Q. (2008) · Water Research · doi:10.1016/j.watres.2007.10.031 · Cited by 446
Zhou, Y.-T., Nie, H.-L., Branford-White, C., He, Z.-Y., & Zhu, L.-M. (2009) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.10.026 · Cited by 421
Fuhrer, R., Athanassiou, E. K., Luechinger, N. A., & Stark, W. J. (2009) · Small · doi:10.1002/smll.200801091 · Cited by 296
Adsorption of lead and humic acid on chitosan hydrogel beads
Yan, W. L., & Bai, R. (2005) · Water Research · doi:10.1016/j.watres.2004.11.007 · Cited by 239
Kaşgöz, H., Durmuş, A., & Kaşgöz, A. (2008) · Polymers for Advanced Technologies · doi:10.1002/pat.999 · Cited by 233
Hydrogel nanocomposites as remote-controlled biomaterials
Satarkar, N. S., & Zach Hilt, J. (2008) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.07.009 · Cited by 214
Adsorptive features of chitosan entrapped in polyacrylamide hydrogel for Pb2+, UO22+, and Th4+
Akkaya, R., & Ulusoy, U. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.05.084 · Cited by 165
Preparation and lead ion removal property of hydroxyapatite/polyacrylamide composite hydrogels
Jang, S. H., Jeong, Y. G., Min, B. G., et al. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.02.018 · Cited by 163
Yetimoğlu, E. K., Kahraman, M. V., Ercan, Ö., Akdemir, Z. S., & Apohan, N. K. (2007) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2007.02.007 · Cited by 154
Diethylenetriamine-grafted poly(glycidyl methacrylate) adsorbent for effective copper ion adsorption
Liu, C., Bai, R., & Hong, L. (2006) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2006.07.057 · Cited by 153
Zhao, L., & Mitomo, H. (2008) · Journal of Applied Polymer Science · doi:10.1002/app.28718 · Cited by 146
Gad, Y. H. (2008) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2008.05.002 · Cited by 137
Wei, L., Yang, G., Wang, R., & Ma, W. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.09.016 · Cited by 105
Guilherme, M. R., Reis, A. V., Paulino, A. T., Fajardo, A. R., Muniz, E. C., & Tambourgi, E. B. (2007) · Journal of Applied Polymer Science · doi:10.1002/app.26287 · Cited by 105
Hernández, R., & Mijangos, C. (2008) · Macromolecular Rapid Communications · doi:10.1002/marc.200800602 · Cited by 97
Şahiner, N. (2006) · Colloid & Polymer Science · doi:10.1007/s00396-006-1562-z · Cited by 96
Dual thermo-responsive and ion-recognizable monodisperse microspheres
Ju, X., Liu, L., Xie, R. S., et al. (2008) · Polymer · doi:10.1016/j.polymer.2008.12.022 · Cited by 80
Iemma, F., Cirillo, G., Spizzirri, U. G., Puoci, F., Parisi, O. I., & Picci, N. (2008) · European Polymer Journal · doi:10.1016/j.eurpolymj.2008.01.024 · Cited by 58
Preparation and swelling characterization of poly (n‐isopropylacrylamide)‐based porous hydrogels
Chern, J., Lee, W., & Hsieh, M. (2004) · Journal of Applied Polymer Science · doi:10.1002/app.20301 · Cited by 32
Taleb, M. F. A., Elsigeny, S. M., & Ibrahim, M. M. (2007) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2007.02.008 · Cited by 16
Cited by
Water purification using magnetic assistance: A review
Ambashta, R. D., & Sillanpää, M. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.04.105 · Cited by 977
Thoniyot, P., Tan, M. J., Karim, A. A., Young, D. J., & Loh, X. J. (2015) · Advanced Science · doi:10.1002/advs.201400010 · Cited by 928
Badruddoza, A. Z. M., Shawon, Z. B. Z., Tay, W. J. D., Hidajat, K., & Uddin, M. S. (2013) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2012.08.030 · Cited by 636
Badruddoza, A. Z. M., Tay, A. S. H., Tan, P. Y., Hidajat, K., & Uddin, M. S. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.10.029 · Cited by 572
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
Metadata
- Authors
- Ozay, O., Ekici, S., Baran, Y., Aktas, N., & Sahiner, N.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2009-09
- Volume
- 43
- Issue
- 17
- Pages
- 4403-4411
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2026816247
- Cited by
- 412
- References
- 25
- FWCI
- 20.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.