Quantification of continual anthropogenic pollutants released in swimming pools
Abstract
Disinfection in swimming pools is often performed by chlorination, However, anthropogenic pollutants from swimmers will react with chlorine and form disinfection by-products (DBPs). DBPs are unwanted from a health point of view, because some are irritating, while others might be carcinogenic. The reduction of anthropogenic pollutants will lead to a reduction in DBPs. This paper investigates the continual release of anthropogenic pollutants by means of controlled sweat experiments in a pool tank during laboratory time-series experiments (LTS experiments) and also during on-site experiments (OS experiments) in a swimming pool. The sweat released during the OS and LTS experiments was very similar. The sweat rate found was 0.1-0.2 L/m(2)/h at water temperatures below 29 °C and increased linearly with increasing water temperatures to 0.8 L/m(2)/h at 35 °C. The continual anthropogenic pollutant release (CAPR) not only consisted of sweat, particles (mainly skin fragments and hair) and micro-organisms, but also sebum (skin lipids) has to be considered. The release of most components can be explained by the composition of sweat. The average release during 30 min of exercise is 250 mg/bather non-purgeable organic carbon (NPOC), 77.3 mg/bather total nitrogen (TN), 37.1 mg/bather urea and 10.1 mg/bather ammonium. The release of NPOC cannot be explained by the composition of sweat and is most probably a result of sebum release. The average release of other components was 1.31 × 10(9) # particles/bather (2-50 μm), 5.2 μg/bather intracellular adenosine triphosphate (cATP) and 9.3 × 10(6) intact cell count/bather (iCC). The pool water temperature was the main parameter to restrain the CAPR. This study showed that a significant amount of the total anthropogenic pollutants release is due to unhygienic behaviour of bathers.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The average release of pollutants during 30 min exercise is 250, 77.3, 37.1 and 10.1 mg/bather for non-purgeable organic carbon, total nitrogen, urea and ammonium, respectively.
“The average release of pollutants during 30 min exercise is 250, 77.3, 37.1 and 10.1 mg/bather for non-purgeable organic carbon, TN, urea and ammonium, respectively (Keuten et al., 2014).”
From Regulation, formation, exposure, and treatment of disinfection by-products (DBPs) in swimming pool waters: A critical review (2018) · cites this paper as Keuten et al., 2014
The elimination of unhygienic behaviour has been shown to reduce disinfection by-product formation by 55% at 35 °C and up to 68% at 25 °C, and these proportions are expected to increase at lower exercise levels.
“The elimination of unhygienic behaviour has been shown to reduce the DBP formation by 55% in 35 °C and up to 68% in 25 °C, and these proportions are expected to increase at lower exercise levels (Keuten et al., 2014).”
From Regulation, formation, exposure, and treatment of disinfection by-products (DBPs) in swimming pool waters: A critical review (2018) · cites this paper as Keuten et al., 2014
Cites
Richardson, S. D., DeMarini, D. M., Kogevinas, M., Fernandez, P., Marco, E., Lourencetti, C., Ballesté, C., Heederik, D., Meliefste, K., McKague, A. B., et al. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.1001965 · Cited by 327 · see citing works
Exposure to chloramines in the atmosphere of indoor swimming pools
HERY, M. (1995) · The Annals of Occupational Hygiene · doi:10.1016/0003-4878(95)00013-5 · Cited by 167 · see citing works
Genotoxic effects in swimmers exposed to disinfection by-products in indoor swimming pools
Kogevinas, M., Villanueva, C. M., Font-Ribera, L., Liviac, D., Bustamante, M., Espinoza, F., Nieuwenhuijsen, M. J., Espinosa, A., Fernandez, P., DeMarini, D. M., et al. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.1001959 · Cited by 144 · see citing works
Short-Term Changes in Respiratory Biomarkers after Swimming in a Chlorinated Pool
Font-Ribera, L., Kogevinas, M., Zock, J.-P., Gómez, F. P., Barreiro, E., Nieuwenhuijsen, M. J., Fernandez, P., Lourencetti, C., Pérez-Olabarría, M., Bustamante, M., et al. (2010) · Environmental Health Perspectives · doi:10.1289/ehp.1001961 · Cited by 119 · see citing works
The good, the bad, and the volatile: can we have both healthy pools and healthy people?
LaKind, J. S., Richardson, S. D., & Blount, B. C. (2010) · Environmental Science & Technology · doi:10.1021/es903241k · Cited by 82 · see citing works
Lahl, U., Bätjer, K., Düszeln, J. V., Gabel, B., Stachel, B., & Thiemann, W. (1981) · Water Research · doi:10.1016/0043-1354(81)90133-0 · Cited by 77 · see citing works
Body mass changes and voluntary fluid intakes of elite level water polo players and swimmers
Cox, G., Broad, E., Riley, M., & Burke, L. (2002) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(02)80003-2 · Cited by 66 · see citing works
Dietary intervention and training in swimmers
Cade, J. R., Reese, R. H., Privette, R. M., Hommen, N. M., Rogers, J. L., & Fregly, M. J. (1991) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00233850 · Cited by 40 · see citing works
Effects of three different water temperatures on dehydration in competitive swimmers
Macaluso, F., Di Felice, V., Boscaino, G., Bonsignore, G., Stampone, T., Farina, F., & Morici, G. (2011) · Science & Sports · doi:10.1016/j.scispo.2010.10.004 · Cited by 32 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Yang, L., Chen, X., She, Q., Cao, G., Liu, Y., Chang, V. W.-C., & Tang, C. Y. (2018) · Environment International · doi:10.1016/j.envint.2018.10.024 · Cited by 144 · see citing works
- Authors
- Keuten, M. G. A., Peters, M. C. F. M., Daanen, H. A. M., de Kreuk, M. K., Rietveld, L. C., & van Dijk, J. C.
- Affiliations
- Delft University of Technology (NL)
- Netherlands Organisation for Applied Scientific Research (NL)
- Corresponding author
- Keuten, M.G.A.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2014-04
- Volume
- 53
- Pages
- 259-270
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2068175550
- Cited by
- 74
- References
- 9
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 3 · 2023: 6 · 2022: 7 · 2021: 7 · 2020: 4 · 2019: 9 · 2018: 9 · 2017: 11 · 2016: 3 · 2015: 5 · 2014: 4
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Water Research (publishedVersion)
- PubMed (publishedVersion)
- TNO Repository (submittedVersion)
- VU Research Portal (submittedVersion)
- Repository hosted by TU Delft Library (TU Delft) (submittedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Funders
- Technische Universiteit Delft
- Agentschap NL
- European Regional Development Fund
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Water Treatment and Disinfection
- Physical Sciences › Environmental Science › Water Science and Technology › Fecal contamination and water quality
- Physical Sciences › Environmental Science › Water Science and Technology › Advanced oxidation water treatment
- Keywords
- swimming pools, anthropogenic pollutants, disinfection by-products, chlorination, sweat, sebum, non-purgeable organic carbon, urea, ammonium, total nitrogen, ATP, water temperature, pollutant release
- MeSH terms
- Disinfectants, Environmental Monitoring, Humans, Sweating, Swimming Pools, Temperature, Water Pollutants, Chemical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review