The DOI matches its Crossref record.
Membrane technology costs and me
Open accessAbstract
A reflection of the place cost analysis holds in membrane process technology research and development is provided. The review encompassed two membrane processes and applications: (a) reverse osmosis (RO) for seawater desalination, and (b) membrane bioreactor (MBR) technology for wastewater treatment. The cost analysis undertaken extended to (i) the determination of operating expenditure (OPEX) trends using simple analytical expressions, (ii) the subsequent estimation of the sensitivity of OPEX to individual system parameters, and (iii) published data on CAPEX for individual full-scale installations or from cost analyses. An appraisal of the peer-reviewed literature through a survey of a leading scientific database was also carried out. This bibliometric analysis was based on authors' keywords; it aimed to establish the profile of process cost for each of the two applications when compared with other popular research topics. The OPEX analysis, ostensibly through a consideration of specific energy demand in kWh per m3 permeate, revealed it to relate primarily to hydrodynamics in the case of RO, and to both membrane fouling and air scouring for MBRs. The bibliometric analysis of research trends revealed a marked difference in emphasis on cost aspects between the two research areas, with the focus on cost specifically being 16 times greater for RO desalination of seawater than MBR treatment of wastewater. MBR research appears to be dominated by fouling and foulant characterisation, making up almost a quarter of all studies, notwithstanding evidence from practitioners that other process parameters are as important in determining MBR process OPEX and operability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gravity-driven membrane filtration for water and wastewater treatment: A review
Pronk, W., Ding, A., Morgenroth, E., Derlon, N., Desmond, P., Burkhardt, M., Wu, B., & Fane, A. G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.062 · Cited by 455
Desalination of Water: a Review
Darre, N. C., & Toor, G. S. (2018) · Current Pollution Reports · doi:10.1007/s40726-018-0085-9 · Cited by 352
Comparison of energy consumption in desalination by capacitive deionization and reverse osmosis
Qin, M., Deshmukh, A., Epsztein, R., Patel, S. K., Owoseni, O. M., Walker, W. S., & Elimelech, M. (2019) · Desalination · doi:10.1016/j.desal.2019.01.003 · Cited by 292
Photosynthetic bacteria wastewater treatment with the production of value-added products: a review
Cao, K., Zhi, R., & Zhang, G. (2020) · Bioresource Technology · doi:10.1016/j.biortech.2019.122648 · Cited by 110
Metadata
- Authors
- Judd, S. J.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 122
- Pages
- 1-9
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2615664361
- Cited by
- 188
- References
- 0
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Membrane technology costs and me. https://app.cochat.ai/papers/10.1016/j.watres.2017.05.027
- The paper
- Judd, S. J. (2017). Membrane technology costs and me. Water Research. https://doi.org/10.1016/j.watres.2017.05.027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.