Review on low- and high-frequency sonolytic, sonophotolytic and sonophotochemical processes for inactivating pathogenic microorganisms in aqueous media
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Ultraviolet and ultrasound-based advanced oxidation processes (AOPs) are gaining considerable research attention for water treatment and disinfection. Compared to low-frequency ultrasound (LFUS, <100 kHz), high-frequency ultrasound (HFUS, >100 kHz and MHz range) for water disinfection remains much less investigated. The present review aims at surveying and discussing literature data on microbial inactivation in non-food aqueous media using HFUS alone and with AOPs. More specifically, the review covers sonophotolytic (US/UV) processes under sequential and simultaneous modes as well as sonophotochemical processes, where both low and high frequencies were applied. Addressing a state-of-the-art biomedical research, we have attempted to provide more insight into mechanical and sonochemical mechanisms of inactivation under ultrasonic exposure. Sonoporation, intracellular generation of reactive oxygen species (ROS), energy stimulation of aquaporins to deliver ROS, and injection of extracellular ROS into sonoporated cells have all been identified as primary ways of inactivation. Application of ultrasound in the 0.2-2 MHz range and mercury-free light sources to support the Minamata Convention on Mercury is an ongoing challenge for effective elimination of microbial pathogens from water and wastewater through sonophotolytic and sonophotochemical AOPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UV-induced DNA damage and repair: a review
Sinha, R. P., & Häder, D.-P. (2002) · Photochemical & Photobiological Sciences · doi:10.1039/b201230h · Cited by 1,978
Sulfate Radical and Its Application in Decontamination Technologies
Zhang, B.-T., Zhang, Y., Teng, Y., & Fan, M. (2015) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2014.970681 · Cited by 536
Degradation of pharmaceuticals by ultrasound-based advanced oxidation process
Rayaroth, M. P., Aravind, U. K., & Aravindakumar, C. T. (2016) · Environmental Chemistry Letters · doi:10.1007/s10311-016-0568-0 · Cited by 182
Cited by
Abdurahman, M. H., Abdullah, A. Z., & Shoparwe, N. F. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127412 · Cited by 408
Advanced oxidation processes for water disinfection: Features, mechanisms and prospects
Chen, Y.-D., Duan, X., Zhou, X., Wang, R., Wang, S., Ren, N.-Q., & Ho, S.-H. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.128207 · Cited by 374
Abdi, J., Sisi, A. J., Hadipoor, M., & Khataee, A. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.127558 · Cited by 144
Wang, G., Wu, W., Zhu, J.-J., & Peng, D. (2021) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2021.105781 · Cited by 61
Kang, Z., Yang, M., Feng, X., Liao, H., Zhang, Z., & Du, Y. (2022) · International Journal of Nanomedicine · doi:10.2147/ijn.s360161 · Cited by 21
“The reason may be related to the fact that nanoparticles can increase the acoustic cavitation effect and induce stronger sonochemical reactions to enhance the efficiency of ROS generation.(46) Investigation into the possible mechanisms revealed that sonodynamically induced reactive oxygen species and hydroxyl radical…”
Background
Metadata
- Authors
- Matafonova, G., & Batoev, V.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 166
- Pages
- 115085
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W2972478193
- Cited by
- 85
- References
- 3
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Review on low- and high-frequency sonolytic, sonophotolytic and sonophotochemical processes for inactivating pathogenic microorganisms in aqueous media. https://app.cochat.ai/papers/10.1016/j.watres.2019.115085
- The paper
- Matafonova, G., & Batoev, V. (2019). Review on low- and high-frequency sonolytic, sonophotolytic and sonophotochemical processes for inactivating pathogenic microorganisms in aqueous media. Water Research. https://doi.org/10.1016/j.watres.2019.115085
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.