The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Oxidation of tetracycline and oxytetracycline for the photo-Fenton process: Their transformation products and toxicity assessment
Open accessAbstract
Advanced oxidation processes have gained significant attention for treating tetracycline (TC) and oxytetracycline (OTC), however, their oxidation using the photo-Fenton process has not been sufficiently studied. Although degradations of TC and OTC were enhanced by increasing H2O2 and Fe2+ within the ranges investigated (H2O2 = 20-50 mg/L and Fe = 1-10 mg/L) under UV irradiation, further experiments for the photo-Fenton process were conducted with 20 mg/L of H2O2 and 5 mg/L of Fe2+ to balance efficiency and cost. The photo-Fenton process (UV/H2O2/Fe2+) was shown to be more effective to remove TC and OTC than H2O2, ultraviolet (UV), and UV/H2O2 at the same doses of oxidants. Inorganic anions and cations were shown to inhibit the degradation of TC and OTC during the photo-Fenton process, in the following order: HPO42- > HCO3- ≫ SO42- > Cl- and Cu2+ ≫ Ca2+ > Na+. The TC and OTC degradation are generally improved by increasing pH, which is opposite to the kpCBA,obs values, caused by increasing the deprotonation degree of TC and OTC. Four and nine transformation products of TC and OTC, respectively, were detected over the treatment period. Among the transformation products, m/z 443.14 (C22H22N2O8) formed during TC degradation, and m/z 433.16 (C20H20N2O9) and m/z 415.15 (C20H18N2O8) formed during OTC degradation, were reported for the first time. Vibrio fischeri toxicity assessment indicated that the inhibition ratio was decreased with a decreasing TC concentration, while, OTC transformation lead to higher toxicity. The product (m/z 477.15b) was determined to be the compound causing toxicity during degradation of OTC by using the quantitative structure activity relationship (QSAR). This toxic transformation product caused higher inhibition ratios than its parental compound (OTC), but its further oxidization resulted in decreasing the inhibition ratios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Sarmah, A. K., Meyer, M. T., & Boxall, A. B. A. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2006.03.026 · Cited by 3,326
Removal of residual pharmaceuticals from aqueous systems by advanced oxidation processes
Klavarioti, M., Mantzavinos, D., & Kassinos, D. (2009) · Environment International · doi:10.1016/j.envint.2008.07.009 · Cited by 1,825
Watkinson, A. J., Murby, E. J., & Costanzo, S. D. (2007) · Water Research · doi:10.1016/j.watres.2007.04.005 · Cited by 1,197
Rate constants for reaction of hydroxyl radicals with several drinking water contaminants
Haag, W. R., & Yao, C. C. D. (1992) · Environmental Science & Technology · doi:10.1021/es00029a021 · Cited by 828
Wang, J., Zhi, D., Zhou, H. S., He, X., & Zhang, D. (2018) · Water Research · doi:10.1016/j.watres.2018.03.030 · Cited by 747
Removal of pharmaceuticals from water by homo/heterogonous Fenton-type processes – A review
Mirzaei, A., Chen, Z., Haghighat, F., & Yerushalmi, L. (2017) · Chemosphere · doi:10.1016/j.chemosphere.2017.02.019 · Cited by 600
The photolysis of hydrogen peroxide at high light intensities
Baxendale, J. H., & Wilson, J. A. (1957) · Transactions of the Faraday Society · doi:10.1039/tf9575300344 · Cited by 561
Batt, A. L., Kim, S., & Aga, D. S. (2007) · Chemosphere · doi:10.1016/j.chemosphere.2007.01.008 · Cited by 542
Self-citationReactions of hydroxyl radicals with hydrogen peroxide at ambient and elevated temperatures
Christensen, H., Sehested, K., & Corfitzen, H. (1982) · The Journal of Physical Chemistry · doi:10.1021/j100206a023 · Cited by 514
Cited by
Xu, L., Zhang, H., Xiong, P., Zhu, Q., Liao, C., & Jiang, G. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.141975 · Cited by 1,206
Zhou, X., Zhu, Y., Niu, Q., Zeng, G., Lai, C., Liu, S., Huang, D., Qin, L., Liu, X., Li, B., et al. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.129027 · Cited by 319
Metadata
- Authors
- Han, C.-H., Park, H.-D., Kim, S.-B., Yargeau, V., Choi, J.-W., Lee, S.-H., & Park, J.-A.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 172
- Pages
- 115514
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W3000690207
- Cited by
- 323
- References
- 48
- FWCI
- 13.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxidation of tetracycline and oxytetracycline for the photo-Fenton process: Their transformation products and toxicity assessment. https://app.cochat.ai/papers/10.1016/j.watres.2020.115514
- The paper
- Han, C.-H., Park, H.-D., Kim, S.-B., Yargeau, V., Choi, J.-W., Lee, S.-H., & Park, J.-A. (2020). Oxidation of tetracycline and oxytetracycline for the photo-Fenton process: Their transformation products and toxicity assessment. Water Research. https://doi.org/10.1016/j.watres.2020.115514
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.