The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Membrane fouling caused by biological foams in a submerged membrane bioreactor: Mechanism insights
Abstract
Though sludge foaming often occurs and thus causes serious membrane fouling in membrane bioreactors (MBRs), the fouling mechanisms related with the foaming phenomenon have not been well addressed, hindering better understanding and solving foaming problem. In this work, it was interestingly found that, the foulants during the foaming period possessed extremely high specific filtration resistance (SFR) (over 1016 m kg-1) and strong adhesion ability to membrane surface. Chemical characterization showed that the proteins (178.57 mg/L) and polysaccharides (209.21 mg/L) in the foaming sample were about 6.4 times and 5.4 times of those in the supernatant sample, suggesting existence of a mechanism permitting continuous production of these foulants in the MBR during the foaming period. It was revealed that the fouling caused by foams was associated with gel layer filtration process, and the extremely high SFR can be interpreted by chemical potential change in the gel filtration process depicted in Flory-Huggins theory. Meanwhile, analyses by the extended Derjaguin-Landau-Verwey-Overbeek (XDLVO) theory showed that the strong adhesion ability stemmed from the high interaction energy between the foaming foulants and membrane surface. In addition, 16S rDNA gene sequencing identified that the abundance of the foaming related bacteria species in the sludge suspension during the foaming period was more than 10 times of that during the non-foaming period. This study offered new mechanism insights into foaming fouling in MBRs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PROTEIN MEASUREMENT WITH THE FOLIN PHENOL REAGENT
Lowry, O., Rosebrough, N., Farr, A. L., & Randall, R. (1951) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)52451-6 · Cited by 317,331
Colorimetric Method for Determination of Sugars and Related Substances
DuBois, M., Gilles, K. A., Hamilton, J. K., Rebers, P. A., & Smith, F. (1956) · Analytical Chemistry · doi:10.1021/ac60111a017 · Cited by 52,269
Thermodynamics of High Polymer Solutions
Flory, P. J. (1942) · The Journal of Chemical Physics · doi:10.1063/1.1723621 · Cited by 4,374
Some Properties of Solutions of Long-chain Compounds.
Huggins, M. L. (1942) · The Journal of Physical Chemistry · doi:10.1021/j150415a018 · Cited by 1,350
Constant Pressure Blocking Filtration Law Application to Powder-Law Non-Newtonian Fluid
Hermia, J. (1982) · Digital Access to Libraries · Cited by 1,193
Fouling in membrane bioreactors: An updated review
Meng, F., Zhang, S., Oh, Y., Zhou, Z., Shin, H.-S., & Chae, S.-R. (2017) · Water Research · doi:10.1016/j.watres.2017.02.006 · Cited by 1,078
Acid—base interfacial interactions in aqueous media
van Oss, C. J. (1993) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(93)80308-2 · Cited by 938
Membrane cleaning in membrane bioreactors: A review
Wang, Z., Ma, J., Tang, C. Y., Kimura, K., Wang, Q., & Han, X. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.05.060 · Cited by 821
Lin, H., Zhang, M., Wang, F., Meng, F., Liao, B.-Q., Hong, H., Chen, J., & Gao, W. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.02.034 · Cited by 764
Self-citationHydrophobicity of biosurfaces — Origin, quantitative determination and interaction energies
van Oss, C. J. (1995) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/0927-7765(95)01217-7 · Cited by 574
Cited by
Applications of tannic acid in membrane technologies: A review
Yan, W., Shi, M., Dong, C., Liu, L., & Gao, C. (2020) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2020.102267 · Cited by 473
Mahto, K. U., Vandana, Priyadarshanee, M., Samantaray, D. P., & Das, S. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.134759 · Cited by 326
Deng, Y., Zhou, X., Shen, J., Xiao, G., Hong, H., Lin, H., Wu, F., & Liao, B.-Q. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.145534 · Cited by 302
Self-citation
Metadata
- Authors
- Wu, M., Chen, Y., Lin, H., Zhao, L., Shen, L., Li, R., Xu, Y., Hong, H., & He, Y.
- Venue
- Water Research
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 181
- Pages
- 115932
- ISSN
- 0043-1354 (ISSN-L)
- OpenAlex
- W3025754501
- Cited by
- 260
- References
- 20
- FWCI
- 15.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Membrane fouling caused by biological foams in a submerged membrane bioreactor: Mechanism insights. https://app.cochat.ai/papers/10.1016/j.watres.2020.115932
- The paper
- Wu, M., Chen, Y., Lin, H., Zhao, L., Shen, L., Li, R., Xu, Y., Hong, H., & He, Y. (2020). Membrane fouling caused by biological foams in a submerged membrane bioreactor: Mechanism insights. Water Research. https://doi.org/10.1016/j.watres.2020.115932
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.