Point of Care Nucleic Acid Testing for SARS-CoV-2 in Hospitalized Patients: A Clinical Validation Trial and Implementation Study
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Abstract Background There is urgent need for safe and efficient triage protocols for hospitalized COVID-19 suspects to appropriate isolation wards. A major barrier to timely discharge of patients from the emergency room and hospital is the turnaround time for many SARS-CoV-2 nucleic acid tests. We validated a point of care nucleic acid amplification based platform SAMBA II for diagnosis of COVID-19 and performed an implementation study to assess its impact on patient disposition at a major academic hospital. Methods We prospectively recruited COVID-19 suspects admitted to hospital ( NCT04326387 ). In an initial pilot phase, individuals were tested using a nasal/throat swab with the SAMBA II SARS-CoV-2 rapid diagnostic platform in parallel with a combined nasal/throat swab for standard central laboratory RT-PCR testing. In the second implementation phase, we examined the utility of adding the SAMBA platform to routine care. In the pilot phase, we measured concordance and assay validity using the central laboratory as the reference standard and assessed assay turnaround time. In the implementation phase, we assessed 1) time to definitive bed placement from admission, 2) time spent on COVID-19 holding wards, 3) proportion of patients in isolation versus COVID negative areas following a test, comparing the implementation phase with the 10 days prior to implementation. Results In phase I, 149 participants were included in the pilot. By central laboratory RT-PCR testing, 32 (21.5%) tested positive and 117 (78.5%). Sensitivity and specificity of the SAMBA assay compared to RT-PCR lab test were 96.9% (95% CI 0.838-0.999) and 99.1% (0.953-0.999), respectively. Median time to result was 2.6 hours (IQR 2.3 to 4.8) for SAMBA II SARS-CoV-2 test and 26.4 hours (IQR 21.4 to 31.4) for the standard lab RT-PCR test (p<0.001). In the first 10 days of the SAMBA implementation phase, we conducted 992 tests, with the majority (59.8%) used for hospital admission, and the remainder for pre-operative screening (11.3%), discharge planning (10%), in-hospital screening of new symptoms (9.7%). Comparing the pre-implementation (n=599) with the implementation phase, median time to definitive bed placement from admission was reduced from 23.4 hours (8.6-41.9) to 17.1 hours (9.0-28.8), P =0.02 in Cox analysis, adjusted for age, sex, comorbidities and clinical severity at presentation. Mean length of stay on a COVID-19 ‘holding’ ward decreased from 58.5 hours to 29.9 hours ( P <0.001). Use of single occupancy rooms amongst those tested fell from 30.8% before to 21.2% ( P =0.03) and 11 hospital bay closures (on average 6 beds each) were avoided after implementation of the POC assay. Conclusions The SAMBA II SARS-CoV-2 rapid assay performed well compared to a centralized laboratory RT-PCR platform and demonstrated shorter time to result both in trial and real-world settings. It was also associated with faster time to definitive bed placement from the emergency room, greater availability of isolation rooms, avoidance of hospital bay closures, and greater movement of patients to COVID negative open “green” category wards. Rapid testing in hospitals has the potential to transform ability to deal with the COVID-19 epidemic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Docherty, A. B., Harrison, E. M., Green, C. A., Hardwick, H. E., Pius, R., Norman, L., Holden, K. A., Read, J. M., Dondelinger, F., Carson, G., et al. (2020) · BMJ · doi:10.1136/bmj.m1985 · Cited by 3,481
Antibody responses to SARS-CoV-2 in patients with COVID-19
Long, Q.-X., Liu, B.-Z., Deng, H.-J., Wu, G.-C., Deng, K., Chen, Y.-K., Liao, P., Qiu, J.-F., Lin, Y., Cai, X.-F., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0897-1 · Cited by 2,876 · cited 1×
“It is well known that the diagnosis of COVID-19 is complicated in a number of patients who have negative PCR nose and throat swabs, frequently after the first week of illness, when SARS-CoV-2 antibody responses become detectable.(4) In the remaining 121 (21.”
BackgroundAntibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease 2019
Zhao, J., Yuan, Q., Wang, H., Liu, W., Liao, X., Su, Y., Wang, X., Yuan, J., Li, T., Li, J., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa344 · Cited by 2,607 · cited 1×
“It should also be borne in mind that nucleic acid tests on nose and throat swabs can be negative in COVID-19 disease, particularly when presentation to the hospital occurs beyond 7 days.(26) However, for general hospital infection control purposes, nose and throat nucleic acid detection is seen to be appropriate for i…”
BackgroundNepogodiev, D., Bhangu, A., Glasbey, J. C., Li, E., Omar, O. M., Simoes, J. F., Abbott, T. E., Alser, O., Arnaud, A. P., Bankhead-Kendall, B. K., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)31182-x · Cited by 1,711
Self-citationViral load of SARS-CoV-2 in clinical samples.
Pan, Y., Zhang, D., Yang, P., Poon, L. L. M., & Wang, Q. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30113-4 · Cited by 1,562 · cited 2×
“Current clinical testing for acute SARS-CoV-2 infection and infection risk relies on nucleic acid detection using reverse transcription polymerase chain reaction (RT-PCR) on nose and throat swabs.(2,3) Antibodies to SARS-CoV-2 are detectable in only 50% by days 5–7(4) and are therefore not suitable as a test for early…”
BackgroundMethodIntensive care management of coronavirus disease 2019 (COVID-19): challenges and recommendations
Phua, J., Weng, L., Ling, L., Egi, M., Lim, C.-M., Divatia, J. V., Shrestha, B. R., Arabi, Y. M., Ng, J., Gomersall, C. D., et al. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30161-2 · Cited by 1,509
Cited by
SARS-CoV-2 evolution during treatment of chronic infection
Kemp, S. A., Collier, D. A., Datir, R. P., Ferreira, I. A. T. M., Gayed, S., Jahun, A., Hosmillo, M., Rees-Spear, C., Mlcochova, P., Lumb, I. U., et al. (2021) · Nature · doi:10.1038/s41586-021-03291-y · Cited by 1,097
Self-citationRapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infection
Dinnes, J., Deeks, J. J., Berhane, S., Taylor, M., Adriano, A., Davenport, C., Dittrich, S., Emperador, D., Takwoingi, Y., Cunningham, J., et al. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013705.pub2 · Cited by 591
Bergamaschi, L., Mescia, F., Turner, L., Hanson, A. L., Kotagiri, P., Dunmore, B. J., Ruffieux, H., De Sa, A., Huhn, O., Morgan, M. D., et al. (2021) · Immunity · doi:10.1016/j.immuni.2021.05.010 · Cited by 338
Self-citationSoltan, A. A. S., Yang, J., Pattanshetty, R., Novak, A., Yang, Y., Rohanian, O., Beer, S., Soltan, M. A., Thickett, D. R., Fairhead, R., et al. (2022) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00272-7 · Cited by 54
Metadata
- Authors
- Collier, D. A., Assennato, S. M., Warne, B., Sithole, N., Sharrocks, K., Ritchie, A., Ravji, P., Routledge, M., Sparkes, D., Skittrall, J., Smielewska, A., Ramsey, I., Goel, N., Curran, M., Enoch, D., Tassell, R., Lineham, M., Vaghela, D., Leong, C., Mok, H. P., Bradley, J., Smith, K. G. C., Mendoza, V., Demiris, N., Besser, M., Dougan, G., Lehner, P. J., Siedner, M. J., Zhang, H., Waddington, C. S., Lee, H., Gupta, R. K., Baker, S., Bradley, J., Dougan, G., Goodfellow, I., Gupta, R. K., Lehner, P. J., Lyons, P., Matheson, N. J., Smith, K. G. C., Toshner, M., Weekes, M. P., Brown, N., Curran, M., Palmar, S., Zhang, H., Enoch, D., Chapman, D., Shaw, A., Mendoza, V., Jose, S., Bermperi, A., Zerrudo, J. A., Kourampa, E., Saunders, C., de Jesus, R., Domingo, J., Pasquale, C., Vergese, B., Vargas, P., Fabiculana, M., Perales, M., Skells, R., Mynott, L., Blake, E., Bates, A., Vallier, A.-L., Williams, A., Phillips, D., Chiu, E., Overhill, A., Ramenante, N., Sipple, J., Frost, S., Knock, H., Hardy, R., Foster, E., Davidson, F., Rundell, V., Bundi, P., Abeseabe, R., Clark, S., & Vicente, I.
- Venue
- Cell Reports Medicine
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 1
- Issue
- 5
- Pages
- 100062
- ISSN
- 2666-3791 (ISSN-L)
- OpenAlex
- W3042612346
- Cited by
- 53
- References
- 6
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Point of Care Nucleic Acid Testing for SARS-CoV-2 in Hospitalized Patients: A Clinical Validation Trial and Implementation Study. https://app.cochat.ai/papers/10.1016/j.xcrm.2020.100062
- The paper
- Collier, D. A., Assennato, S. M., Warne, B., Sithole, N., Sharrocks, K., Ritchie, A., Ravji, P., Routledge, M., Sparkes, D., Skittrall, J., Smielewska, A., Ramsey, I., Goel, N., Curran, M., Enoch, D., Tassell, R., Lineham, M., Vaghela, D., Leong, C., . . . Vicente, I. (2020). Point of Care Nucleic Acid Testing for SARS-CoV-2 in Hospitalized Patients: A Clinical Validation Trial and Implementation Study. Cell Reports Medicine. https://doi.org/10.1016/j.xcrm.2020.100062
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.